Experimental studies of the JET NBI neutraliser plasma

被引:13
作者
Crowley, B [1 ]
Surrey, E
Cox, SJ
Ciric, D
Ellingboe, AR
机构
[1] Dublin City Univ, EURATOM Assoc, Plant Res Lab, Dublin 9, Ireland
[2] UKAEA Euratom Fus Assoc, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
关键词
JET NBI; neutralisation efficiency; hydrogen ion beams;
D O I
10.1016/S0920-3796(03)00154-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Neutralisation efficiency is an important issue in the design of neutral beam injection (NBI) systems for heating and fuelling fusion plasmas. The JET Neutral Beam Injectors system does not reach the efficiency that is expected on the basis of current understanding of the neutralisation process. If this neutralisation efficiency deficit could be eliminated by re-design of the neutralisers, additional neutral beam heating power would become available. The interaction of the high-energy beam ions and the gas in the neutraliser cell results in the partial neutralisation of the beam and also in the formation of a low temperature plasma inside the neutraliser. The interaction between this plasma, the neutral gas and the walls of the cell can give rise to various phenomena capable of depleting the neutral gas molecular density hence reducing the effective neutralisation target. This paper presents the results of a number of experiments that were carried out in order to measure the plasma and gas parameters inside the neutraliser. The plasma parameters were obtained using a combination of planar Langmuir probes and a novel electrical diagnostic called a 'plasma eater'. The gas pressure was measured using hot cathode ionisation gauges and capacitance manometers. An attempt has been made to measure the neutral hydrogen gas temperature using a spectroscopic technique that requires the measurement of the intensities of the spectral lines of the hydrogen Fulcher-alpha system [Plasma Sources Sci. Technol. 10 (2001) 17]. (C) 2003 B. Crowley. Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 8 条
[1]   CHARGED FUSION PRODUCT ANALYSIS AS DIAGNOSTICS IN HIGH-ENERGY DEUTERIUM BEAMS [J].
BAYETTI, P ;
BOTTIGLIONI, F ;
MARTIN, G ;
PAMELA, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (01) :62-66
[2]  
DEGRAAF M, 1994, THESIS TU EINDHOVEN
[3]  
FALTER HD, JETR98
[4]  
Huddlestone R. H., 1965, Plasma Diagnostic Techniques
[5]  
JONES EM, 1977, 175 CLMR
[6]   GAS HEATING EFFECTS IN THE NEUTRALIZERS OF NEUTRAL BEAM INJECTION LINES [J].
PAMELA, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (06) :1066-1068
[7]  
PAMELA J, 1985, EURCEAFC1279 CEN
[8]  
SURREY E, 2002, P 19 SOFE ATL CIT JA