Relationship between Mid-Upper Arm Circumference and Body Mass Index in Inpatients

被引:63
作者
Benitez Brito, Nestor [1 ]
Suarez Llanos, Jose Pablo [1 ]
Fuentes Ferrer, Manuel [2 ]
Oliva Garcia, Jose Gregorio [1 ]
Delgado Brito, Irina [1 ]
Pereyra-Garcia Castro, Francisca [1 ]
Caracena Castellanos, Nieves [1 ]
Acevedo Rodriguez, Candelaria Xiomara [1 ]
Palacio Abizanda, Enrique [1 ]
机构
[1] Hosp Univ Nuestra Senora Candelaria, Endocrinol & Nutr Dept, Ctra Rosario 145, Santa Cruz De Tenerife 38010, Spain
[2] Hosp Clin San Carlos, Preventit Med Dept, Calle Prof Martin Lagos S-N, Madrid 28040, Spain
来源
PLOS ONE | 2016年 / 11卷 / 08期
关键词
CALF CIRCUMFERENCE; WEIGHT-LOSS; MALNUTRITION; UNDERNUTRITION; MORTALITY; IMPACT; RISK; MNA;
D O I
10.1371/journal.pone.0160480
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction Nutritional screening is a fundamental aspect of the initial evaluation of the hospitalised patient. Body Mass Index (BMI) in association with other parameters is a good marker of malnutrition (<18.5 kg/m(2)), but it presents the handicap that the great majority of patients cannot be weighed and measured. For this reason it is necessary to find other indicators that can be measured in these patients. Objectives 1) Analyse the relationship between BMI and Mid-Upper Arm Circumference (MUAC); 2) establish a cut-off point of MUAC equivalent to BMI <18.5 kg/m(2). Materials and Methods The anthropometric data of patients hospitalised over the period 2004-2013 were retrospectively revised. The following variables were collected: weight, height, BMI, MUAC, sex and age. Results 1373 patients were evaluated, who presented a mean weight of: 65.04 +/- 15.51 kg; height: 1.66 +/- 0.09 m; BMI: 23.48 +/- 5.03 kg/m(2); MUAC: 26.95 +/- 4.50 cm; age: 56.24 +/- 16.77. MUAC correlates suitably to BMI by means of the following equation (simple linear regression): BMI = -0.042 + 0.873 x MUAC (cm) (R-2 = 0.609), with a Pearson r value of 0.78 (p<0.001). The area under the curve of MUAC for the diagnosis of malnutrition was 0.92 (95% CI: 0.90-0.94; p<0.001). The MUAC value <= 22.5 cm presented a sensitivity of 67.7%, specificity of 94.5%, and a correct classification of 90%. No significant statistical differences were found in the cut-off point of MUAC for the diagnosis of malnutrition based on sex (p = 0.115) and age (p = 0.694). Conclusions 1) MUAC correlates positively and significantly with BMI. 2) MUAC <= 22.5 cm correlates properly with a BMI of <18.5 kg/m(2), independent of the age or sex of the patient, although there are other alternatives. MUAC constitutes a useful tool as a marker of malnutrition, fundamentally in patients for whom weight and height cannot be determined.
引用
收藏
页数:10
相关论文
共 26 条
  • [1] Alvarez J, 2008, NUTR HOSP, V23, P536
  • [2] Bickford G R, 1999, Clin Lab Manage Rev, V13, P357
  • [3] Diagnostic criteria for malnutrition - An ESPEN Consensus Statement
    Cederholm, T.
    Bosaeus, I.
    Barazzoni, R.
    Bauer, J.
    Van Gossum, A.
    Klek, S.
    Muscaritoli, M.
    Nyulasi, I.
    Ockenga, J.
    Schneider, S. M.
    de van der Schueren, M. A. E.
    Singer, P.
    [J]. CLINICAL NUTRITION, 2015, 34 (03) : 335 - 340
  • [4] Augusto CHC, 2011, NUTR CLIN DIET HOSP, V31, P22
  • [5] Chakraborty R, 2011, RURAL REMOTE HEALTH, V11
  • [6] The impact of malnutrition on morbidity, mortality, length of hospital stay and costs evaluated through a multivariate model analysis
    Correia, MITD
    Waitzberg, DL
    [J]. CLINICAL NUTRITION, 2003, 22 (03) : 235 - 239
  • [7] Malnutrition in hospitalized patients:: prevalence and economic impact
    de la Cruz, AP
    Támer, GL
    Espinosa, RO
    Pastor, CM
    de Hoyos, EA
    López, MDR
    [J]. MEDICINA CLINICA, 2004, 123 (06): : 201 - 206
  • [8] Anamnestic weight loss-do patients remember correctly?
    Eriksen, J.
    Sneftrup, S. B.
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 (06) : 607 - 609
  • [9] Arm measurements as determinants of further survival in centenarians
    Gueresi, Paola
    Miglio, Rossella
    Cevenini, Elisa
    Russo, Emanuela Gualdi
    [J]. EXPERIMENTAL GERONTOLOGY, 2014, 58 : 230 - 234
  • [10] Guerrero-Segundo M, 2012, REV SANID MILIT MEX, V66, P17