Multichannel SPR biosensor for detection of endocrine-disrupting compounds

被引:47
作者
Dostalek, J.
Pribyl, J.
Homola, J.
Skladal, P.
机构
[1] Acad Sci Czech Republic, Inst Photon & Elect, CR-18251 Prague, Czech Republic
[2] Masaryk Univ, Natl Ctr Biomol Res, CR-61137 Brno, Czech Republic
[3] Masaryk Univ, Dept Biochem, CR-61137 Brno, Czech Republic
关键词
surface plasmon resonance; Immunoassays; optical sensors; ELISA; pesticides; endocrine disruptors;
D O I
10.1007/s00216-007-1536-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A surface plasmon resonance (SPR) biosensor for simultaneous detection of multiple organic pollutants exhibiting endocrine-disrupting activity, namely atrazine, benzo[a]pyrene, 2,4-dichlorophenoxyacetic acid (2,4-D) and 4-nonylphenol, is reported. The biosensor utilizes a multichannel SPR sensor based on wavelength modulation of SPR and wavelength division multiplexing (WDM) of sensing channels, antibodies as biorecognition element and a competitive immunoassay detection format. An analysis time of 45 min (including 30-min incubation of the sample with antibodies) and limits of detection as low as 0.05, 0.07, 0.16 and 0.26 ng mL(-1) are demonstrated for benzo[a] pyrene, atrazine, 2,4-D and 4-nonylphenol, respectively. The biosensor is also shown to be regenerable and suitable for repeated use.
引用
收藏
页码:1841 / 1847
页数:7
相关论文
共 19 条
  • [1] [Anonymous], 2002, 17993 ISO
  • [2] Multichannel surface plasmon resonance biosensor with wavelength division multiplexing
    Dostálek, J
    Vaisocherová, H
    Homola, J
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) : 758 - 764
  • [3] MONOCLONAL ELISA FOR 2,4-DICHLOROPHENOXYACETIC ACID - CHARACTERIZATION OF ANTIBODIES AND ASSAY OPTIMIZATION
    FRANEK, M
    KOLAR, V
    GRANATOVA, M
    NEVORANKOVA, Z
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (06) : 1369 - 1374
  • [4] Development of a highly sensitive enzyme-linked immunosorbent assay for atrazine - Performance evaluation by flow injection immunoassay
    Gascon, J
    Oubina, A
    Ballesteros, B
    Barcelo, D
    Camps, F
    Marco, MP
    GonzalezMartinez, MA
    Morais, S
    Puchades, R
    Maquieira, A
    [J]. ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 149 - 162
  • [5] Highly sensitive detection of polycyclic aromatic hydrocarbons (PAHs) and association constants of the interaction between PAHs and antibodies using surface plasmon resonance immunosensor
    Gobi, KV
    Sasaki, M
    Shoyama, Y
    Miura, N
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (1-2) : 137 - 143
  • [6] Atrazine analysis using an amperometric immunosensor based on single-chain antibody fragments and regeneration-free multi-calibrant measurement
    Grennan, K
    Strachan, G
    Porter, AJ
    Killard, AJ
    Smyth, MR
    [J]. ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) : 287 - 298
  • [7] Investigation of highly sensitive piezoelectric immunosensors for 2,4-dichlorophenoxyacetic acid
    Halámek, J
    Hepel, M
    Skládal, P
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (4-5) : 253 - 260
  • [8] HERMANSON GT, 1996, BIOCONJUGATE TECHNIQ
  • [9] A DISPOSABLE AMPEROMETRIC IMMUNOSENSOR FOR 2,4-DICHLOROPHENOXYACETIC ACID
    KALAB, T
    SKLADAL, P
    [J]. ANALYTICA CHIMICA ACTA, 1995, 304 (03) : 361 - 368
  • [10] Multi-analyte SPR immunoassays for environmental biosensing of pesticides
    Mauriz, E.
    Calle, A.
    Manclus, J. J.
    Montoya, A.
    Lechuga, L. M.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (04) : 1449 - 1458