Safety and Efficacy of Sirolimus-Eluting Stent Implantation in Patients With Acute Coronary Syndrome in the Real World

被引:11
作者
Kawaguchi, Ren [2 ]
Kimura, Takeshi [1 ]
Morimoto, Takeshi [3 ,4 ]
Oshima, Shigeru [2 ]
Hoshizaki, Hiroshi [2 ]
Kawai, Kazuya [5 ]
Shiode, Nobuo [6 ]
Hiasa, Yoshikazu [7 ]
Mitsudo, Kazuaki [8 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Kyoto, Japan
[2] Gunma Prefectural Cardiovasc Ctr, Div Cardiol, Maebashi, Gunma, Japan
[3] Kyoto Univ, Grad Sch Med, Ctr Med Educ, Kyoto, Japan
[4] Kyoto Univ, Grad Sch Med, Clin Epidemiol Unit, Kyoto, Japan
[5] Chikamori Hosp, Div Cardiol, Kochi, Japan
[6] Matsue Red Cross Hosp, Div Cardiol, Matsue, Shimane, Japan
[7] Red Cross Hosp, Div Cardiol, Komatsushima, Japan
[8] Kurashiki Cent Hosp, Div Cardiol, Kurashiki, Okayama, Japan
关键词
ACUTE MYOCARDIAL-INFARCTION; BARE-METAL STENTS; UNCOATED STENTS; THROMBOSIS; PLACEMENT;
D O I
10.1016/j.amjcard.2010.07.035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of drug-eluting stents in patients with acute coronary syndrome (ACS), particularly those with acute myocardial infarction (AMI), is controversial owing to concerns about late adverse events. We evaluated the long-term safety of sirolimus-eluting stent implantation in patients with ACS. Of 10,778 patients treated exclusively with a sirolimus-eluting stent in the j-Cypher registry, the 3-year outcomes of 2,308 patients with ACS (953 patients with AM!) were compared to those of 8,470 patients without ACS. Compared to patients without ACS, the patients with ACS had a significantly greater adjusted risk of death or myocardial infarction (hazard ratio [HR] 1.24, 95% confidence interval [CI] 1.12 to 1.37, p <0.0001) and definite or probable stent thrombosis (HR 1.43, 95% CI 1.11 to 1.82, p = 0.006) within the first year after sirolimus-eluting stent implantation. However, after 1 year, patients with ACS no longer had a greater risk of death or myocardial infarction (HR 1.01, 95% CI 0.90 to 1.13, p = 0.87) and stent thrombosis (HR 1.32, 95% CI 0.92 to 1.86, p = 0.13). Of the patients with ACS, those with AMI had a greater risk of death or myocardial infarction (HR 1.33, 95% CI 1.12 to 1.6, p = 0.001) and stent thrombosis (HR 1.57, 95% CI 1.05 to 2.39, p = 0.03) than those with unstable angina pectoris within the first year. However, they had a similar risk of death or myocardial infarction (HR 1.00, 95% CI 0.78 to 1.22, p = 0.83) and stent thrombosis (HR 0.83, 95% CI 0.38 to 1.6, p = 0.59) after 1 year. The risk of late adverse events >1 year after sirolimus-eluting stent implantation was similar between those with and without ACS and between those with AMI and those with unstable angina pectoris. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:1550-1560)
引用
收藏
页码:1550 / 1560
页数:11
相关论文
共 15 条
[1]   Use of Drug-Eluting Stents in Acute Myocardial Infarction A Systematic Review and Meta-Analysis [J].
Brar, Somjot S. ;
Leon, Martin B. ;
Stone, Gregg W. ;
Mehran, Roxana ;
Moses, Jeffrey W. ;
Brar, Simerjeet K. ;
Dangas, George .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (18) :1677-1689
[2]   ACC/AHA guidelines for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction [J].
Braunwald, E ;
Antman, EM ;
Beasley, JW ;
Califf, RM ;
Cheitlin, MD ;
Hochman, JS ;
Jones, RH ;
Kereiakes, D ;
Kupersmith, J ;
Levin, TN ;
Pepine, CJ ;
Schaeffer, JW ;
Smith, EE ;
Steward, DE ;
Theroux, P ;
Gibbons, RJ ;
Alpert, JS ;
Eagle, KA ;
Faxon, DP ;
Fuster, V ;
Gardner, TJ ;
Gregoratos, G ;
Russell, RO ;
Smith, SC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :970-1056
[3]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[4]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[5]   Comparison of three-year clinical outcome of sirolimus- and paclitaxel-eluting stents versus bare metal stents in patients with ST-segment elevation myocardial infarction (from the RESEARCH and T-SEARCH registries) [J].
Daemen, Joost ;
Tanimoto, Shuzou ;
Garcia-Garcia, Hector M. ;
Kukreja, Neville ;
van de Sande, Meike ;
Sianos, Georgios ;
de Jaegere, Peter P. T. ;
van Domburg, Ron T. ;
Serruys, Patrick W. .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08) :1027-1032
[6]   Coronary angioplasty with or without stent implantation for acute myocardial infarction [J].
Grines, CL ;
Cox, DA ;
Stone, GW ;
Garcia, E ;
Mattos, LA ;
Giambartolomei, A ;
Brodie, BR ;
Madonna, O ;
Eijgelshoven, M ;
Lansky, AJ ;
O'Neill, WW ;
Morice, MC .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (26) :1949-1956
[7]   Antiplatelet Therapy and Stent Thrombosis After Sirolimus-Eluting Stent Implantation [J].
Kimura, Takeshi ;
Morimoto, Takeshi ;
Nakagawa, Yoshihisa ;
Tamura, Toshihiro ;
Kadota, Kazushige ;
Yasumoto, Hitoshi ;
Nishikawa, Hideo ;
Hiasa, Yoshikazu ;
Muramatsu, Toshiya ;
Meguro, Taiichiro ;
Inoue, Naoto ;
Honda, Hidehiko ;
Hayashi, Yasuhiko ;
Miyazaki, Shunichi ;
Oshima, Shigeru ;
Honda, Takashi ;
Shiode, Nobuo ;
Namura, Masanobu ;
Sone, Takahito ;
Nobuyoshi, Masakiyo ;
Kita, Toru ;
Mitsudo, Kazuaki .
CIRCULATION, 2009, 119 (07) :987-U120
[8]   Paclitaxel-eluting versus uncoated stents in primary percutaneous coronary intervention [J].
Laarman, Gerrit J. ;
Suttorp, Maarten J. ;
Dirksen, Maurits T. ;
van Heerebeek, Loek ;
Kiemeneij, Ferdinand ;
Slagboom, Ton ;
van der Wieken, L. Ron ;
Tijssen, Jan G. P. ;
Rensing, Benno J. ;
Patterson, Mark .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (11) :1105-1113
[9]   Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients - An autopsy study [J].
Nakazawa, Gaku ;
Finn, Aloke V. ;
Joner, Michael ;
Ladich, Elena ;
Kutys, Robert ;
Mont, Erik K. ;
Gold, Herman K. ;
Burke, Allen P. ;
Kolodgie, Frank D. ;
Virmani, Renu .
CIRCULATION, 2008, 118 (11) :1138-1145
[10]   Comparison of coronary-artery bypass surgery and stenting for the treatment of multivessel disease. [J].
Serruys, PW ;
Unger, F ;
Sousa, JE ;
Jatene, A ;
Bonnier, HJRM ;
Schonberger, JPAM ;
Buller, N ;
Bonser, R ;
van den Brand, MJB ;
van Herwerden, LA ;
Morel, MAM ;
van Hout, BA .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (15) :1117-1124