Preparation and in situ characterization of surfaces using soft landing in a Fourier transform ion cyclotron resonance mass spectrometer

被引:51
作者
Alvarez, J
Cooks, RG
Barlow, SE
Gaspar, DJ
Futrell, JH
Laskin, J [1 ]
机构
[1] Fundamental Sci Directorate, Richland, WA 99352 USA
[2] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
[3] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
D O I
10.1021/ac0481349
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mass-selected peptide ions produced by electrospray ionization were deposited onto fluorinated self-assembled monolayer surfaces (FSAM) surfaces by soft landing using a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) specially designed for studying interactions of large ions with surfaces. Analysis of the modified surface was performed in situ by combining 2-keV Cs+ secondary ion mass spectrometry with FT-ICR detection of the sputtered ions (FT-ICR-SIMS). Regardless of the initial charge state of the precursor ion, the SIMS mass spectra included singly protonated peptide ion, peptide fragment ions, and peaks characteristic of the surface in all cases. In some experiments, multiply protonated peptide ions and [M + Au](+) ions were also observed upon SIMS analysis of modified surfaces. For comparison with the in situ analysis of the modified surfaces, ex situ analysis of some of the modified surfaces was performed by 25-keV Ga+ time-of-flight-secondary ion mass spectrometry (TOF-SIMS). The ex situ analysis demonstrated that a significant number of soft-landed peptide ions remain charged on the surface even when exposed to air for several hours after deposition. Charge retention of soft-landed ions dramatically increases the ion yields obtained during SIMS analysis and enables very sensitive detection of deposited material at less than 1% of monolayer coverage. Accumulation of charged species on the surface undergoes saturation due to coulomb repulsion between charges at close to 30% coverage. We estimated that close to 1 ng of peptide could be deposited on the spot area of 4 mm(2) of the FSAM surface without reaching saturation.
引用
收藏
页码:3452 / 3460
页数:9
相关论文
共 37 条
[1]  
ALVAREZ JLM, UNPUB
[2]   CESIUM ION DESORPTION IONIZATION WITH FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
AMSTER, IJ ;
LOO, JA ;
FURLONG, JJP ;
MCLAFFERTY, FW .
ANALYTICAL CHEMISTRY, 1987, 59 (02) :313-317
[3]   SECONDARY ION MASS-SPECTRA OF SOME SIMPLE ORGANIC-MOLECULES [J].
BARBER, M ;
VICKERMAN, JC ;
WOLSTENHOLME, J .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1980, 76 :549-559
[4]   Linearizing an ion cyclotron resonance cell [J].
Barlow, SE ;
Tinkle, MD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (12) :4185-4200
[5]   NOMENCLATURE FOR PEPTIDE FRAGMENT IONS (POSITIVE-IONS) [J].
BIEMANN, K .
METHODS IN ENZYMOLOGY, 1990, 193 :886-887
[6]  
Bunshah F.R., 1994, HDB DEPOSITION TECHN, V2
[7]   DESORPTION IONIZATION OF CESIUM IODIDE BY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CASTRO, ME ;
RUSSELL, DH .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2290-2293
[8]   CESIUM DESORPTION IONIZATION STUDIES OF BETA-CYCLODEXTRIN BY FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CASTRO, ME ;
MALLIS, LM ;
RUSSELL, DH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1985, 107 (20) :5652-5657
[9]   CESIUM ION DESORPTION IONIZATION WITH FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CASTRO, ME ;
RUSSELL, DH .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :578-581
[10]   MOLECULAR ORDER AT THE SURFACE OF AN ORGANIC MONOLAYER STUDIED BY LOW-ENERGY HELIUM DIFFRACTION [J].
CHIDSEY, CED ;
LIU, GY ;
ROWNTREE, P ;
SCOLES, G .
JOURNAL OF CHEMICAL PHYSICS, 1989, 91 (07) :4421-4423