Quality checks and first calibration of the KLOE electromagnetic calorimeter

被引:4
作者
Antonelli, M
Barbiellini, G
Bertolucci, S
Bini, C [1 ]
Bloise, C
Cabibbo, G
Caloi, R
Campana, P
Cervelli, F
De Zorzi, G
Di Cosimo, G
Di Domenico, A
Di Falco, S
Erriquez, O
Farilla, A
Ferrari, A
Franzini, P
Galli, A
Gauzzi, P
Giovannella, S
Graziani, E
Han, HQ
Han, SW
Incagli, M
Kim, W
Lanfranchi, G
Lee-Franzini, J
Lomtadze, T
Minashvili, I
Miscetti, S
Murtas, F
Passeri, A
Scuri, F
Spiriti, E
Tortora, L
Venanzoni, G
Xie, YG
Zhang, JQ
机构
[1] Univ Rome, Dipartimento Fis, Roma 1, Italy
[2] Ist Nazl Fis Nucl, Roma 1, Italy
[3] Univ Bari, Dipartmento Fis, I-70121 Bari, Italy
[4] Ist Nazl Fis Nucl, I-70126 Bari, Italy
[5] Acad Sinica, Inst High Energy Phys, Beijing, Peoples R China
[6] Ist Nazl Fis Nucl, Lab Nazl Frascati, I-00044 Frascati, Italy
[7] Columbia Univ, Dept Phys, New York, NY 10027 USA
[8] Univ Pisa, Dipartimento Fis, I-56100 Pisa, Italy
[9] Ist Nazl Fis Nucl, Pisa, Italy
[10] Ist Super Sanita, INFN, I-00161 Rome, Italy
[11] SUNY Stony Brook, Dept Phys, Stony Brook, NY 11794 USA
[12] Ist Nazl Fis Nucl, Trieste, Italy
[13] Univ Trieste, Dipartmento Fis, I-34127 Trieste, Italy
关键词
D O I
10.1016/S0168-9002(97)01317-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The construction of the KLOE lead-scintillating fibres electromagnetic calorimeter has been completed. The final results of the extensive quality checks of all the calorimeter modules are presented here. The measurements have been done in the Frascati Laboratories at a cosmic ray test facility using minimum ionizing particles. The results show that all the calorimeter modules are well fulfilling the design specifications concerning time and energy resolutions. Furthermore, by using the same cosmic ray facility, all the calorimeter elements have been also pre-calibrated. (C) 1998 Elsevier Science B.V, All rights reserved.
引用
收藏
页码:558 / 560
页数:3
相关论文
共 6 条
[1]  
ANELLI M, 1995, 136 KLOE
[2]  
ANELLI M, 1997, 9787 KLOE
[3]   Performance of fine mesh photomultiplier tubes in magnetic fields up to 0.3 T [J].
Antonelli, A ;
Antonelli, M ;
Barbiellini, G ;
Barone, M ;
Bertolucci, S ;
Bini, C ;
Bloise, C ;
Bossi, F ;
Caloi, R ;
Campana, P ;
Cervelli, F ;
Cordelli, M ;
DeZorzi, G ;
DiCosimo, G ;
DiDomenico, A ;
Erriquez, O ;
Farilla, A ;
Ferrari, A ;
Franzini, P ;
Garufi, F ;
Gauzzi, P ;
Giovannella, S ;
Incagli, M ;
Keeble, L ;
Kim, W ;
Lanfranchi, G ;
LeeFranzini, J ;
Martinis, A ;
Miscetti, S ;
Murtas, F ;
Passeri, A ;
Scuri, F ;
Spiriti, E ;
Tortora, L ;
Venanzoni, G ;
Wolfle, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 368 (03) :628-634
[4]   CONSTRUCTION AND PERFORMANCE OF THE LEAD-SCINTILLATING FIBER CALORIMETER PROTOTYPES FOR THE KLOE DETECTOR [J].
ANTONELLI, A ;
ANTONELLI, M ;
BARBIELLINI, G ;
BARONE, M ;
BERTOLUCCI, S ;
BIANCO, S ;
BINI, C ;
BLOISE, C ;
BOLOGNESI, V ;
BOSSI, F ;
CAMPANA, P ;
CERVELLI, F ;
CALOI, R ;
CORDELLI, M ;
DEZORZI, G ;
DICOSIMO, G ;
DIDOMENICO, A ;
ERRIQUEZ, O ;
FABBRI, FL ;
FARILLA, A ;
FERRARI, A ;
FRANZINI, P ;
GARUFI, F ;
GAUZZI, P ;
GERO, E ;
GIOVANNELLA, S ;
HAYDAR, R ;
INCAGLI, M ;
KEEBLE, L ;
KIM, W ;
LANFRANCHI, G ;
LEEFRANZINI, J ;
MARTINI, A ;
MARTINIS, A ;
MISCETTI, S ;
MURTAS, F ;
PARRI, A ;
PASSERI, A ;
SARWAR, S ;
SCURI, F ;
SPIRITI, E ;
TORTORA, L ;
WANG, XL ;
WOLFLE, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 354 (2-3) :352-363
[5]  
ANTONELLI A, 1995, 152 KLOE
[6]  
GAUZZI P, 1996, P 6 INT C CAL HIGH E, P359