Cost-effectiveness of drug-eluting coronary stents in Quebec, Canada

被引:21
作者
Brophy, JM
Erickson, LJ
机构
[1] McGill Univ, Royal Victoria Hosp, Hlth Ctr,Dept Med, Div Cardiol, Montreal, PQ H3A 1A1, Canada
[2] McGill Univ, Royal Victoria Hosp, Hlth Ctr,Dept Med, Div Clin Epidemiol, Montreal, PQ H3A 1A1, Canada
[3] McGill Univ, Ctr Hlth, AETMIS, Technol Assessment Unit, Montreal, PQ, Canada
关键词
cost-effectiveness; cardiology; coronary stents;
D O I
10.1017/S0266462305050439
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objectives: The aim of this investigation was to assess the incremental cost-effectiveness of replacing bare metal coronary stents (BMS) with drug-eluting stents (DES) in the Province of Quebec, Canada. Methods: The strategy used was a cost-effectiveness analysis from the perspective of the health-care provider, in the province of Quebec, Canada (population 7.5 million). The main outcome measure was the cost per avoided revascularization intervention. Results: Based on the annual Quebec rate of 14,000 angioplasties with an average of 1.7 stents per procedure and a purchase cost of $2,600 Canadian dollar (CDN) for DES, 100 percent substitution of BMS with DES would require an additional $45.1 million CDN of funding. After the benefits of reduced repeat revascularization interventions are included, the incremental cost would be $35.2 million CDN. The cost per avoided revascularization intervention (18 percent coronary artery bypass graft, 82 percent percutaneous coronary intervention [PCI]) would be $23,067 CDN. If DES were offered selectively to higher risk populations, for example, a 20 percent subgroup with a relative restenosis risk of 2.5 times the current bare metal rate, the incremental cost of the program would be $4.9 million CDN at a cost of $7,800 per avoided revascularization procedure. Break-even costs for the program would occur at DES purchase cost of $1,161 for 100 percent DES use and $1,627 for selective 20 percent DES use for high-risk patients for restenosis (RR = 2.5). Univariate and Monte Carlo sensitivity analyses indicate that the parameters most affecting the analysis are the capacity to select patients at high risk of restenosis, the average number of stents used per PCI, baseline restenosis rates for BMS, the effectiveness ratio of restenosis prevention for DES versus BMS, the cost of DES, and the revascularization rate after initial PCI. Sensitivity analyses suggest little additional health benefits but escalating cost-effectiveness ratios once a DES penetration of 40 percent has been attained. Conclusions: Under current conditions in Quebec, Canada, selective use of DES in high-risk patients is the most acceptable strategy in terms of cost-effectiveness. Results of such an analysis would be expected to be similar in other countries with key model parameters similar to those used in this model. This model provides an example of how to evaluate the cost-effectiveness of selective use of a new technology in high-risk patients.
引用
收藏
页码:326 / 333
页数:8
相关论文
共 22 条
[1]   A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents [J].
Babapulle, MN ;
Joseph, L ;
Bélisle, P ;
Brophy, JM ;
Eisenberg, MJ .
LANCET, 2004, 364 (9434) :583-591
[2]  
BOLOGNESE L, INDICAZIONI ALLUSO S
[3]   Evidence for use of coronary Stents - A hierarchical Bayesian meta-analysis [J].
Brophy, JM ;
Belisle, P ;
Joseph, L .
ANNALS OF INTERNAL MEDICINE, 2003, 138 (10) :777-786
[4]   Percutaneous transluminal coronary angioplasty versus medical treatment for non-acute coronary heart disease: meta-analysis of randomised controlled trials [J].
Bucher, HC ;
Hengstler, P ;
Schindler, C ;
Guyatt, GH .
BMJ-BRITISH MEDICAL JOURNAL, 2000, 321 (7253) :73-77
[5]   Cost-effectiveness of sirolimus-eluting stents for treatment of complex coronary stenoses - Results from the sirolimus-eluting balloon expandable stent in the treatment of patients with de novo native coronary artery lesions (SIRIUS) trial [J].
Cohen, DJ ;
Bakhai, A ;
Shi, CX ;
Githiora, L ;
Lavelle, T ;
Berezin, RH ;
Leon, MB ;
Moses, JW ;
Carrozza, JP ;
Zidar, JP ;
Kuntz, RE .
CIRCULATION, 2004, 110 (05) :508-514
[6]   Trends in clinical and economic outcomes of coronary angioplasty from 1992 to 1995: A population-based analysis [J].
Cohen, EA ;
Young, W ;
Slaughter, PM ;
Oh, P ;
Naylor, CD .
AMERICAN HEART JOURNAL, 1999, 137 (06) :1012-1018
[7]  
*CONS EV TECHN SAN, 1996, REV TECHN US TREATM
[8]   Beyond restenosis - Five-year clinical outcomes from second-generation coronary stent trials [J].
Cutlip, DE ;
Chhabra, AG ;
Baim, DS ;
Chauhan, MS ;
Marulkar, S ;
Massaro, J ;
Bakhai, A ;
Cohen, DJ ;
Kuntz, RE ;
Ho, KKL .
CIRCULATION, 2004, 110 (10) :1226-1230
[9]   Pathology of acute and chronic coronary stenting in humans [J].
Farb, A ;
Sangiorgi, G ;
Carter, AJ ;
Walley, VM ;
Edwards, WD ;
Schwartz, RS ;
Virmani, R .
CIRCULATION, 1999, 99 (01) :44-52
[10]  
GREENBERG D, 2003, AM J DRUG DELIVERY, V1, P255