Dual focal-spot imaging for phase extraction in phase-contrast radiography

被引:27
作者
Donnelly, EF [1 ]
Price, RR [1 ]
Pickens, DR [1 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
关键词
D O I
10.1118/1.1598672
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate dual focal spot imaging as a method for extracting the phase component from a phase-contrast radiography image. All measurements were performed using a microfocus tungsten-target x-ray tube with an adjustable focal-spot size (0.01 mm to 0.045 mm). For each object, high-resolution digital radiographs were obtained with two different focal spot sizes to produce matched image pairs in which all other geometric variables as well as total exposure and tube kVp were held constant. For each image pair, a phase extraction was performed using pixel-wise division. The phase-extracted image resulted in an image similar to the standard image processing tool commonly referred to as "unsharp masking" but with the additional edge-enhancement produced by phase-contrast effects. The phase-extracted image illustrates the differences between the two images whose imaging parameters differ only in focal spot size. The resulting image shows effects from both phase contrast as well as geometric unsharpness. In weakly attenuating materials the phase-contrast effect predominates, while in strongly attenuating materials the phase effects are so small that they are not detectable. The phase-extracted image in the strongly attenuating object reflects differences in geometric unsharpness. The degree of phase extraction depends strongly on the size of the smallest focal spot used. This technique of dual-focal spot phase-contrast radiography provides a simple technique for phase-component (edge) extraction in phase-contrast radiography. In strongly attenuating materials the phase-component is overwhelmed by differences in geometric unsharpness. In these cases the technique provides a form of unsharp masking which also accentuates the edges. Thus, the two effects are complimentary and may be useful in the detection of small objects. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:2292 / 2296
页数:5
相关论文
共 6 条
[1]   X-RAY IMAGE-CONTRAST FROM A SIMPLE PHASE OBJECT [J].
DAVIS, TJ ;
GUREYEV, TE ;
GAO, D ;
STEVENSON, AW ;
WILKINS, SW .
PHYSICAL REVIEW LETTERS, 1995, 74 (16) :3173-3176
[2]   Quantification of the effect of kVp on edge-enhancement index in phase-contrast radiography [J].
Donnelly, EF ;
Price, RR .
MEDICAL PHYSICS, 2002, 29 (06) :999-1002
[3]   X-RAY INTERACTIONS - PHOTOABSORPTION, SCATTERING, TRANSMISSION, AND REFLECTION AT E=50-30,000 EV, Z=1-92 [J].
HENKE, BL ;
GULLIKSON, EM ;
DAVIS, JC .
ATOMIC DATA AND NUCLEAR DATA TABLES, 1993, 54 (02) :181-342
[4]   Phase contrast enhancement of x-ray mammography: a design study [J].
Kotre, CJ ;
Birch, IP .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2853-2866
[5]   Contrast and resolution in imaging with a microfocus x-ray source [J].
Pogany, A ;
Gao, D ;
Wilkins, SW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07) :2774-2782
[6]   Phase-contrast imaging using polychromatic hard X-rays [J].
Wilkins, SW ;
Gureyev, TE ;
Gao, D ;
Pogany, A ;
Stevenson, AW .
NATURE, 1996, 384 (6607) :335-338