Quantification of sifuvirtide in monkey plasma by an on-line solid-phase extraction procedure combined with liquid chromatography/electrospray ionization tandem mass spectrometry

被引:26
作者
Dai, SJ
Song, HF
Dou, GF
Qian, XH [1 ]
Zhang, YJ
Cai, Y
Liu, XW
Tang, ZM
机构
[1] Beijing Inst Radiat Med, Lab Genom & Proteom, Beijing 100850, Peoples R China
[2] Beijing Inst Radiat Med, Lab Drug Metab & Pharmacokinet, Beijing 100850, Peoples R China
[3] Beijing Inst Transfus Med, Lab Drug Metab & Pharmacokinet, Beijing 1000850, Peoples R China
关键词
D O I
10.1002/rcm.1917
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, automated and rapid method has been developed for the determination of a novel antiviral peptide sifuvirtide in monkey plasma. Raw plasma samples were directly loaded onto an online solid-phase extraction (SPE) column, which removes the time-consuming and laborious sample pretreatment. Following a timed valve-switching event, the analyte was eluted on-line to a reversed-phase high-performance liquid chromatography (RP-HPLC) column and subsequently introduced into a linear ion trap mass spectrometer, LTQ-MS, via an electrospray ionization (ESI) interface. The multiply charged peptides were specified and quantitatively analyzed using selective reaction monitoring (SRM). A highly pure four iodine-sifuvirtide was synthesized using an optimized iodogen method and proved to be a suitable internal standard (IS). A single analysis run takes about 18min. Validation of the method demonstrated that the linear calibration curves covered the range of 4.88-5000 ng/mL, and the correlation coefficients were above 0.9923. The limit of detection (LOD) with the signal-to-noise (S/N) ratio higher than 12 was calculated as 1.22 ng/mL. The intra- and inter-batch precisions were less than 12.7% and 9.1%, and the mean accuracy ranged from -5.2% to 3.6%, respectively. Any carry-over effect from the system was negligible. In a pharmacokinetic (PK) study of sifuvirtide after a single intravenous or subcutaneous dose in monkeys, the on-line SPE-LC/MS/MS system was successfully utilized to determine hundreds of samples with only one extraction column, which indicated the feasibility and the reliability of this method for application in preclinical and clinical PK studies of peptide drugs. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:1273 / 1282
页数:10
相关论文
共 17 条
[1]   AUTOMATIC SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF QUINIDINE IN PLASMA [J].
BRANDSTETEROVA, E ;
ROMANOVA, D ;
KRALIKOVA, D ;
BOZEKOVA, L ;
KRISKA, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (01) :101-104
[2]   Clinical management of treatment-experienced, HIV-infected patients with the fusion inhibitor enfuvirtide: consensus recommendations [J].
Clotet, B ;
Raffi, F ;
Cooper, D ;
Delfraissy, JF ;
Lazzarin, A ;
Moyle, G ;
Rockstroh, J ;
Soriano, V ;
Schapiro, J .
AIDS, 2004, 18 (08) :1137-1146
[3]   An advanced double column-switching technique (LC-LC) for liquid chromatography/electrospray ionisation tandem mass spectrometry for fully automated analysis of caspofungin [J].
Egle, H ;
Trittler, R ;
Kümmerer, K .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (23) :2871-2877
[4]   Enfuvirtide: First fusion inhibitor for treatment of HIV infection [J].
Jamjian, MC ;
McNicholl, IR .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2004, 61 (12) :1242-1247
[5]  
Jemal M, 2000, BIOMED CHROMATOGR, V14, P422, DOI 10.1002/1099-0801(200010)14:6<422::AID-BMC25>3.0.CO
[6]  
2-I
[7]   A strategy of plasma protein quantitation by selective reaction monitoring of an intact protein [J].
Ji, QC ;
Rodila, R ;
Gage, EM ;
El-Shourbagy, TA .
ANALYTICAL CHEMISTRY, 2003, 75 (24) :7008-7014
[8]   Method development for the concentration determination of a protein in human plasma utilizing 96-well solid phase extraction and liquid chromatography/tandem mass spectrometric detection [J].
Ji, QC ;
Gage, EM ;
Rodila, R ;
Chang, MS ;
El-Shourbagy, TA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (08) :794-799
[9]   Analytical procedures for quantification of peptides in pharmaceutical research by liquid chromatography-mass spectrometry [J].
John, H ;
Walden, M ;
Schäfer, S ;
Genz, S ;
Forssmann, WG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (04) :883-897
[10]   Simultaneous determination of four immunosuppressants by means of high speed and robust on-line solid phase extraction-high performance liquid chromatography-tandem mass spectrometry [J].
Koal, T ;
Deters, M ;
Casetta, B ;
Kaever, V .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02) :215-222