Attenuation of conducted EMI emissions from an inverter-driven motor

被引:213
作者
Akagi, Hirofumi [1 ]
Shimizu, Takayuki [1 ]
机构
[1] Tokyo Inst Technol, Dept Elect & Elect Engn, Tokyo 152, Japan
关键词
electromagnetic interference (EMI); leakage currents; motor drives; pulsewidth modulation (PWM) inverters;
D O I
10.1109/TPEL.2007.911878
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper provides theoretical and experimental discussions on conducted electromagnetic interference (EMI) emissions from an inverter-driven motor rated at 400 V and 15 kW. It focuses on a line EMI filter and its combination with a motor EMI filter, along with their effects on attenuation of, conducted emission voltage. When no EMI filter is connected, the motor drive cannot meet the conducted emission limits prescribed by Category 3 in the IEC61800-3 regulations. The reason is that the common-mode voltage generated by a voltage-source pulse width modulation (PWM) inverter causes a common-mode leakage current flowing into the ground wire lead through parasitic capacitors inside the motor. When the line EMI filter is connected, the motor drive can meet Category 3. The motor EMI,filter eliminates the common-mode voltage from the motor terminals, thus bringing a drastic reduction to the leakage current. The combination of the two EMI filters can comply with the limits prescribed by Category 2, which are much stricter than those by Category 3.
引用
收藏
页码:282 / 290
页数:9
相关论文
共 22 条
[1]   A passive EMI filter for preventing high-frequency leakage current from flowing through the grounded inverter heat sink of an adjustable-speed motor drive system [J].
Akagi, H ;
Doumoto, T .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1215-1223
[2]   An approach to eliminating high-frequency shaft voltage and ground leakage current from an inverter-driven motor [J].
Akagi, H ;
Doumoto, T .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (04) :1162-1169
[3]   Design and performance of a passive EMI filter for use with a voltage-source PWM inverter having sinusoidal output voltage and zero common-mode voltage [J].
Akagi, H ;
Hasegawa, H ;
Doumoto, T .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (04) :1069-1076
[4]   A passive EMI filter for eliminating both bearing current and ground leakage current from an inverter-driven motor [J].
Akagi, Hirofumi ;
Tamura, Shunsuke .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (05) :1459-1469
[5]  
Finlayson P. T., 1998, IEEE Industry Applications Magazine, V4, P46, DOI 10.1109/2943.644886
[6]  
GUBISCH RW, 1998, COMPLIANCE ENG E JAN, P46
[7]   Design and implementation of an inverter output LC filter used for DV/DT reduction [J].
Habetler, TG ;
Naik, R ;
Nondahl, TA .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2002, 17 (03) :327-331
[8]   An EMC evaluation of the use of unshielded motor cables in AC adjustable speed drive applications [J].
Hanigovszki, N ;
Landkildehus, J ;
Spiazzi, G ;
Blaabjerg, F .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (01) :273-281
[9]   Elimination of common-mode voltage in three-phase sinusoidal power converters [J].
Julian, AL ;
Oriti, G ;
Lipo, TA .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (05) :982-989
[10]   Common mode current paths and their modeling in PWM inverter-fed drives [J].
Kempski, A ;
Smolenski, R ;
Strzelecki, R .
PESC'02: 2002 IEEE 33RD ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2002, :1551-1556