Neutron irradiation of RPCs for the CMS experiment

被引:4
作者
Abbrescia, M
Colaleo, A
Iaselli, G
Loddo, F
Maggi, M
Marangelli, B
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Romano, F
Altieri, S
Belli, G
Bruno, G
Guida, R
Ratti, SP
Riccardi, C
Torre, P
Vitulo, P
机构
[1] Univ Bari, Dipartimento Interateneo Fis, I-70126 Bari, Italy
[2] Univ Bari, Sez INFN, I-70126 Bari, Italy
[3] Dipartimento Fis Teorica & Nucl, I-27100 Pavia, Italy
[4] Sez INFN, I-27100 Pavia, Italy
关键词
resistive plate chambers; CMS; neutron irradiation;
D O I
10.1016/S0168-9002(03)01290-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
All the CMS muon stations will be equipped with Resistive Plate Chambers (RPCs). They will be exposed to high neutron background environment during the LHC running. In order to verify the safe operation of these detectors, an irradiation test has been carried out with two RPCs at high neutron flux (about 10(8) n cm(-2) s(-1)), integrating values of dose and fluence equivalent to 10 LHC-years. Before and after the irradiation, the performance of the detectors was studied with cosmic muons, showing no relevant aging effects. Moreover, no indication of damage or chemical changes were observed on the electrode surfaces. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:120 / 123
页数:4
相关论文
共 8 条
[1]   Resistive plate chambers performances at low pressure [J].
Abbrescia, M ;
Bisceglie, E ;
Iaselli, G ;
Natali, S ;
Pugliese, G ;
Romano, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 394 (03) :341-348
[2]   Long-term performance of double gap resistive plate chambers under gamma irradiation [J].
Abbrescia, M ;
Colaleo, A ;
Guarrasi, L ;
Iaselli, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pugliese, G ;
Ranieri, A ;
Romano, F ;
Altieri, S ;
Belli, G ;
Bruno, G ;
Gianini, G ;
Ratti, SP ;
Riccardi, C ;
Torre, P ;
Viola, L ;
Vitulo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) :293-298
[3]   New developments on front-end electronics for the CMS Resistive Plate Chambers [J].
Abbrescia, M ;
Colaleo, A ;
Iaselli, G ;
Loddo, F ;
Maggi, M ;
Marangelli, B ;
Natali, S ;
Nuzzo, S ;
Pugliese, G ;
Ranieri, A ;
Romano, F ;
Altieri, S ;
Barnaba, O ;
Belli, G ;
Bruno, G ;
Musitelli, G ;
Nardo, R ;
Ratti, SP ;
Riccardi, C ;
Torre, P ;
Vitulo, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 456 (1-2) :143-149
[4]  
ABBRESCIA M, 2001, IN PRESS NUCL INSTR
[5]  
BRUNO G, 2001, P 6 INT WORKSH RES P
[6]  
*CMS, 9732 CMS CERNLHCC
[7]  
GUIDA R, 2001, P 6 INT WORKSH RES P
[8]   Drying and oxidative degradation of linseed oil [J].
Lazzari, M ;
Chiantore, O .
POLYMER DEGRADATION AND STABILITY, 1999, 65 (02) :303-313