The problem with composite end points in cardiovascular studies - The story of major adverse cardiac events and percutaneous coronary intervention

被引:243
作者
Kip, Kevin E. [1 ]
Hollabaugh, Kim [2 ]
Marroquin, Oscar C. [3 ]
Williams, David O. [4 ]
机构
[1] Univ S Florida, Coll Nursing, Tampa, FL 33612 USA
[2] Univ Pittsburgh, Sch Nursing, Pittsburgh, PA 15261 USA
[3] Univ Pittsburgh, Cardiovasc Inst, Pittsburgh, PA USA
[4] Rhode Isl Hosp, Dept Cardiol, Providence, RI USA
关键词
D O I
10.1016/j.jacc.2007.10.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Our purpose was to evaluate the heterogeneity and validity of composite end points, major adverse cardiac events (MACE) in particular, in cardiology research. Background The term MACE is a commonly used end point for cardiovascular research. By definition, MACE is a composite of clinical events and usually includes end points reflecting safety and effectiveness. There is no standard definition for MACE, as individual outcomes used to make this composite end point vary by study. This inconsistency calls into question whether use of MACE in cardiology research is of value. Methods We conducted a 2-phase literature review on the use of MACE as a composite end point: 1) studies that have compared use of bare-metal versus drug-eluting stents; and 2) studies published in the Journal in calendar year 2006. We subsequently tested 3 different definitions of MACE during 1-year of follow-up among 6,922 patients in the DEScover registry who received at least I drug-eluting stent. Results The review identified substantial heterogeneity in the study-specific individual outcomes used to define MACE. Markedly different results were observed for selected patient subsets of acute myocardial infarction (Ml) (vs. no MI) and multilesion stenting (vs. single-lesion stenting) according to the various definitions of MACE. Conclusions Varying definitions of composite end points, such as MACE, can lead to substantially different results and conclusions. Therefore, the term MACE, in particular, should not be used, and when composite study end points are desired, researchers should focus separately on safety and effectiveness outcomes, and construct separate composite end points to match these different clinical goals.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 59 条
[1]   A randomized comparison of sirolimus-eluting stent with balloon angioplasty in patients with in-stent restenosis -: Results of the restenosis intrastent:: Balloon angioplasty versus elective sirolimus-eluting stenting (RIBS-II) trial [J].
Alfonso, Fernando ;
Perez-Vizcayno, Maria-Jose ;
Hernandez, Rosana ;
Bethencourt, Armando ;
Marti, Vicens ;
Lopez-Minguez, Jose R. ;
Angel, Juan ;
Mantilla, Ramon ;
Moris, Cesar ;
Cequier, Angel ;
Sabate, Manel ;
Escaned, Javier ;
Moreno, Raul ;
Bañuelos, Camino ;
Suarez, Alfonso ;
Macaya, Carlos .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (11) :2152-2160
[2]   Rheolytic thrombectomy with percutaneous coronary intervention for infarct size reduction in acute myocardial infarction - 30-day results from a multicenter randomized study [J].
Ali, Arshad ;
Cox, David ;
Dib, Nabil ;
Brodie, Bruce ;
Berman, Daniel ;
Gupta, Navin ;
Browne, Kevin ;
Iwaoka, Robert ;
Azrin, Michael ;
Stapleton, Dwight ;
Setum, Cindy ;
Popma, Jeffrey .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (02) :244-252
[3]   Sirolimus-eluting vs uncoated stents for prevention of restenosis in small coronary arteries - A randomized trial [J].
Ardissino, D ;
Cavallini, C ;
Bramucci, E ;
Indolfi, C ;
Marzocchi, A ;
Manari, A ;
Angeloni, G ;
Carosio, G ;
Bonizzoni, E ;
Colusso, S ;
Repetto, M ;
Merlini, PA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 292 (22) :2727-2734
[4]   A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents [J].
Babapulle, MN ;
Joseph, L ;
Bélisle, P ;
Brophy, JM ;
Eisenberg, MJ .
LANCET, 2004, 364 (9434) :583-591
[5]   What is the risk of stent thrombosis associated with the use of paclitaxel-eluting stents for percutaneous coronary intervention? A meta-analysis [J].
Bavry, AA ;
Kumbhani, DJ ;
Helton, TJ ;
Bhatt, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (06) :941-946
[6]   Remote-control percutaneous coronary interventions - Concept, validation, and first-in-humans pilot clinical trial [J].
Beyar, R ;
Gruberg, L ;
Deleanu, D ;
Roguin, A ;
Almagor, Y ;
Cohen, S ;
Kumar, G ;
Wenderow, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (02) :296-300
[7]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[8]   Drug-eluting stent restenosis - The pattern predicts the outcome [J].
Cosgrave, John ;
Melzi, Gloria ;
Biondi-Zoccai, Giuseppe G. L. ;
Airoldi, Flavio ;
Chieffo, Alaide ;
Sangiorgi, Giuseppe M. ;
Montorfano, Matteo ;
Michev, Iassen ;
Carlino, Mauro ;
Bonizzoni, Erminio ;
Colombo, Antonio .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (12) :2399-2404
[9]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[10]   Cost analysis from two randomized trials of sirolimus-eluting stents versus paclitaxel-eluting stents in high-risk patients with coronary artery disease [J].
Elezi, Shpend ;
Dibra, Alban ;
Folkerts, Ulrike ;
Mehilli, Julinda ;
Heigl, Sylvia ;
Schoemig, Albert ;
Kastrati, Adrian .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (02) :262-267