Mechanical properties of coronary stents determined by using finite element analysis

被引:164
作者
Etave, F
Finet, G
Boivin, M
Boyer, JC
Rioufol, G
Thollet, G
机构
[1] INSA, Lab Mech, Lyon, France
[2] Univ Lyon 1, Hospices Civils Lyon, Dept Hemodynam, F-69365 Lyon, France
[3] INSERM, UMR 5515, CNRS, CREATIS Res Unit, Lyon, France
[4] INSA, Lab Scanning Electron Microscopy, GEMPPM, Lyon, France
关键词
stent; angioplasty; finite-element analysis; mechanics; simulation;
D O I
10.1016/S0021-9290(01)00026-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The mechanical function of a stent deployed in a damaged artery is to provide a metallic tubular mesh structure. The purpose of this study was to determine the exact mechanical characteristics of stents. In order to achieve this, we have used finite-element analysis to model two different type of stents: tubular stents (TS) and coil stents (CS). The two stents chosen for this modeling present the most extreme mechanical characteristics of the respective types. Seven mechanical properties were studied by mathematical modeling with determination of: (1) stent deployment pressure, (2) the intrinsic elastic recoil of the material used, (3) the resistance of the stent to external compressive forces, (4) the stent foreshortening, (5) the stent coverage area, (6) the stent flexibility, and (7) the stress maps. The pressure required for deployment of CS was significantly lower than that required for TS, over 2.8 times greater pressure was required for the tubular model. The elastic recoil of TS is higher than CS (5.4% and 2.6%, respectively). TS could be deformed by 10% at compressive pressures of between 0.7 and 1.3 atm whereas CS was only deformed at 0.2 and 0.7 arm. The degree of shortening observed increases with deployment diameter for TS. CS lengthen during deployment. The metal coverage area is two times greater for TS than for CS. The ratio between the stiffness of TS and that of CS varies from 2060 to 2858 depending on the direction in which the force is applied. TS are very rigid and CS are significantly more flexible. Stress mapping shows stress to be localized at link nodes. This series of finite-element analyses illustrates and quantifies the main mechanical characteristics of two different commonly used stents. In interventional cardiology, we need to understand their mechanisms of implantation and action. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1065 / 1075
页数:11
相关论文
共 26 条
[1]  
Balcon R, 1997, EUR HEART J, V18, P1536
[2]  
Barragan P, 2000, CATHETER CARDIO INTE, V50, P112, DOI 10.1002/(SICI)1522-726X(200005)50:1<112::AID-CCD25>3.0.CO
[3]  
2-X
[4]  
CARROZZA JP, 1996, CIRCULATION, pI88
[5]  
DEGALLAIX S, 1992, GIS P
[6]  
DEJAEGERE P, 1994, CATHETER CARDIO DIAG, V32, P147
[7]   Mechanical behaviour modelling of balloon-expandable stents [J].
Dumoulin, C ;
Cochelin, B .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1461-1470
[8]  
FISHMAN HC, 1991, J AM COLLEGE CADIOLO, V18, P14
[9]   STRENGTH, ELASTICITY, AND PLASTICITY OF EXPANDABLE METAL STENTS - IN-VITRO STUDIES WITH 3 TYPES OF STRESS [J].
FLUECKIGER, F ;
STERNTHAL, H ;
KLEIN, GE ;
ASCHAUER, M ;
SZOLAR, D ;
KLEINHAPPL, G .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) :745-750
[10]  
GLOGAR D, 1997, J AM COLLEGE CARDIOL