Hepatitis B virus markers in anti-HBc only positive individuals

被引:113
作者
Weber, B [1 ]
Melchior, W
Gehrke, R
Doerr, HW
Berger, A
Rabenau, H
机构
[1] Ctr Langweis, Lab Reunis Kutter Lieners Hastert, L-6131 Junglinster, Luxembourg
[2] Univ Klin Frankfurt, Inst Med Virol, Frankfurt, Germany
[3] Roche Diagnost, Penzberg, Germany
关键词
HBsAg mutants; low-level HBsAg carriers; immune complexes; viral load; anti HBs test variability;
D O I
10.1002/jmv.1052
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Isolated reactivity to hepatitis B virus (HBV) core antigen (anti-HBc) is observed relatively frequently in immunocompromised individuals, intravenous drug abusers (IVDA), and in the presence of HCV infection. The reason for the lack of HBsAg is not clear. The aim of the present study was to investigate which factors (genetic variability of S gene, low-level HBsAg, and immune complexes may be responsible for the failure of HBsAS detection with commercial HBsAg screening assays. Dilution series of two recombinant HBsAg escape mutants and dilutions of serum samples from chronic HBV carriers with multiple insertions in the a determinant and different HBsAg subtypes were tested with a highly sensitive assay that detects wild-type HBsAS (Elecsys HBsAg, Roche Diagnostics, Penzberg, Germany) and two assays that detect HBV wild-type and escape mutants (Murex HBsAS Version 3, Murex and Enzygnost HBsAg 5.0, Dade Behring, Marburg, Germany). Elecsys HBsAg showed in comparison to Murex HBsAg Version 3 and Enzygnost HBsAg 5.0 a reduced sensitivity for escape mutant detection. On the other hand, the best performance for HBsAg subtype detection was obtained with Elecsys HBsAS. In the second part of the study, a selected panel of isolated anti-HBc reactive (n=104) serum samples (AxSYM Core) was submitted to testing by Elecsys HBsAg, Murex HBsAS Version 3, Enzygnost HBsAg 5.0, and HBsAS detection after immune complex dissociation (ICD) and anti-HBs determination with two different assays (AxSYM Ausab and Elecsys Anti-HBs). To assess the specificity of anti-HBc test results, all the samples were tested by a second anti-HBc assay (Elecsys Anti-HBc). Quantitative HBV DNA detection was undertaken with a commercially available HBV PCR assay (Amplicor HBV Monitor). HCV infection was present in 65.4% of anti-HBc only reactive individuals. Five AxSYM Core positive samples were negative by Elecsys Anti- HBc. Overall, 15(14.4%) AxSYM Ausab negative samples gave positive results with Elecsys Anti-HBs (median value: 21 IU/ml). No low-level HBsAg carrier was detected among the isolated anti-HBc reactive individuals with Elecsys HBsAg. There was no evidence for the presence of immune complexes. Only one sample was repeatedly reactive by the Murex HBsAg, suggesting that the a mutant form of HBsAg was responsible for the isolated anti-HBc reactivity, however neutralisation assay was not interpretable and HBV DNA PCR was negative. Fifteen (14.4%) anti-HBc only positive individuals were HBV DNA carriers with concentrations ranging from 800 to more than > 4,000,000 copies of viral DNA/ml. In conclusion, the most probable explanations for isolated anti-HBc reactivity in our study group are a possible interference of HBsAg synthesis by HCV infection (65.4%) and divergence of results of anti-HBs assays (14.4%). There is no evidence for the presence of low-level HBsAg carriers and immune complexes. HBsAg mutants cannot be excluded definitively by the test strategy used in the present evaluation. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:312 / 319
页数:8
相关论文
共 48 条
[1]   ENHANCEMENT OF HBSAG DETECTION IN SERUM OF PATIENTS WITH CHRONIC LIVER-DISEASE FOLLOWING REMOVAL OF CIRCULATING IMMUNE-COMPLEXES [J].
ACKERMAN, Z ;
WANDS, JR ;
GAZITT, Y ;
BRECHOT, C ;
KEW, MC ;
SHOUVAL, D .
JOURNAL OF HEPATOLOGY, 1994, 20 (03) :398-404
[2]   Reactivation of hepatitis B in a long-term anti-HBs-positive patient with AIDS following lamivudine withdrawal [J].
Altfeld, M ;
Rockstroh, JK ;
Addo, M ;
Kupfer, B ;
Pult, I ;
Will, H ;
Spengler, U .
JOURNAL OF HEPATOLOGY, 1998, 29 (02) :306-309
[3]   MONITORING THE NATURAL COURSE AND RESPONSE TO THERAPY OF CHRONIC HEPATITIS-B WITH AN AUTOMATED SEMIQUANTITATIVE ASSAY FOR IGM ANTI-HBC [J].
BRUNETTO, MR ;
CERENZIA, MT ;
OLIVERI, F ;
PIANTINO, P ;
RANDONE, A ;
CALVO, PL ;
MANZINI, P ;
ROCCA, G ;
GALLI, C ;
BONINO, F .
JOURNAL OF HEPATOLOGY, 1993, 19 (03) :431-436
[4]   Occult hepatitis B virus infection in patients with chronic hepatitis C liver disease [J].
Cacciola, I ;
Pollicino, T ;
Squadrito, G ;
Cerenzia, G ;
Orlando, ME ;
Raimondo, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (01) :22-26
[5]  
Carman W.F., 1997, VIRAL HEPATITIS LIVE, P108
[6]   Hepatitis B virus envelope variation after transplantation with and without hepatitis B immune globulin prophylaxis [J].
Carman, WF ;
Trautwein, C ;
vanDeursen, FJ ;
Colman, K ;
Dornan, E ;
McIntyre, G ;
Waters, J ;
Kliem, V ;
Muller, R ;
Thomas, HC ;
Mannis, MP .
HEPATOLOGY, 1996, 24 (03) :489-493
[7]  
Carman WF, 1997, HEPATOLOGY, V26, P1658, DOI 10.1002/hep.510260640
[8]   UNSATISFACTORY SPECIFICITIES AND SENSITIVITIES OF 6 ENZYME IMMUNOASSAYS FOR ANTIBODIES TO HEPATITIS-B CORE ANTIGEN [J].
CASPARI, G ;
BEYER, HJ ;
ELBERT, G ;
KOERNER, K ;
MUSS, P ;
SCHUNTER, FW ;
UY, A ;
GERLICH, W ;
THOMSSEN, R ;
SCHMITT, H .
JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (09) :2067-2072
[9]   Low-level viremia and intracellular expression of hepatitis B surface antigen (HBsAg) in HBsAg carriers with concurrent hepatitis C virus infection [J].
Chu, CM ;
Yeh, CT ;
Liaw, WF .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (07) :2084-2086
[10]   Infectivity of hepatic allografts with antibodies to hepatitis B virus [J].
Dodson, SF ;
Issa, S ;
Araya, V ;
Gayowski, T ;
Pinna, A ;
Eghtesad, B ;
Iwatsuki, S ;
Montalvo, E ;
Rakela, J ;
Fung, JJ .
TRANSPLANTATION, 1997, 64 (11) :1582-1584