Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative study

被引:57
作者
Bascarevic, Zoran [1 ]
Vukasinovic, Zoran [1 ]
Slavkovic, Nemanja [1 ]
Dulic, Borislav [2 ]
Trajkovic, Goran
Bascarevic, Violeta
Timotijevic, Sladjan [3 ]
机构
[1] Univ Belgrade, Fac Med, Inst Orthopaed Surg Banjica, Belgrade, Serbia
[2] Univ Belgrade, Fac Med, Clin Ctr Serbia, Inst Orthopaed Surg & Traumatol, Belgrade, Serbia
[3] Med Ctr Bezanijska Kosa, Dept Orthopaed, Belgrade, Serbia
关键词
FEMORAL-HEAD; WEAR; REPLACEMENT; COMPONENTS;
D O I
10.1007/s00264-009-0899-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The aim of the study was to evaluate the reliability and durability of alumina-on-alumina ceramic in comparison to metal-on-highly cross-linked polyethylene (CoCr/HXLPE) bearing couples. This prospective randomised study involved 150 patients (157 hips). All patients (mean age: 54.7 years) obtained an identical fibre metal midcoat femoral stem and fibre metal-coated acetabular shell. In 78 patients (82 hips) we used alumina, while in 72 patients (75 hips) metal-polyethylene bearing couples were used. During a mean 50.4-month follow-up period (51 +/- 8 alumina and 50 +/- 8.9 metal-polyethylene) no statistically significant changes in clinical and radiographic parameters were noted between the two groups. There was no ceramic breakage and no need for revision surgery due to the ceramic liner. The alumina bearing couples proved to be as reliable as CoCr/HXLPE.
引用
收藏
页码:1129 / 1135
页数:7
相关论文
共 24 条
[1]
Severe wear challenge to 36 mm mechanically enhanced highly crosslinked polyethylene hip liners [J].
Bowsher, J. G. ;
Williams, P. A. ;
Clarke, I. C. ;
Green, D. D. ;
Donaldson, T. K. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (01) :253-263
[2]
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[3]
Third-body wear of highly cross-linked polyethylene in a hip simulator [J].
Bragdon, CR ;
Jasty, M ;
Muratoglu, OK ;
O'Connor, DO ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2003, 18 (05) :553-561
[4]
Callaway GH, 1995, J ARTHROPLASTY, V10, P855
[5]
Ceramic-on-Ceramic Total Hip Arthroplasty: Update [J].
Capello, William N. ;
D'Antonio, James A. ;
Feinberg, Judy R. ;
Manley, Michael T. ;
Naughton, Marybetb .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :39-43
[6]
CLARKE IC, 1992, CLIN ORTHOP RELAT R, P19
[7]
New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Bierbaum, B .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :390-397
[8]
Modeling of bone around hydroxyapatite-coated femoral stems [J].
DAntonio, JA ;
Township, M ;
Capello, WN ;
Manley, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (08) :1226-1234
[9]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[10]
ENGH CA, 1990, CLIN ORTHOP RELAT R, P107