Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters

被引:401
作者
Wu, Heng [1 ]
Wang, Xiongfei [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Grid faults; phase-locked loop (PLL); transient stability; voltage-source converters (VSCs); INSTABILITY; REDUCTION; SYSTEM;
D O I
10.1109/TPEL.2019.2937942
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
080906 [电磁信息功能材料与结构]; 082806 [农业信息与电气工程];
摘要
Differing from synchronous generators, there are lack of physical laws governing the synchronization dynamics of voltage-source converters (VSCs). The widely used phase-locked loop (PLL) plays a critical role in maintaining the synchronism of current-controlled VSCs, whose dynamics are highly affected by the power exchange between VSCs and the grid. This article presents a design-oriented analysis on the transient stability of PLL-synchronized VSCs, i.e., the synchronization stability of VSCs under large disturbances, by employing the phase portrait approach. Insights into the stabilizing effects of the first- and second-order PLLs are provided with the quantitative analysis. It is revealed that simply increasing the damping ratio of the second-order PLL may fail to stabilize VSCs during severe grid faults, whereas the first-order PLL can always guarantee the transient stability of VSCs when equilibrium operation points exist. An adaptive PLL that switches between the second-order and the first-order PLL during the fault-occurring-clearing transient is proposed for preserving both the transient stability and the phase-tracking accuracy. Time-domain simulations and experimental tests, considering both the grid fault and the fault recovery, are performed, and the obtained results validate the theoretical findings.
引用
收藏
页码:3573 / 3589
页数:17
相关论文
共 38 条
[1]
[Anonymous], [No title captured]
[2]
[Anonymous], POWER SYSTEM STABILI
[3]
[Anonymous], 2014, Nonlinear Dynamics and Chaos: With Applications to Physics, Biology, Chemistry, and Engineering
[4]
[Anonymous], 2008, GEN PLANTS CONN MED
[5]
[Anonymous], [No title captured]
[6]
[Anonymous], 2000, CONTROL SYSTEM DESIG
[7]
[Anonymous], Frequency Measurement Requirements and Usage: Final Version 7
[8]
Fault analysis on distribution feeders with distributed generators [J].
Baran, ME ;
El-Markaby, I .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (04) :1757-1764
[9]
Distributed Power-Generation Systems and Protection [J].
Blaabjerg, Frede ;
Yang, Yongheng ;
Yang, Dongsheng ;
Wang, Xiongfei .
PROCEEDINGS OF THE IEEE, 2017, 105 (07) :1311-1331