Endoscopic laser imaging of tissue perfusion: New instrumentation and technique

被引:20
作者
Forrester, KR
Stewart, C
Leonard, C
Tulip, J
Bray, RC
机构
[1] Univ Calgary, McCaig Ctr Joint Injury & Arthrit Res, Dept Surg, Calgary, AB T2N 4N1, Canada
[2] Univ Calgary, Dept Med Sci, Calgary, AB T2N 4N1, Canada
[3] Univ Alberta, Elect & Comp Engn Res Facil, Edmonton, AB T6G 2V4, Canada
关键词
endoscope; blood flow; laser speckle; laser Doppler; joint tissue;
D O I
10.1002/lsm.10207
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives: New instrumentation, based on a previously established laser speckle perfusion imaging (LSI) technique is evaluated for its ability to capture and generate blood flow images during endoscopic surgery. Study Design/Materials and Methods: Investigations are detailed in an in-vitro blood flow model simulating physiological properties of vascularized tissue, and in-vivo in rabbit joint capsule tissue. Results: In-vitro measurements showed a linear response of the instrument to blood flow in the range of 0-800 mul/minute, where data points were significantly correlated with an r(2) value of 0.96. In-vivo measurements showed a 58.7% decrease to the medial collateral ligament during occlusion of the femoral artery. Conclusions: Blood flow images demonstrate that the endoscopic LSI technique is capable of measuring relative tissue blood flow changes at high resolutions and rapid response times and incorporates well with endoscopic surgeries. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 22 条
[1]   Vascular response of the meniscus to injury: effects of immobilization [J].
Bray, RC ;
Smith, JA ;
Eng, MK ;
Leonard, CA ;
Sutherland, CA ;
Salo, PT .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (03) :384-390
[2]  
Bray RC, 1996, J ANAT, V188, P87
[3]   Laser Doppler and time-varying speckle: A reconciliation [J].
Briers, JD .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (02) :345-350
[4]   Capillary blood flow monitoring using laser speckle contrast analysis (LASCA) [J].
Briers, JD ;
Richards, G ;
He, XW .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) :164-175
[5]  
Challoner AVJ, 1979, NONINVASIVE PHYSL ME, V1, P125
[6]  
CLOUGH G, 1997, ACI INT, V9, P41
[7]  
ENGLEHART M, 1983, J INVEST DERMATOL, V80, P12
[8]  
Ennos A.E., 1984, LASER SPECKLE RELATE
[9]   A LASER DOPPLER SCANNER FOR IMAGING BLOOD-FLOW IN SKIN [J].
ESSEX, TJH ;
BYRNE, PO .
JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (03) :189-194
[10]  
Felson DT, 1998, ARTHRITIS RHEUM, V41, P1343, DOI 10.1002/1529-0131(199808)41:8<1343::AID-ART3>3.0.CO