Test procedures for verification of an electron pencil beam algorithm implemented for treatment planning

被引:21
作者
Blomquist, M [1 ]
Karlsson, M [1 ]
Karlsson, M [1 ]
机构
[1] UMEA UNIV,DEPT RADIAT PHYS,S-90185 UMEA,SWEDEN
关键词
electron beams; algorithm verification; treatment planning; inhomogeneities;
D O I
10.1016/0167-8140(96)01742-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The calculation of an electron dose distribution in a patient is a difficult problem because of the presence of tissue and surface inhomogeneities. Verification of the dose planning system is therefore essential. In this investigation, a novel method is used to evaluate a commercially available system (Helax-TMS), at electron energies between 10 and 50 MeV, both for a conventional treatment unit and an MLC-collimated scanned beam unit with a helium-filled treatment head. First, the experiments were designed to verify the local beam database and some fundamental characteristics of the electron beam calculations. Secondly, a number of generalised situations that would be encountered in the clinical treatment planning were evaluated: oblique incidence, field shaping with multi-leaf collimator, bolus edges, and air cavities. Dose distributions in two generalised anatomical phantoms simulating a neck and a nose were also analysed. The results have, when so possible, been presented as the dose ratio within the 'flattened area' for dose profiles and down to the 'treatment depth' (80% dose level) for depth doses. In the penumbra region and in the dose fall-off region, the comparison has been represented by the distance deviation between calculated and measured dose profiles or depth doses. A new tool, 'volume integration', was used to evaluate the deviations from a more clinical point of view. Most results were within +/-2% in dose for volumes larger than a sphere with a diameter of 15 mm, or +/-2 mm in position. Dose deviations were generally found for oblique incidences and below heterogeneities such as small air cavities and bolus edges in limited volumes.
引用
收藏
页码:271 / 286
页数:16
相关论文
共 31 条
[1]  
AHNESJO A, COMMUNICATIONS
[2]   3D DOSE CALCULATIONS FOR ELECTRON AND PHOTON BEAMS [J].
ALTSCHULER, MD ;
BLOCH, P ;
BUHLE, EL ;
AYYALASOMAYAJULA, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (02) :391-411
[3]  
[Anonymous], 1993, 50 ICRU
[4]  
[Anonymous], 1978, 29 ICRU
[5]  
[Anonymous], 1984, 35 ICRU
[6]   ELECTRON DOSE DISTRIBUTIONS IN EXPERIMENTAL PHANTOMS - A COMPARISON WITH 2D PENCIL BEAM CALCULATIONS [J].
CYGLER, J ;
BATTISTA, JJ ;
SCRIMGER, JW ;
MAH, E ;
ANTOLAK, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) :1073-1086
[7]   THE PROBLEM OF OBLIQUELY INCIDENT BEAMS IN ELECTRON-BEAM TREATMENT PLANNING [J].
EKSTRAND, KE ;
DIXON, RL .
MEDICAL PHYSICS, 1982, 9 (02) :276-278
[8]   MULTIPLE SCATTERING WITH ENERGY LOSS [J].
EYGES, L .
PHYSICAL REVIEW, 1948, 74 (10) :1534-1535
[9]  
FRAASS BA, 1994, P 11 INT C US COMP R, P256
[10]   ELECTRON-BEAM DOSE CALCULATIONS [J].
HOGSTROM, KR ;
MILLS, MD ;
ALMOND, PR .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :445-459