MR renography with low-dose gadopentetate dimeglumine: Feasibility

被引:44
作者
Lee, VS [1 ]
Rusinek, H [1 ]
Johnson, G [1 ]
Rofsky, NM [1 ]
Krinsky, GA [1 ]
Weinreb, JC [1 ]
机构
[1] NYU, Dept Radiol MRI, New York, NY 10016 USA
关键词
kidney; function; magnetic resonance (MR); vascular studies; renal arteries; stenosis or obstruction;
D O I
10.1148/radiol.2212010142
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To develop a low-dose magnetic resonance (MR) renographic method performed with and without an angiotensin converting enzyme (ACE) inhibitor and in conjunction with gadolinium-enhanced MR angiography in patients with suspected renovascular disease. MATERIALS AND METHODS: Thirty-two patients underwent MR renography (turbo fast low-angle shot sequence: repetition time, 5 msec; echo time, 2.3 msec; flip angle, 15 degrees; one coronal image acquired every 2 seconds for 4 minutes) following intravenous injection of 2 mL of gadopentetate dimeglumine, which was repeated following intravenous injection of an ACE inhibitor. Contrast material-enhanced MR angiography was also performed. On the basis of renographic findings, renal cortex and renal medulla enhancement curves and normalized enhancement ratios were analyzed. RESULTS: The cortex and medulla showed an early transient period of enhancement within 20 seconds (vascular phase). During 1-2 minutes, a second, gradual increase in medullary enhancement, reflecting transit of filtered contrast material, was observed that was significantly greater in patients with a serum creatinine level less than 2 mg/dL (177 mu mol/L) than in those with a level of 2 mg/dL or greater (P <.01). After injection of the ACE inhibitor, patients with elevated creatinine levels showed low renal medullary enhancement regardless of the presence of renal artery stenosis (RAS). However, in patients with creatinine less than 2 mg/dL, medullary enhancement ratios after injection of the ACE inhibitor were consistently lower in patients with RAS of 50% or greater than in those without stenosis (P =.02 to .08). CONCLUSION: Low-dose MR renography can be performed in the clinical setting before and after injection of an ACE inhibitor, and its potential use for evaluating decreased renal function as a consequence of RAS is promising.
引用
收藏
页码:371 / 379
页数:9
相关论文
共 31 条
[1]   USE OF GD-DTPA AND FAST GRADIENT-ECHO AND SPIN-ECHO MR IMAGING TO DEMONSTRATE RENAL-FUNCTION IN THE RABBIT [J].
CARVLIN, MJ ;
ARGER, PH ;
KUNDEL, HL ;
AXEL, L ;
DOUGHERTY, L ;
KASSAB, EA ;
MOORE, B .
RADIOLOGY, 1989, 170 (03) :705-711
[2]   PATIENTS AT HIGH-RISK FOR RENAL-ARTERY STENOSIS - A SIMPLE METHOD OF RENAL SCINTIGRAPHIC ANALYSIS WITH TC-99M DTPA AND CAPTOPRIL [J].
CHEN, CC ;
HOFFER, PB ;
VAHJEN, G ;
GOTTSCHALK, A ;
KOSTER, K ;
ZUBAL, IG ;
SETARO, JF ;
ROER, DA ;
BLACK, HR .
RADIOLOGY, 1990, 176 (02) :365-370
[3]   HYDRATED CLEARANCE OF GADOLINIUM-DTPA AS A MEASUREMENT OF GLOMERULAR-FILTRATION RATE [J].
CHOYKE, PL ;
AUSTIN, HA ;
FRANK, JA ;
GIRTON, ME ;
DIGGS, RL ;
DWYER, AJ ;
MILLER, L ;
NUSSENBLATT, R ;
MCFARLAND, H ;
SIMON, T .
KIDNEY INTERNATIONAL, 1992, 41 (06) :1595-1598
[4]  
DANIELSON M, 1981, ACTA MED SCAND, V209, P451
[5]   NONINVASIVE MEASUREMENT OF RENAL HEMODYNAMIC FUNCTIONS USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING [J].
DUMOULIN, CL ;
BUONOCORE, MH ;
OPSAHL, LR ;
KATZBERG, RW ;
DARROW, RD ;
MORRIS, TW ;
BATEY, C .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :370-378
[6]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[7]   ANGIOGRAPHY OF THE RENAL AREAS INCLUDING A COMPARATIVE STUDY OF RENAL ARTERIAL STENOSES IN PATIENTS WITH AND WITHOUT HYPERTENSION [J].
EYLER, WR ;
CLARK, MD ;
GARMAN, JE ;
RIAN, RL ;
MEININGER, DE .
RADIOLOGY, 1962, 78 (06) :879-892
[8]   GADOPENTETATE DIMEGLUMINE AS A MARKER OF RENAL-FUNCTION - MAGNETIC-RESONANCE-IMAGING TO GLOMERULAR-FILTRATION RATES [J].
FRANK, JA ;
CHOYKE, PL ;
AUSTIN, HA ;
GIRTON, ME ;
WEISS, G .
INVESTIGATIVE RADIOLOGY, 1991, 26 :S134-S136
[9]   Evaluation of glomerular function in individual kidneys using dynamic magnetic resonance imaging [J].
Fukuda, Y ;
Watanabe, H ;
Tomita, T ;
Katayama, H ;
Miyano, T ;
Yabuta, K .
PEDIATRIC RADIOLOGY, 1996, 26 (05) :324-328