Primary Sclerosing Cholangitis: Meta-Analysis of Diagnostic Performance of MR Cholangiopancreatography

被引:166
作者
Dave, Maneesh [3 ]
Elmunzer, B. Joseph [1 ]
Dwamena, Ben A. [2 ]
Higgins, Peter D. R. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Internal Med, Ann Arbor, MI 48109 USA
[2] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI 48109 USA
[3] Wayne State Univ, Dept Internal Med, Detroit, MI 48202 USA
关键词
MAGNETIC-RESONANCE CHOLANGIOPANCREATOGRAPHY; SYSTEMATIC REVIEWS; TEST ACCURACY; CHOLANGIOGRAPHY; ERCP; COMPLICATIONS; SPECIFICITY; SENSITIVITY;
D O I
10.1148/radiol.10091953
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To determine the diagnostic accuracy of magnetic resonance cholangiopancreatography (MRCP) for detection of primary sclerosing cholangitis (PSC) in patients with biochemical cholestasis. Materials and Methods: Two reviewers searched MEDLINE, EMBASE, and other electronic databases to identify prospective studies in which MRCP was evaluated and compared with endoscopic retrograde cholangiopancreatography (ERCP), clinical examination, and/ or histologic analysis for diagnosis of PSC in cholestasis and control cases. Main study inclusion criteria were (a) use of ERCP or percutaneous transhepatic cholangiography (PTC) as part of the reference standard for the diagnosis of PSC, (b) inclusion of patients with hepatobiliary disease other than PSC (ie, nonhealthy control subjects), (c) blinding of MRCP image readers to reference-standard results, (d) prospective study with ERCP or MRCP performed after subject recruitment into the study, and (e) inclusion of raw data (for true-positive, false-positive, true-negative, and false-negative results) that could be found or calculated from the original study data. Major exclusion criteria were duplicate article (on a primary study) that contained all or some of the original study data and inclusion of fewer than 10 patients with PSC. Methodologic quality was assessed by using the Quality Assessment of Diagnostic Accuracy Studies tool. Bivariate random-effects meta-analytic methods were used to estimate summary, sensitivity, specifi city, and receiver operating characteristic (ROC) curves. Results: Six manuscripts with 456 subjects (with 623 independent readings)-185 with PSC-met the study inclusion criteria. The summary area under the ROC curve was 0.91. High heterogeneity (inconsistency index, 78%) was found but became moderate (inconsistency index, 36%) with the exclusion of one study in which the diagnostic threshold was set for high sensitivity. There was no evidence of publication bias (P =.27, bias coeffi cient analysis). Sensitivity and specifi city of MRCP for PSC detection across all studies were 0.86 and 0.94, respectively. Positive and negative likelihood ratios with MRCP were 15.3 and 0.15, respectively. In patients with high pretest probabilities, MRCP enabled confi rmation of PSC; in patients with low pretest probabilities, MRCP enabled exclusion of PSC. Worst-case-scenario (pretest probability, 50%) posttest probabilities were 94% and 13% for positive and negative MRCP results, respectively. Conclusion: MRCP has high sensitivity and very high specificity for diagnosis of PSC. In many cases of suspected PSC, MRCP is sufficient for diagnosis, and, thus, the risks associated with ERCP can be avoided. (C) RSNA, 2010
引用
收藏
页码:387 / 396
页数:10
相关论文
共 41 条
[1]
Magnetic resonance cholangiography in patients with biliary disease: its role in primary sclerosing cholangitis [J].
Angulo, P ;
Pearce, DH ;
Johnson, CD ;
Henry, JJ ;
LaRusso, NF ;
Petersen, BT ;
Lindor, KD .
JOURNAL OF HEPATOLOGY, 2000, 33 (04) :520-527
[2]
Barker Fred G 2nd, 2005, Neurosurg Focus, V19, pE5, DOI 10.3171/foc.2005.19.4.6
[3]
Diagnostic accuracy of magnetic resonance and endoscopic retrograde cholangiography in primary sclerosing cholangitis [J].
Berstad, AE ;
Aabakken, L ;
Smith, HJ ;
Aasen, S ;
Boberg, KM ;
Schrumpf, E .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2006, 4 (04) :514-520
[4]
Bivariate meta-analysis of sensitivity and specificity with sparse data: a generalized linear mixed model approach [J].
Chu, Haitao ;
Cole, Stephen R. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2006, 59 (12) :1331-1332
[5]
Systematic reviews in health care - Systematic reviews of evaluations of diagnostic and screening [J].
Deeks, JJ .
BRITISH MEDICAL JOURNAL, 2001, 323 (7305) :157-162
[6]
The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed [J].
Deeks, JJ ;
Macaskill, P ;
Irwig, L .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (09) :882-893
[7]
Conducting systematic reviews of diagnostic studies: Didactic guidelines [J].
Devillé W.L. ;
Buntinx F. ;
Bouter L.M. ;
Montori V.M. ;
De Vet H.C.W. ;
Van Der Windt D.A.W.M. ;
Bezemer P.D. .
BMC Medical Research Methodology, 2 (1) :1-13
[8]
DWAMENA B, 2007, N AM STAT US GROUP M
[9]
MR cholangiography in primary sclerosing cholangitis [J].
Ernst, O ;
Asselah, T ;
Sergent, G ;
Calvo, M ;
Talbodec, N ;
Paris, JC ;
L'Herminé, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (04) :1027-1030
[10]
Potential impact of magnetic resonance cholangiopancreatography on endoscopic retrograde cholangiopancreatography workload and complication rate in patients referred because of abdominal pain [J].
Farrell, RJ ;
Noonan, N ;
Mahmud, N ;
Morrin, MM ;
Kelleher, D ;
Keeling, PWN .
ENDOSCOPY, 2001, 33 (08) :668-675