Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system

被引:101
作者
Rotter, M
Takahashi, Y
Sanders, P [1 ]
Haïssaguerre, M
Jaïs, P
Hsu, LF
Sacher, F
Pasquié, JL
Clementy, J
Hocini, M
机构
[1] Hop Cardiol, Bordeaux, France
[2] Univ Victor Segalen Bordeaux 2, Bordeaux, France
关键词
atrial fibrillation; pulmonary vein isolation; linear ablation; non-fluoroscopic imaging;
D O I
10.1093/eurheartj/ehi172
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Catheter ablation of atrial. fibrillation (AF) is centred on pulmonary vein (PV) ablation with or without additional atrial. substrate modification. These procedures may be prolonged with significant fluoroscopy exposure. This study evaluates a new non-fluoroscopic navigation system during ablation of AF. Methods and results Seventy-two patients undergoing catheter ablation of symptomatic drug refractory AF were prospectively randomized to ablation with (n = 35; study group) or without (n = 37; control group) non-fluoroscopic navigation. PV isolation was performed in all patients. In patients with persistent or inducible sustained AF after PV isolation linear ablation was performed by joining the superior PVs. PV isolation was achieved in all patients; fluoroscopy (15.4 +/- 3.4 vs. 21.3 +/- 6.4 min; P < 0.001) and procedural (52 +/- 12 vs. 61 +/- 17 min; P = 0.02) durations were significantly reduced in the study group. Linear block was achieved in 37 of the 39 patients; with a significant reduction in fluoroscopy (5.6 +/- 2.2 vs. 9.9 +/- 4.8 min; P = 0.003) and procedural (14.7 +/- 5.5 vs. 26.6 +/- 16.9 min; P = 0.007) durations in the study group. After a follow-up of 6.9 +/- 2.9 months (range 3-10), 26 (74%) patients in the non-fluoroscopic navigation group and 29 (78%) patients in the control group were arrhythmia-free after the first procedure. Conclusion This prospectively randomized study demonstrates significant reduction of fluoroscopy exposure and procedural duration using supplementary non-fluoroscopic imaging system for AF ablation.
引用
收藏
页码:1415 / 1421
页数:7
相关论文
共 19 条
[1]   Feasibility and safety of pulmonary vein isolation using a new mapping and navigation system in patients with refractory atrial fibrillation [J].
Arentz, T ;
von Rosenthal, J ;
Blum, T ;
Stockinger, J ;
Bürkle, G ;
Weber, R ;
Jander, N ;
Neumann, FJ ;
Kalusche, D .
CIRCULATION, 2003, 108 (20) :2484-2490
[2]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[3]   Multiple atrial macro-re-entry circuits in adults with repaired congenital heart disease: Entrainment mapping combined with three-dimensional electroanatomic mapping [J].
Delacretaz, E ;
Ganz, LI ;
Soejima, K ;
Friedman, PL ;
Walsh, EP ;
Triedman, JK ;
Sloss, LJ ;
Landzberg, MJ ;
Stevenson, WG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (06) :1665-1676
[4]  
Ernst S, 2003, J AM COLL CARDIOL, V42, P1271, DOI 10.1016/S0735-1097(03)00940-9
[5]   Changes in atrial fibrillation cycle length and inducibility during catheter ablation and their relation to outcome [J].
Haïssaguerre, M ;
Sanders, P ;
Hocini, M ;
Hsu, LF ;
Shah, DC ;
Scavée, C ;
Takahashi, Y ;
Rotter, M ;
Pasquié, JL ;
Garrigue, S ;
Clémenty, J ;
Jaïs, P .
CIRCULATION, 2004, 109 (24) :3007-3013
[6]   Electrophysiological breakthroughs from the left atrium to the pulmonary veins [J].
Haïssaguerre, M ;
Shah, DC ;
Jaïs, P ;
Hocini, M ;
Yamane, T ;
Deisenhofer, I ;
Chauvin, M ;
Garrigue, S ;
Clémenty, J .
CIRCULATION, 2000, 102 (20) :2463-2465
[7]   A focal source of atrial fibrillation treated by discrete radiofrequency ablation [J].
Jais, P ;
Haissaguerre, M ;
Shah, DC ;
Chouairi, S ;
Gencel, L ;
Hocini, M ;
Clementy, J .
CIRCULATION, 1997, 95 (03) :572-576
[8]   Technique and results of linear ablation at the mitral isthmus [J].
Jaïs, P ;
Hocini, M ;
Hsu, LF ;
Sanders, P ;
Scavee, C ;
Weerasooriya, R ;
Macle, L ;
Raybaud, F ;
Garrigue, S ;
Shah, DC ;
Le Metayer, P ;
Clémenty, J ;
Haïssaguerre, M .
CIRCULATION, 2004, 110 (19) :2996-3002
[9]   Pulmonary vein disconnection using the LocaLisa three-dimensional nonfluoroscopic catheter imaging system [J].
Macle, L ;
Jaïs, P ;
Scavée, C ;
Weerasooriya, R ;
Hocini, M ;
Shah, DC ;
Raybaud, F ;
Choi, KJ ;
Clémenty, J ;
Haïssaguerre, M .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (07) :693-697
[10]   Electrophysiological effects of long, linear atrial lesions placed under intracardiac ultrasound guidance [J].
Olgin, JE ;
Kalman, JM ;
Chin, M ;
Stillson, C ;
Maguire, M ;
Ursel, P ;
Lesh, MD .
CIRCULATION, 1997, 96 (08) :2715-2721