Sustained suppression of neointimal proliferation by sirolimus-eluting stents - One-year angiographic and intravascular ultrasound follow-up

被引:491
作者
Sousa, JE
Costa, MA
Abizaid, AC
Rensing, BJ
Abizaid, AS
Tanajura, LF
Kozuma, K
Van Langenhove, G
Sousa, AGMR
Falotico, R
Jaeger, J
Popma, JJ
Serruys, PW
机构
[1] Inst Dante Pazzanese Cardiol, BR-04012180 Sao Paulo, Brazil
[2] Univ Hosp Dijkzigt, Ctr Thorax, NL-3015 GD Rotterdam, Netherlands
[3] Johnson & Johnson Co, Warren, NJ USA
[4] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
angiography; drugs; stents; restenosis; ultrasonics;
D O I
10.1161/hc4201.098056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-We have previously reported a virtual absence of neointimal hyperplasia 4 months after implantation of sirolimus-eluting stents. The aim of the present investigation was to determine whether these results are sustained over a period of 1 year. Methods and Results-Forty-five patients with de novo coronary disease were successfully treated with the implantation of a single sirolimus-eluting Bx VELOCITY stent in Sao Paulo, Brazil (n=30, 15 fast release [group I, GI] and 15 slow release [GII]) and Rotterdam, The Netherlands (15 slow release, GIII). Angiographic and volumetric intravascular ultrasound (IVUS) follow-up was obtained at 4 and 12 months (GI and GII) and 6 months (GIII). In-stent minimal lumen diameter and percent diameter stenosis remained essentially unchanged in all groups (at 12 months, GI and GII; at 6 months, GIII). Follow-up in-lesion minimal lumen diameter was 2.28 mm (GIII), 2.32 mm (GI), and 2.48 mm (GII). No patient approached the greater than or equal to 50% diameter stenosis at I year by angiography or IVUS assessment, and no edge restenosis was observed. Neointimal hyperplasia, as detected by IVUS, was virtually absent at 6 months (2 +/-5% obstruction volume, GIII) and at 12 months (GI=2 +/-5% and GII=2 +/-3%). Conclusions-This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.
引用
收藏
页码:2007 / 2011
页数:5
相关论文
共 19 条
  • [1] Late coronary occlusion after intracoronary brachytherapy
    Costa, MA
    Sabaté, M
    van der Giessen, WJ
    Kay, IP
    Cervinka, P
    Ligthart, JMR
    Serrano, P
    Coen, VLMA
    Levendag, PC
    Serruys, PW
    [J]. CIRCULATION, 1999, 100 (08) : 789 - 792
  • [2] Three-dimensional intravascular ultrasonic volumetric quantification of stent recoil and neointimal formation of two new generation tubular stents
    Costa, MA
    Sabate, M
    Kay, IP
    de Feyter, PJ
    Kozuma, K
    Serrano, P
    de Valk, V
    Albertal, M
    Ligthart, JMR
    Disco, C
    Foley, DP
    Serruys, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (02) : 135 - 139
  • [3] Ellis SG, 1999, CIRCULATION, V100, P799
  • [4] Inhibition of intimal thickening after balloon angioplasty in porcine coronary arteries by targeting regulators of the cell cycle
    Gallo, R
    Padurean, A
    Jayaraman, T
    Marx, S
    Rogue, M
    Adelman, S
    Chesebro, J
    Fallon, J
    Fuster, V
    Marks, A
    Badimon, JJ
    [J]. CIRCULATION, 1999, 99 (16) : 2164 - 2170
  • [5] Screening of ruptured plaques in patients with coronary artery disease by intravascular ultrasound
    Ge, J
    Chirillo, F
    Schwedtmann, J
    Görge, G
    Haude, M
    Baumgart, D
    Shah, V
    von Birgelen, C
    Sack, S
    Boudoulas, H
    Erbel, R
    [J]. HEART, 1999, 81 (06) : 621 - 627
  • [6] Rapamycin blocks IL-2-driven T cell cycle progression while preserving T cell survival
    Gonzalez, J
    Harris, T
    Childs, G
    Prystowsky, MB
    [J]. BLOOD CELLS MOLECULES AND DISEASES, 2001, 27 (03) : 572 - 585
  • [7] RAPAMYCIN INHIBITS ARTERIAL INTIMAL THICKENING CAUSED BY BOTH ALLOIMMUNE AND MECHANICAL INJURY - ITS EFFECT ON CELLULAR, GROWTH-FACTOR, AND CYTOKINE RESPONSES IN INJURED VESSELS
    GREGORY, CR
    HUIE, P
    BILLINGHAM, ME
    MORRIS, RE
    [J]. TRANSPLANTATION, 1993, 55 (06) : 1409 - 1418
  • [8] Sirolimus (rapamycin)-based therapy in human renal transplantation -: Similar efficacy and different toxicity compared with cyclosporine
    Groth, CG
    Bäckman, L
    Morales, JM
    Calne, R
    Kreis, H
    Lang, P
    Touraine, JL
    Claesson, K
    Campistol, JM
    Durand, D
    Wramner, L
    Brattström, C
    Charpentier, B
    [J]. TRANSPLANTATION, 1999, 67 (07) : 1036 - 1042
  • [9] Positive geometric vascular remodeling is seen after catheter-based radiation followed by conventional stent implantation but not after radioactive stent implantation
    Kay, IP
    Sabaté, M
    Costa, MA
    Kozuma, K
    Albertal, M
    van der Giessen, WJ
    Wardeh, AJ
    Ligthart, JMR
    Coen, VMA
    Levendag, PC
    Serruys, PW
    [J]. CIRCULATION, 2000, 102 (12) : 1434 - 1439
  • [10] Kay IP, 2001, CIRCULATION, V103, P14