Measurement of ventricular torsion by two-dimensional ultrasound speckle tracking imaging

被引:655
作者
Notomi, Y
Lysyansky, P
Setser, RM
Shiota, T
Popovic, ZB
Martin-Miklovic, MG
Weaver, JA
Oryszak, SJ
Greenberg, NL
White, RD
Thomas, JD
机构
[1] Cleveland Clin Fdn, Dept Cardiovasc Med F15, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
[3] GE Ultrasoud Israel Ltd, Tirat Karmel, Israel
基金
美国国家航空航天局;
关键词
D O I
10.1016/j.jacc.2005.02.082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to examine the accuracy/consistency of a novel ultrasound speckle tracking imaging (STI) method for left ventricular torsion (LVtor) measurement in comparison with tagged magnetic resonance imaging (MRI) (a time-domain method similar to STI) and Doppler tissue imaging (DTI) (a velocity-based approach). BACKGROUND Left ventricular torsion from helically oriented myofibers is a key parameter of cardiac performance but is difficult to measure. Ultrasound STI is potentially suitable for measurement of angular motion because of its angle-independence. METHODS We acquired basal and apical short-axis left ventricular (LV) images in 15 patients to estimate LVtor by STI and compare it with tagged MRI and DTI Left ventricular torsion was defined as the net difference of LV rotation at the basal and apical planes. For the STI analysis, we used high-frame (104 +/- 12 frames/s) second harmonic two-dimensional images. RESULTS Data on 13 of 15 patients were usable for STI analysis, and LVtor profile estimated by STI strongly correlated with those by tagged MRI (y = 0.95x + 0.19, r = 0.93, p < 0.0001, analyzed by repeated-measures regression models). The STI torsional velocity profile also correlated well with that by the DTI method (y = 0.79x + 2.4, r = 0.76, p < 0.0001, by repeated-measures regression models) with acceptable bias. CONCLUSIONS The STI estimation of LVtor is concordant with those analyzed by tagged MRI (data derived from tissue displacement) and also showed good agreement with those by DTI (data derived from tissue velocity). Ultrasound STI is a promising new method to assess LV torsional deformation and may make the assessment more available in clinical and research cardiology. (c) 2005 by the American College of Cardiology Foundation.
引用
收藏
页码:2034 / 2041
页数:8
相关论文
共 41 条
  • [1] MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES
    ALTMAN, DG
    BLAND, JM
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) : 307 - 317
  • [2] TORSION OF THE LEFT-VENTRICLE DURING THE EJECTION PHASE IN THE INTACT DOG
    ARTS, T
    MEERBAUM, S
    RENEMAN, RS
    CORDAY, E
    [J]. CARDIOVASCULAR RESEARCH, 1984, 18 (03) : 183 - 193
  • [3] MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION
    AXEL, L
    DOUGHERTY, L
    [J]. RADIOLOGY, 1989, 171 (03) : 841 - 845
  • [4] The combined effect of nonlinear filtration and window size on the accuracy of tissue displacement estimation using detected echo signals
    Behar, V
    Adam, D
    Lysyansky, P
    Friedman, Z
    [J]. ULTRASONICS, 2004, 41 (09) : 743 - 753
  • [5] Alterations in the determinants of diastolic suction during pacing tachycardia
    Bell, SP
    Nyland, L
    Tischler, MD
    McNabb, M
    Granzier, H
    LeWinter, MM
    [J]. CIRCULATION RESEARCH, 2000, 87 (03) : 235 - 240
  • [6] STATISTICS NOTES .12. CALCULATING CORRELATION-COEFFICIENTS WITH REPEATED OBSERVATIONS .1. CORRELATION WITHIN-SUBJECTS
    BLAND, JM
    ALTMAN, DG
    [J]. BRITISH MEDICAL JOURNAL, 1995, 310 (6977) : 446 - 446
  • [7] A NOVEL METHOD FOR ANGLE INDEPENDENT ULTRASONIC-IMAGING OF BLOOD-FLOW AND TISSUE MOTION
    BOHS, LN
    TRAHEY, GE
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) : 280 - 286
  • [8] Speckle tracking for multi-dimensional flow estimation
    Bohs, LN
    Geiman, BJ
    Anderson, ME
    Gebhart, SC
    Trahey, GE
    [J]. ULTRASONICS, 2000, 38 (1-8) : 369 - 375
  • [9] ROTATIONAL DEFORMATION OF THE CANINE LEFT-VENTRICLE MEASURED BY MAGNETIC-RESONANCE TAGGING - EFFECTS OF CATECHOLAMINES, ISCHEMIA, AND PACING
    BUCHALTER, MB
    RADEMAKERS, FE
    WEISS, JL
    ROGERS, WJ
    WEISFELDT, ML
    SHAPIRO, EP
    [J]. CARDIOVASCULAR RESEARCH, 1994, 28 (05) : 629 - 635
  • [10] Left ventricular form and function - Scientific priorities and strategic planning for development of new views of disease
    Buckberg, GD
    Weisfeldt, ML
    Ballester, M
    Beyar, R
    Burkhoff, D
    Coghlan, HC
    Doyle, M
    Epstein, ND
    Gharib, M
    Ideker, RE
    Ingels, NB
    LeWinter, MM
    McCulloch, AD
    Pohost, GM
    Reinlib, LJ
    Sahn, DJ
    Sopko, G
    Spinale, FG
    Spotnitz, HM
    Torrent-Guasp, F
    Shapiro, EP
    [J]. CIRCULATION, 2004, 110 (14) : E333 - E336