In-situ monitoring of damage in CFRP laminates by means of AC and DC measurements

被引:191
作者
Abry, JC
Choi, YK
Chateauminois, A
Dalloz, B
Giraud, G
Salvia, M
机构
[1] Ecole Cent Lyon, CNRS, UMR 5621, Lab Ingn Fonctionnalisat Surfaces, F-69131 Ecully, France
[2] Univ Aix Marseille 1, CNRS, UMR 139, Lab Phys Syst Desordonnes, F-13331 Marseille 3, France
关键词
health monitoring; carbon-fibre-reinforced polymers; composite materials; electrical resistance; capacitance;
D O I
10.1016/S0266-3538(00)00181-0
中图分类号
TB33 [复合材料];
学科分类号
摘要
Periodical maintenance NDT-based inspections are generally used for almost all complex technological structures today. The idea of using specific sensors integrated in the structure for structural real time monitoring (or health monitoring) is now in progress. Carbon-fibre-reinforced polymers (CFRP) are increasingly used as structural parts, especially in the aircraft industry. This work deals with the possibility of detecting in-situ damage in CFRP by the use of DC or AC electrical property measurements. Monotonic tests under post-buckling bending conditions are being performed on cross ply [0/90](s) and [90/0](s) carbon/epoxy laminates. The monitoring of electrical resistance and capacitance changes, linked to the modifications of the conduction paths in the composite, and occurrence of voids during loading, allowed the detection of damage growth. It seems that DC electrical conduction allows to detect fibre failure, but AC measurements are more suitable for monitoring matrix cracks (delamination, fibre/matrix debonding or transverse cracks). (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:855 / 864
页数:10
相关论文
共 10 条
  • [1] In situ detection of damage in CFRP laminates by electrical resistance measurements
    Abry, JC
    Bochard, S
    Chateauminois, A
    Salvia, M
    Giraud, G
    [J]. COMPOSITES SCIENCE AND TECHNOLOGY, 1999, 59 (06) : 925 - 935
  • [2] Abry JC, 1999, SMART MATERIALS AND STRUCTURES, P389
  • [3] Damage mechanisms characterisation of carbon fibre/epoxy composite laminates by both electrical resistance measurements and acoustic emission analysis
    Ceysson, O
    Salvia, M
    Vincent, L
    [J]. SCRIPTA MATERIALIA, 1996, 34 (08) : 1273 - 1280
  • [4] Use of Insitu dielectric sensing for intelligent processing and health monitoring
    Kranbuehl, D
    Aandahl, H
    Haralampus, N
    Newby, W
    Hood, D
    Boiteux, G
    Seytre, G
    Pascault, P
    Maazouz, A
    Gerard, JF
    Sautereau, H
    Chailan, JF
    Loos, AC
    MacRae, JD
    [J]. THIRD INTERNATIONAL CONFERENCE ON INTELLIGENT MATERIALS - THIRD EUROPEAN CONFERENCE ON SMART STRUCTURES AND MATERIALS, 1996, 2779 : 112 - 117
  • [5] Large-Toumi B, 1996, ASTM INT, V1290, P182
  • [6] Muto N., 1994, Sensors and Materials, V6, P45
  • [7] LOAD AND FAILURE ANALYSES OF CFRP LAMINATES BY MEANS OF ELECTRICAL-RESISTIVITY MEASUREMENTS
    SCHULTE, K
    BARON, C
    [J]. COMPOSITES SCIENCE AND TECHNOLOGY, 1989, 36 (01) : 63 - 76
  • [8] SCHULTE K, 1995, 10 INT C COMP MAT, V5, P315
  • [9] THIAGARAJAN C, 1994, P 2 EUR C SMART STRU, P128
  • [10] Sensing damage in carbon fiber polymer-matrix composites during fatigue by electrical resistance measurement
    Wang, XJ
    Chung, DDL
    [J]. SMART STRUCTURES AND MATERIALS 1998: SENSORY PHENOMENA AND MEASUREMENT INSTRUMENTATION FOR SMART STRUCTURES AND MATERIALS, 1998, 3330 : 36 - 47