A Randomized, Controlled, Multicenter Trial to Evaluate the Safety and Efficacy of Zotarolimus-Versus Paclitaxel-Eluting Stents in De Novo Occlusive Lesions in Coronary Arteries The ZoMaxx I Trial

被引:26
作者
Chevalier, Bernard [2 ]
Di Mario, Carlo [3 ]
Neumann, Franz-Josef [4 ]
Ribichini, Flavio [5 ]
Urban, Philip [6 ]
Popma, Jeffrey J. [7 ]
Fitzgerald, Peter J. [8 ]
Cutlip, Donald E. [9 ]
Williams, David O. [10 ]
Ormiston, John [11 ]
Grube, Eberhard [12 ]
Whitbourn, Robert [13 ]
Schwartz, Lewis B. [1 ]
机构
[1] Abbott Labs, Abbott Pk, IL 60064 USA
[2] Ctr Cardiol Nord, St Denis, France
[3] Royal Brompton Hosp, London SW3 6LY, England
[4] Herz Zentrum Bad Krozingen, Bad Krozingen, Germany
[5] Univ Piemonte Orientale, Novara, Italy
[6] La Tour Hosp, Geneva, Switzerland
[7] Brigham & Womens Hosp, Boston, MA 02115 USA
[8] Stanford Univ, Med Ctr, Palo Alto, CA 94304 USA
[9] Harvard Clin Res Inst, Boston, MA USA
[10] Rhode Isl Hosp, Providence, RI USA
[11] Auckland City Hosp, Auckland, New Zealand
[12] Heart Ctr Siegburg, Siegburg, Germany
[13] St Vincents Hosp, Melbourne, Vic, Australia
关键词
drug-eluting stent; stent; zotarolimus; restenosis; coronary artery disease;
D O I
10.1016/j.jcin.2008.08.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives A novel zotarolimus-eluting coronary stent system (ZoMaxx, Abbott Laboratories, Abbott Park, Illinois) was compared with a paclitaxel-eluting coronary stent (Taxus Express2) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. The primary end point was defined as noninferiority of in-segment late lumen loss after 9 months. Background The ZoMaxx stent system elutes 10 mu g/mm zotarolimus using a phosphorylcholine polymer loaded onto a novel stainless steel stent platform containing a 0.0007-inch inner layer of tantalum. Methods Twenty-nine investigative sites in Europe, Australia, and New Zealand enrolled 401 patients, 396 of whom received a study stent. Results After 9 months, late lumen loss was significantly greater in the ZoMaxx group (in-stent 0.67 +/- 0.57 mm vs. 0.45 +/- 0.48 mm; p < 0.001; in-segment 0.43 +/- 0.60 mm vs. 0.25 +/- 0.45 mm; p = 0.003), resulting in significantly higher rates of >50% angiographic restenosis (in-stent 12.9% vs. 5.7%; p = 0.03; in-segment 16.5% vs. 6.9%; p = 0.007). The upper bound of the 95% confidence interval on the difference in in-segment late lumen loss between the 2 treatment groups (0.27 mm) exceeded the 0.25 mm value pre-specified for noninferiority. There were no significant differences between ZoMaxx and Taxus-treated groups with respect to target lesion revascularization (8.0% vs. 4.1%; p = 0.14), major adverse cardiac events (12.6% vs. 9.6%; p = 0.43), or stent thrombosis (0.5% in both groups). Conclusions After 9 months, the ZoMaxx stent showed less neointimal inhibition than the Taxus stent, as shown by higher in-stent late loss and restenosis by qualitative coronary angiography. (J Am Coll Cardiol Intv 2008;1:524-32) (C) 2008 by the American College of Cardiology Foundation
引用
收藏
页码:524 / 532
页数:9
相关论文
共 47 条
[1]   Clinical and angiographic results of percutaneous coronary revascularization using a trilayer stainless steel-tantalum-stainless steel phosphorylcholine-coated stent: The Trimaxx trial [J].
Abizaid, Alexandre ;
Popma, Jeffrey J. ;
Tanajura, Luis F. ;
Hattori, Kyoko ;
Solberg, Brad ;
Larracas, Cristina ;
Feres, Fausto ;
Costa, Jose de Ribamar, Jr. ;
Schwartz, Lewis B. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (07) :914-919
[2]   Percutaneous coronary revascularization using a trilayer metal phosphorylcholine-coated zotarolimus-eluting stent [J].
Abizaid, Alexandre ;
Lansky, Alexandra J. ;
Fitzgerald, Peter J. ;
Tanajura, Luis Fernando ;
Feres, Fausto ;
Staico, Rodolfo ;
Mattos, Luiz ;
Abizaid, Andrea ;
Chaves, Aurea ;
Centemero, Marinella ;
Sousa, Amanda G. M. R. ;
Sousa, J. Eduardo ;
Zaugg, Margo J. ;
Schwartz, Lewis B. .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (10) :1403-1408
[3]  
BENESH P, 2007, INVESTORS BUSIN 1102
[4]  
BOLAND JL, 2000, INT J CARDIOVASC INT, V3, P215
[5]   Zotarolimus (ABT-578) eluting stents [J].
Burke, Sandra E. ;
Kuntz, Richard E. ;
Schwartz, Lewis B. .
ADVANCED DRUG DELIVERY REVIEWS, 2006, 58 (03) :437-446
[6]   Biocompatible surfaces using methacryloylphosphorylcholine laurylmethacrylate copolymer [J].
Campbell, E.J. ;
O'Byrne, V. ;
Stratford, P.W. ;
Quirk, I. ;
Vick, T.A. ;
Wiles, M.C. ;
Yianni, Y.P. .
ASAIO Journal, 1994, 40 (03)
[7]   Zotarolimus, a novel Sirolimus analogue with potent anti-proliferative activity on coronary smooth muscle cells and reduced potential for systemic immunosuppression [J].
Chen, Yung-Wu ;
Smith, Morey L. ;
Sheets, Michael ;
Ballaron, Steve ;
Trevillyan, James M. ;
Burke, Sandra E. ;
Rosenberg, Teresa ;
Henry, Cindy ;
Wagner, Rolf ;
Bauch, Joy ;
Marsh, Kennan ;
Fey, Thomas A. ;
Hsieh, Gin ;
Gauvin, Donna ;
Mollison, Karl W. ;
Carter, George W. ;
Djuric, Stevan W. .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 2007, 49 (04) :228-235
[8]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[9]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[10]  
DuVall M, 2004, AM J CARDIOL, V94, p223E