Non-axisymmetric reflectors concentrating radiation from an asymmetric heliostat field onto a circular absorber

被引:7
作者
Spirkl, W
Timinger, A
Ries, H
Kribus, A
Muschaweck, J
机构
[1] Ludwigs Maximillian Univ, Sekt Phys, D-80799 Munich, Germany
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[3] Weizmann Inst Sci, Environm Sci & Energy Res Dept, IL-76100 Rehovot, Israel
关键词
D O I
10.1016/S0038-092X(98)00037-1
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In solar tower plants, where a rotationally symmetric field of heliostats surrounds the tower, an axisymmetric secondary concentrator such as a compound parabolic concentrator (CPC)ora tailored concentrator or a cone is the obvious choice. For locations at higher latitudes, however, the reflecting; area of the heliostats may be used more efficiently if the field of heliostats is located opposite to the sun as seen from the tower. Then the field is asymmetric with regard to the tower. In the case of an asymmetric field, an axisymmetric concentrator necessarily has a concentration significantly lower than the upper limit. Furthermore, the area on the ground from which a tilted axisymmetric concentrator accepts radiation is an ellipse, including also heliostats very distant to the tower producing a large image of the sun. For these reasons we investigate asymmetric secondaries. From the shape of the edge ray reflectors constructed for rays in the central south-north plane we conclude that a skew cone reflector might be appropriate for the field, and optimize its free parameters by means of ray tracing. Asymmetric concentrators may increase the concentration by up to 25% at the same efficiency compared to optimized axisymmetric CPC or cone reflectors. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 1992, SMR
[2]   ANALYSIS OF THE TERMINAL CONCENTRATOR CONCEPT FOR SOLAR CENTRAL RECEIVER SYSTEMS [J].
ATHAVALEY, K ;
LIPPS, F ;
VANTHULL, L .
SOLAR ENERGY, 1979, 22 (06) :493-504
[3]  
DORON P, 1996, 8 INT S SOL THERM CO
[4]   NEW HIGH-FLUX 2-STAGE OPTICAL DESIGNS FOR PARABOLIC SOLAR CONCENTRATORS [J].
FRIEDMAN, RP ;
GORDON, JM ;
RIES, H .
SOLAR ENERGY, 1993, 51 (05) :317-325
[5]  
FRIEDMAN RP, 1995, P ISES SOL WORLD C S
[6]   AN ANALYSIS FOR SOLAR CENTRAL RECEIVER SYSTEMS WITH TERMINAL CONCENTRATORS OR VARIABLE APERTURES [J].
GALAL, T ;
NARDIN, P ;
MIGNOT, J .
SOLAR ENERGY, 1988, 41 (02) :147-157
[7]   TAILORED EDGE-RAY CONCENTRATORS AS IDEAL 2ND STAGES FOR FRESNEL REFLECTORS [J].
GORDON, JM ;
RIES, H .
APPLIED OPTICS, 1993, 32 (13) :2243-2251
[8]  
KARNI J, 1994, P 7 INT S SOL THER C, V4, P796
[9]  
KARNI J, 1997, UNPUB J SOL ENERGY E
[10]   TAILORED EDGE-RAY DESIGNS FOR UNIFORM ILLUMINATION OF DISTANT TARGETS [J].
ONG, PT ;
GORDON, JM ;
RABL, A ;
CAI, W .
OPTICAL ENGINEERING, 1995, 34 (06) :1726-1737