Interface for direct and continuous sample-matrix deposition onto a MALDI probe for polymer analysis by thermal field flow fractionation and off-line MALDI-MS

被引:14
作者
Basile, F [1 ]
Kassalainen, GE [1 ]
Williams, SKR [1 ]
机构
[1] Colorado Sch Mines, Dept Chem, Golden, CO 80401 USA
关键词
D O I
10.1021/ac048391d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple interface based on an oscillating capillary nebulizer (OCN) is described for direct deposition of eluate from a thermal field-flow fractionation (ThFFF) system onto a matrix-assisted laser desorption/ionization (MAL-DI) probe. In this study, the polymer-containing eluent from the ThFFF system was mixed on-line with MALDI matrix solution and deposited directly onto a moving MALDI probe. The result was a continuous sample track representative of the fractionation process. Subsequent off-line MALDI-mass spectrometry analysis was performed in automated and manual modes. Polystyrene samples of broad polydispersity were used to characterize the overall system performance. The OCN interface is easy to build and operate without the use of heaters or high voltages and is compatible with any MALDI probe format.
引用
收藏
页码:3008 / 3012
页数:5
相关论文
共 40 条
[1]   Mass discrimination effects in an ion detector and other causes for shifts in polymer mass distributions measured by matrix-assisted laser desorption ionization time-of-flight mass spectrometry [J].
Axelsson, J ;
Scrivener, E ;
Haddleton, DM ;
Derrick, PJ .
MACROMOLECULES, 1996, 29 (27) :8875-8882
[2]  
Axelsson J, 1997, RAPID COMMUN MASS SP, V11, P209, DOI 10.1002/(SICI)1097-0231(19970131)11:2<209::AID-RCM734>3.0.CO
[3]  
2-E
[4]  
BASILE F, 2001, 49 M AM SOC MASS SPE
[5]   The limitations of MALDI-TOF mass spectrometry in the analysis of wide polydisperse polymers [J].
Byrd, HCM ;
McEwen, CN .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4568-4576
[6]   On-line atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry [J].
Daniel, JM ;
Ehala, S ;
Friess, SD ;
Zenobi, R .
ANALYST, 2004, 129 (07) :574-578
[7]  
DWYER JL, 1999, ACS SYM SER, V731, pCH7
[8]   Matrix-assisted laser desorption/ionization mass spectrometry of synthetic polymers. 4. Coupling of size exclusion chromatography and MALDI-TOF using a spray-deposition interface [J].
Esser, E ;
Keil, C ;
Braun, D ;
Montag, P ;
Pasch, H .
POLYMER, 2000, 41 (11) :4039-4046
[9]   A simple and inexpensive approach to interfacing high-performance liquid chromatography and matrix-assisted laser desorption/ionization-time of flight-mass spectrometry [J].
Fung, KYC ;
Askovic, S ;
Basile, F ;
Duncan, MW .
PROTEOMICS, 2004, 4 (10) :3121-3127
[10]   Interfaces for coupled liquid-phase separation/mass spectrometry techniques.: An update on recent developments [J].
Gelpí, E .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (03) :241-253