Generalizability of in-shoe peak pressure measures using the F-scan system

被引:75
作者
Mueller, MJ [1 ]
Strube, MJ [1 ]
机构
[1] UNIV WASHINGTON,DEPT PSYCHOL,ST LOUIS,MO
关键词
foot; reliability; pressure; gait analysis;
D O I
10.1016/0268-0033(95)00047-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In-shoe pressure analysis can be useful in the management of a variety of foot and ankle problems, but guidelines are needed to determine the practical limitations of the measures. The primary purpose of this study was to determine the reliability of peak plantar pressures taken with the F-Scan system over multiple steps, sensors, and days, and using a force platform for additional calibration. Data were collected on 10 healthy subjects as they walked across a force platform for a minimum of three trials on four separate sessions that were 1 week apart. Using a mean of three steps with a single sensor on 1 day, generalizability coefficients were 0.75 for manufacturer calibration and 0.82 with force platform calibration; reliability coefficients for absolute decisions (index of dependability) were 0.60 for manufacturer calibration and 0.76 with force platform calibration. Force measures from the F-Scan and force platform were highly correlated (r = 0.93), but the absolute difference between the measures varied between sensors and over time. Relevance-Peak pressure measures taken from a mean of three steps with procedures outlined by the F-Scan manufacturer provide pressure values that demonstrate adequate reliability for clinical and research purposes when rank ordering of measures is indicated, If measures are to be used for making absolute decisions (e.g., identifying a threshold for injury), calibration from a stable source such as a force platform is recommended.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 14 条
[1]  
BIRKE JA, 1994, LEPROSY REV, V65, P262
[2]  
BRENNAN RL, 1983, ELEMENTS GENERALIZAB
[3]  
CAVANAGH P.R., 1992, INT J CLIN FOOT SCI, V2, P185, DOI [10.1016/0958-2592(92)90047-S, DOI 10.1016/0958-2592(92)90047-S, 10.1016/0958-2592, DOI 10.1016/0958-2592]
[4]   SHIN SPLINTS AND FOREFOOT CONTACT RUNNING - A CASE-REPORT [J].
CIBULKA, MT ;
SINACORE, DR ;
MUELLER, MJ .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 20 (02) :98-102
[5]  
CRONBACH LJ, 1972, DEPENDABILITY BEHAVI
[6]   PRACTICAL CONSIDERATIONS FOR THE USE OF THE PEDOBAROGRAPH [J].
HOLMES, GB ;
TIMMERMAN, L ;
WILLITS, NH .
FOOT & ANKLE, 1991, 12 (02) :105-108
[7]   RELIABILITY OF PRESSURE MEASUREMENTS - THE EMED F SYSTEM [J].
HUGHES, J ;
PRATT, L ;
LINGE, K ;
CLARK, P ;
KLENERMAN, L .
CLINICAL BIOMECHANICS, 1991, 6 (01) :14-18
[8]   IN-SHOE PLANTAR MEASUREMENT WITH TEKSCAN SENSOR SYSTEM [J].
KOCH, M .
BIOMEDIZINISCHE TECHNIK, 1993, 38 (10) :243-248
[9]   RIGID VERSUS SOFT FOOT ORTHOSES - A SINGLE SUBJECT DESIGN [J].
MCPOIL, TG ;
CORNWALL, MW .
JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1991, 81 (12) :638-642
[10]  
Mooney C. Z., 1993, Bootstrapping: A nonparametric approach to statistical inference. sage