A real-time NMR image reconstruction and display system was developed using a high-speed personal computer and optimized for the 32-bit multitasking Microsoft Windows 95 operating system. The system was operated at various CPU clock frequencies by changing the motherboard clock frequency and the processor/bus frequency ratio. When the Pentium CPU was used at the 200 MHz clock frequency, the reconstruction time for one 128 x 128 pixel image was 48 ms and that for the image display on the enlarged 256 x 256 pixel window was about 8 ms. NMR imaging experiments were performed with three fast imaging sequences (FLASH, multishot EPI, and one-shot EPI) to demonstrate the ability of the real-time system. It was concluded that in most cases, high-speed PC would be the best choice for the image reconstruction and display system for real-time MRI. (C) 1998 Academic Press.
引用
收藏
页码:138 / 141
页数:4
相关论文
共 10 条
[1]   REAL-TIME FUNCTIONAL MAGNETIC-RESONANCE-IMAGING [J].
COX, RW ;
JESMANOWICZ, A ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) :230-236
[2]   A real-time reconstruction system for magnetic resonance imaging [J].
Gmitro, AF ;
Ehsani, AR ;
Berchem, TA ;
Snell, RJ .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :734-740
[3]  
ICHIKAWA O, 1995, JPN J MAGN RESON MED, V15, P216
[4]   A REAL-TIME NMR IMAGE-RECONSTRUCTION SYSTEM USING ECHO-PLANAR IMAGING AND A DIGITAL SIGNAL PROCESSOR [J].
KOSE, K ;
INOUYE, T .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (12) :1161-1165
[5]   Real-time NMR imaging systems using personal computers [J].
Kose, K ;
Haishi, T ;
Caprihan, A ;
Fukushima, E .
JOURNAL OF MAGNETIC RESONANCE, 1997, 124 (01) :35-41
[6]  
KOSE K, 1996, JPN J MAGN RESON MED, V16, P98
[7]   FLUOROSCOPIC MR IMAGING AT 0.064 TESLA [J].
KRAMER, DM ;
HAWRYSZKO, C ;
ORTENDAHL, DA ;
MINAISE, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :358-361
[8]  
PAULY J, 1996, P ISMRM 4 ANN M, P395
[9]  
POTTER CS, 1994, P SMR 2 ANN M SAN FR, P835
[10]   REAL-TIME MR FLUOROSCOPIC DATA ACQUISITION AND IMAGE-RECONSTRUCTION [J].
WRIGHT, RC ;
RIEDERER, SJ ;
FARZANEH, F ;
ROSSMAN, PJ ;
LIU, Y .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) :407-415