Complications related to less-invasive haemodynamic monitoring

被引:66
作者
Belda, F. J. [1 ]
Aguilar, G. [1 ]
Teboul, J. L. [2 ]
Pestana, D. [3 ]
Redondo, F. J. [4 ]
Malbrain, M. [5 ]
Luis, J. C. [6 ]
Ramasco, F. [7 ]
Umgelter, A. [8 ]
Wendon, J. [9 ]
Kirov, M. [10 ]
Fernandez-Mondejar, E. [11 ]
机构
[1] Hosp Clin Univ Valencia, Anesthesiol & Intens Care Dept, Valencia, Spain
[2] Ctr Hosp Biocetre, Serv Reanimat Med, Paris, France
[3] Hosp Univ La Paz, Anesthesiol & Intens Care Dept, Madrid, Spain
[4] Hosp Gen Ciudad Real, Anesthesiol & Intens Care Dept, Ciudad Real, Spain
[5] ZiekenhuisNetwerk Antwerpen, Dept Intens Care, Antwerp, Belgium
[6] Hosp Univ Virgen del Rocio, Anesthesiol & Intens Care Dept, Seville, Spain
[7] Univ Hosp La Princesa, Anesthesiol & Intens Care Dept, Madrid, Spain
[8] Tech Univ Munich, Klinikum Rechts Isar, Med Klin & Poliklin 2, D-8000 Munich, Germany
[9] Kings Coll Hosp London, Inst Liver Studies, London SE5 8RX, England
[10] No State Med Univ, Anesthesiol & Intens Care Dept, Arkhangelsk, Russia
[11] Hosp Univ Virgen de las Nieves, Dept Intens Care, Granada, Spain
关键词
arteries; cannulation; complications; monitoring; cardiopulmonary; CATHETER; MANAGEMENT;
D O I
10.1093/bja/aeq377
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Background. The aim of this study was to evaluate the type and incidence of complications during insertion, maintenance, and withdrawal of central arterial catheters used for transpulmonary thermodilution haemodynamic monitoring (PiCCO (TM)). Methods. We conducted a prospective, observational, multicentre study in 14 European intensive care units (six countries). A total of 514 consecutive patients in whom haemodynamic monitoring by PiCCO (TM) was indicated were studied. Results. Five hundred and fourteen PiCCO catheters (475 in femoral, 26 in radial, nine in axillary, and four in brachial arteries) were inserted. Arterial access was obtained on the first attempt in 86.4% of the patients. Minor problems such as oozing after insertion (3.3%) or removal of the catheter (3.5%) were observed, but no episodes of serious bleeding (more than 50 ml) were recorded. Small local haematomas were observed after insertion (4.5%) and after removal (1.2%) of the catheter. These complications were not more frequent in patients with coagulation abnormalities. The incidence of site inflammation and catheter-related infection was 2% and 0.78%, respectively. Other complications such as ischaemia (0.4%), pulse loss (0.4%), or femoral artery thrombosis (0.2%) were rare, transient, and all resolved with catheter removal or embolectomy, respectively. Conclusions. In this series of patients, central arterial catheters used for PiCCO (TM) monitoring were demonstrated to be a safe alternative for advanced haemodynamic monitoring.
引用
收藏
页码:482 / 486
页数:5
相关论文
共 24 条
[1]
Abreu Alexandre R, 2004, J Intensive Care Med, V19, P291, DOI 10.1177/0885066604265255
[2]
Radial to femoral arterial blood pressure differences during liver transplantation [J].
Arnal, D ;
Garutti, I ;
Perez-Peña, J ;
Olmedilla, L ;
Tzenkov, IG .
ANAESTHESIA, 2005, 60 (08) :766-771
[3]
BARASH PG, 1981, J THORAC CARDIOV SUR, V82, P5
[4]
BELDA FJ, 2007, YB INTENSIVE CARE 20, P501
[5]
PULMONARY COMPLICATIONS OF FLOW-DIRECTED BALLOON-TIPPED CATHETER [J].
FOOTE, GA ;
SCHABEL, SI ;
HODGES, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1974, 290 (17) :927-931
[6]
Frezza EE, 1998, AM SURGEON, V64, P127
[7]
Galluccio ST, 2009, CRIT CARE RESUSC, V11, P34
[8]
Can femoral artery pressure monitoring be used routinely in cardiac surgery? [J].
Haddad, Fadia ;
Zeeni, Carine ;
El Rassi, Issam ;
Yazigi, Alexandre ;
Madi-Jebara, Samia ;
Hayeck, Gemma ;
Jebara, Victor ;
Yazbeck, Patricia .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (03) :418-422
[9]
Evidence-based review of the use of the pulmonary artery catheter: impact data and complications [J].
Hadian, Mehrnaz ;
Pinsky, Michael R. .
CRITICAL CARE, 2006, 10 (Suppl 3)
[10]
Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial [J].
Harvey, S ;
Harrison, DA ;
Singer, M ;
Ashcroft, J ;
Jones, CM ;
Elbourne, D ;
Brampton, W ;
Williams, D ;
Young, D ;
Rowan, K .
LANCET, 2005, 366 (9484) :472-477