Pulmonary nodule detection: Low-dose versus conventional CT

被引:156
作者
Rusinek, H [1 ]
Naidich, DP [1 ]
McGuinness, G [1 ]
Leitman, BS [1 ]
McCauley, DI [1 ]
Krinsky, GA [1 ]
Clayton, K [1 ]
Cohen, H [1 ]
机构
[1] NYU Med Ctr, Dept Radiol, New York, NY 10016 USA
关键词
computed tomography (CT); comparative studies; image quality; lung; nodule; lung neoplasms; CT; diagnosis;
D O I
10.1148/radiology.209.1.9769838
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To quantitate the effectiveness of low-dose computed tomography (CT) in the identification of pulmonary nodules while controlling for anatomic nodule characteristics and to establish what factors lead to reduced diagnostic sensitivity at low-dose CT. MATERIALS AND METHODS: Each of six participating radiologists independently rated 200 image panels by using a four-point confidence scale. Conventional images were obtained at 200 mAs; low-dose images were obtained at 20 mAs. To fully control their characteristics, nodules were simulated with a given diameter, shape, and section thickness while preserving the resolution, noise level, and reconstruction artifacts of the original images. Panels were matched so that nodules on low-dose and conventional images had equivalent sizes, locations, and relationships to blood vessels. RESULTS: Among 864 positive panels, 259 (60%) of 432 low-dose panels and 272 (63%) of 432 conventional panels were correctly interpreted (P = .259). Lowering the x-ray dose significantly reduced the detectability of peripheral nodules (P = .019) and nodules separated from blood vessels (P = .044). Surprisingly, 3-mm nodules were detected with approximately equal sensitivity (P = .181) at conventional and low-dose CT. The specificity of low-dose images was 88% (148 of 168 panels) versus 91% (153 of 168 panels) for conventional images (P = .372). CONCLUSION: Low-dose CT is acceptable for pulmonary nodule identification, making it suitable for primary screening. These results confirm the strong effect of size, location, and angiocentricity on the sensitivity of nodule detection with conventional CT.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 17 条
  • [1] PULMONARY NODULES - EFFECT OF INCREASED DATA SAMPLING ON DETECTION WITH SPIRAL CT AND CONFIDENCE IN DIAGNOSIS
    BUCKLEY, JA
    SCOTT, WW
    SIEGELMAN, SS
    KUHLMAN, JE
    URBAN, BA
    BLUEMKE, DA
    FISHMAN, EK
    [J]. RADIOLOGY, 1995, 196 (02) : 395 - 400
  • [2] Cohen J, 1977, STAT POWER ANAL BEHA, P179, DOI [10.1016/b978-0-12-179060-8.50011-6, DOI 10.1016/B978-0-12-179060-8.50011-6, DOI 10.1016/B978-0-12-179060-8.50011]
  • [3] PULMONARY NODULES - IMPROVED DETECTION WITS VASCULAR SEGMENTATION AND EXTRACTION WITH SPIRAL CT
    CROISILLE, P
    SOUTO, M
    COVA, M
    WOOD, S
    AFEWORK, Y
    KUHLMAN, JE
    ZERHOUNI, EA
    [J]. RADIOLOGY, 1995, 197 (02) : 397 - 401
  • [4] Low-dose computed tomography of the thorax. Experimental and clinical investigations
    Diederich, S
    Lenzen, H
    Puskas, Z
    Koch, AT
    Yelbuz, TM
    Eameri, M
    Roos, N
    Peters, PE
    [J]. RADIOLOGE, 1996, 36 (06): : 475 - 482
  • [5] A COMPARISON OF RADIATION-DOSES TO THE BREAST IN COMPUTED TOMOGRAPHIC CHEST EXAMINATIONS FOR 2 SCANNING PROTOCOLS
    EVANS, SH
    DAVIS, R
    COOKE, J
    ANDERSON, W
    [J]. CLINICAL RADIOLOGY, 1989, 40 (01) : 45 - 46
  • [6] Incidence of lung nodules found in patients undergoing lung volume reduction
    Hazelrigg, SR
    Boley, TM
    Weber, D
    Magee, MJ
    Naunheim, KS
    [J]. ANNALS OF THORACIC SURGERY, 1997, 64 (02) : 303 - 306
  • [7] CHRONIC INFILTRATIVE LUNG-DISEASE - COMPARISON OF DIAGNOSTIC ACCURACIES OF RADIOGRAPHY AND LOW-AND CONVENTIONAL-DOSE THIN-SECTION CT
    LEE, KS
    PRIMACK, SL
    STAPLES, CA
    MAYO, JR
    ALDRICH, JE
    MULLER, NL
    [J]. RADIOLOGY, 1994, 191 (03) : 669 - 673
  • [8] Simulated dose reduction in conventional chest CT: Validation study
    Mayo, JR
    Whittall, KP
    Leung, AN
    Hartman, TE
    Park, CS
    Primack, SL
    Chambers, GK
    Limkeman, MK
    Toth, TL
    Fox, SH
    [J]. RADIOLOGY, 1997, 202 (02) : 453 - 457
  • [9] HIGH-RESOLUTION CT OF THE CHEST - RADIATION-DOSE
    MAYO, JR
    JACKSON, SA
    MULLER, NL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 479 - 481
  • [10] Milla N, 1994, Nagoya J Med Sci, V57, P127