Non-invasive evaluation of coronary artery stent patency with retrospectively ECG-gated 64-slice CT angiography

被引:50
作者
Carbone, Iacopo [1 ]
Francone, Marco [1 ]
Algeri, Emanuela [1 ]
Granatelli, Antonino [2 ]
Napoli, Alessandro [1 ]
Kirchin, Miles A. [3 ]
Catalano, Carlo [1 ]
Passariello, Roberto [1 ]
机构
[1] Univ Roma La Sapienza, Dept Radiol Sci, Rome, Italy
[2] San Giovanni Evangelista Hosp, Dept Cardiol, Tivoli RM, Italy
[3] Bracco Imaging, Worldwide Med Affairs, Milan, Italy
关键词
coronary artery; stents; multi-slice computed tomography; coronary restenosis; coronary angiography;
D O I
10.1007/s00330-007-0756-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of our study has been to evaluate the ability of 64-slice computed tomographic angiography (CTA) to assess coronary artery stent patency, relative to selective coronary angiography (SCA). Fifty-five consecutive patients (age range 45-80 years) with 97 previously implanted coronary artery stents underwent 64-slice CTA. The 55 patients comprised 40 subjects (group A) who were referred for follow-up SCA at a mean interval of 9.6 months after stent positioning, and 15 subjects (group B) in whom SCA was clinically indicated. Stent evaluation was performed independently by two blinded readers in terms of image quality and presence of in-stent restenosis (ISR; lumen obstruction of >= 50%). SCA was performed in 41/55 patients; 14 patients refused to undergo SCA after the 64-slice CTA exam. A total of 88 stents in 74 segments were analyzed. Twenty-one of the 74 stented segments were of poor image quality and were not considered for further analysis. Sixty-four-slice CTA detected 12/16 ISR (sensitivity: 75%) and ruled out ISR in 32/37 cases (specificity: 86%). Sixty-four-slice CTA is a valuable modality for follow-up of coronary artery stent patency only in selected patients. Appropriate candidates for follow-up 64-slice CTA should be established based on stent diameter, stent material and type as well as HR and heart rhythm. However, given the number of non-assessable segments, further work would appear necessary before 64-slice CTA can be considered a suitable procedure for broad clinical application in the evaluation of coronary artery stent patency.
引用
收藏
页码:234 / 243
页数:10
相关论文
共 48 条
[1]   Restenosis after coronary stenting in current clinical practice [J].
Antoniucci, D ;
Valenti, R ;
Santoro, GM ;
Bolognese, L ;
Trapani, M ;
Cerisano, G ;
Boddi, V ;
Fazzini, PF .
AMERICAN HEART JOURNAL, 1998, 135 (03) :510-518
[2]   Radiation dose in multidetector row computed tomography cardiac imaging [J].
Bae, KT ;
Hong, C ;
Whiting, BR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) :859-863
[3]   Usefulness of multislice computed tomographic coronary angiography to assess in-stent restenosis [J].
Cademartiri, F ;
Mollet, N ;
Lemos, PA ;
Pugliese, F ;
Baks, T ;
McFadden, EP ;
Krestin, GP ;
de Feyter, PJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (06) :799-802
[4]   Evaluation of in-stent restenosis in proximal coronary arteries with multidetector computed tomography (MDCT) [J].
Chabbert, V. ;
Carrie, D. ;
Bennaceur, M. ;
Maupas, E. ;
Lauwers, V. ;
Mhem, M. ;
Lhermusier, T. ;
Elbaz, M. ;
Joffre, F. ;
Rousseau, H. ;
Puel, J. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1452-1463
[5]  
*CRIT COMM AM HEAR, 1994, NOM CRIT DIAGN DIS H
[6]  
DEBONO D, 1993, BRIT HEART J, V70, P297
[7]   Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population - Comparison with conventional invasive angiography [J].
Ehara, M ;
Surmely, JF ;
Kawai, M ;
Katoh, O ;
Matsubara, T ;
Terashima, M ;
Tsuchikane, E ;
Kinoshita, Y ;
Suzuki, T ;
Ito, T ;
Takeda, Y ;
Nasu, K ;
Tanaka, N ;
Murata, A ;
Suzuki, Y ;
Sato, K ;
Suzuki, T .
CIRCULATION JOURNAL, 2006, 70 (05) :564-571
[8]   Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography - Comparison with invasive coronary angiography [J].
Ehara, Mariko ;
Kawai, Masato ;
Surmely, Jean-Francois ;
Matsubara, Tetsuo ;
Terashima, Mitsuyasu ;
Tsuchikane, Etsuo ;
Kinoshita, Yoshihisa ;
Ito, Tatsuya ;
Takeda, Yoshihiro ;
Nasu, Kenya ;
Tanaka, Nobuyoshi ;
Murata, Akira ;
Fujita, Hiroshi ;
Sato, Koyo ;
Kodama, Atsuko ;
Katoh, Osamu ;
Suzuki, Takahiko .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) :951-959
[9]  
Fleiss JL., 2003, STAT METHODS RATES P, P598, DOI 10.1002/0471445428
[10]   First performance evaluation of a dual-source CT (DSCT) system (vol 16, pg 256, 2006) [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (06) :1405-1405