Trabecular bone volume fraction mapping by low-resolution MRI

被引:36
作者
Fernández-Seara, MA [1 ]
Song, HK [1 ]
Wehrli, FW [1 ]
机构
[1] Univ Penn, Med Ctr, Dept Radiol, Lab Struct NMR Imaging, Philadelphia, PA 19104 USA
关键词
bone volume measurement; B-1; correction; fast spin echo; calcaneus;
D O I
10.1002/mrm.1165
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Trabecular bone volume fraction (TBVF) is highly associated with the mechanical competence of trabecular bone. TBVF is ordinarily measured by histomorphometry from bone biopsies or, noninvasively, by means of high-resolution microcomputed tomography and, more recently, by micro-MRI. The latter methods require spatial resolution sufficient to resolve trabeculae, along with segmentation techniques that allow unambiguous assignment of the signal to bone or bone marrow. In this article it is shown that TBVF can be measured under low-resolution conditions by exploiting the attenuation of the MR signal resulting from fractional occupancy of the imaging voxel by bone and bone marrow, provided that a reference signal is available from a marrow volume devoid of trabeculation. The method requires accurate measurement of apparent proton density, which entails correction for various sources of error. Key among these are the spatial nonuniformity in the RF field amplitude and effects of the slice profile, which are determined by B, field mapping and numerical integration of the Bloch equations, respectively. By contrast, errors from variations in bone marrow composition (hematopoietic vs. fatty) between trabecular and reference site are predicted to be small and usually negligible. The method was evaluated in phantoms and in vivo in the distal radius and found to be accurate to 1% in marrow volume fraction. Finally, in a group of 12 patients of varying skeletal status, TBVF in the calcaneus was found to strongly correlate with integral bone mineral density of the lumbar vertebrae (r(2) = 0.83, p < 0.0001). The method may fail in large imaging objects such as the human trunk at high magnetic field where standing wave and RF penetration effects cause intensity variations that cannot be corrected. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:103 / 113
页数:11
相关论文
共 44 条
  • [1] RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING
    BOTTOMLEY, PA
    ANDREW, ER
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) : 630 - 643
  • [2] RELATIONSHIP BETWEEN NMR TRANSVERSE RELAXATION, TRABECULAR BONE ARCHITECTURE, AND STRENGTH
    CHUNG, H
    WEHRLI, FW
    WILLIAMS, JL
    KUGELMASS, SD
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (21) : 10250 - 10254
  • [3] EPIDEMIOLOGY OF OSTEOPOROSIS AND OSTEOPOROTIC FRACTURES
    CUMMINGS, SR
    KELSEY, JL
    NEVITT, MC
    ODOWD, KJ
    [J]. EPIDEMIOLOGIC REVIEWS, 1985, 7 : 178 - 208
  • [4] APPENDICULAR BONE-DENSITY AND AGE PREDICT HIP FRACTURE IN WOMEN
    CUMMINGS, SR
    BLACK, DM
    NEVITT, MC
    BROWNER, WS
    CAULEY, JA
    GENANT, HK
    MASCIOLI, SR
    SCOTT, JC
    SEELEY, DG
    STEIGER, P
    VOGT, TM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (05): : 665 - 668
  • [5] Custer R.P., 1974, An atlas of the blood and bone marrow
  • [6] Fautz HP, 2000, MAGNET RESON MED, V43, P577, DOI 10.1002/(SICI)1522-2594(200004)43:4<577::AID-MRM12>3.0.CO
  • [7] 2-D
  • [8] COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING
    GLOVER, GH
    HAYES, CE
    PELC, NJ
    EDELSTEIN, WA
    MUELLER, OM
    HART, HR
    HARDY, CJ
    ODONNELL, M
    BARBER, WD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) : 255 - 270
  • [9] Quantitative ultrasound techniques for the assessment of osteoporosis: Expert agreement on current status
    Gluer, CC
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (08) : 1280 - 1288
  • [10] THE RELATIONSHIP BETWEEN THE STRUCTURAL AND ORTHOGONAL COMPRESSIVE PROPERTIES OF TRABECULAR BONE
    GOULET, RW
    GOLDSTEIN, SA
    CIARELLI, MJ
    KUHN, JL
    BROWN, MB
    FELDKAMP, LA
    [J]. JOURNAL OF BIOMECHANICS, 1994, 27 (04) : 375 - 389