The role of magnetic resonance angiography for endoprosthetic design

被引:23
作者
Neschis, DG
Velazquez, OC
Baum, RA
Roberts, D
Carpenter, JP
Golden, MA
Mitchell, ME
Barker, CF
Pyeron, A
Fairman, RM
机构
[1] Hosp Univ Penn, Dept Surg, Philadelphia, PA 19104 USA
[2] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[3] Univ Maryland, Med Ctr, Div Vasc Surg, Baltimore, MD 21201 USA
关键词
D O I
10.1067/mva.2001.112211
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: Many patients with aortic aneurysms have renal insufficiency and may be at increased risk when conventional imaging modalities (contrast-enhanced computed tomography and arteriography) are used for aortic endograft design. Our objective was to determine if magnetic resonance angiography (MRA) could be used as the sole imaging modality for endoprosthetic design. Methods: A total of 96 consecutive patients who underwent endovascular repair of thoracic (5) and abdominal (91) aortic aneurysms (April 1998-December 1999) were included in this study. Data were collected prospectively Gadolinium-enhanced MRA was used preoperatively in place of conventional imaging if renal insufficiency or a history of severe contrast reaction was present. The control group underwent conventional imaging. Endografts used included Ancure, AneuRx, and Talent. Results: Fourteen patients (14.6%) had their endografts designed solely with MRA. Intraoperative access failure; proximal and distal extensions (unplanned); conversion to open, aborted procedures; and endoleaks occurred with equal frequency in both the MRA-designed and control groups (16.7% vs 18.3%, respectively; P = .33). Despite baseline renal insufficiency, there was no significant rise in the creatinine level after endograft implantation in patients with an MRA design (preoperative level, 1.8; postoperative level, 1.9; P = .5). Conclusion: MRA may be successfully used as the sole modality for aortic endograft design. The use of MRA for this purpose is noninvasive and minimizes nephrotoxic risk.
引用
收藏
页码:488 / 494
页数:7
相关论文
共 16 条
  • [1] Systemic gadolinium toxicity in patients with renal insufficiency and renal failure: Retrospective analysis of an initial experience
    Arsenault, TM
    King, BF
    Marsh, JW
    Goodman, JA
    Weaver, AL
    Wood, CP
    Ehman, RL
    [J]. MAYO CLINIC PROCEEDINGS, 1996, 71 (12) : 1150 - 1154
  • [2] Beebe HG, 1997, J ENDOVASC SURG, V4, P111, DOI 10.1583/1074-6218(1997)004<0111:IMFAE>2.0.CO
  • [3] 2
  • [4] BETTMANN MA, 1997, ABRAMS ANGIOGRAPHY, P22
  • [5] Magnetic resonance imaging and MR angiography of endoluminally treated abdominal aortic aneurysms
    Engellau, L
    Larsson, EM
    Albrechtsson, U
    Jonung, T
    Ribbe, E
    Thorne, J
    Zdanowski, Z
    Norgren, L
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (03) : 212 - 219
  • [6] Three-dimensional MR angiography of a nitinol-based abdominal aortic stent graft: assessment of heating and imaging characteristics
    Hilfiker, PR
    Quick, HH
    Pfammatter, T
    Schmidt, M
    Debatin, JF
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (09) : 1775 - 1780
  • [7] PRETREATMENT WITH CORTICOSTEROIDS TO PREVENT ADVERSE REACTIONS TO NONIONIC CONTRAST-MEDIA
    LASSER, EC
    BERRY, CC
    MISHKIN, MM
    WILLIAMSON, B
    ZHEUTLIN, N
    SILVERMAN, JM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (03) : 523 - 526
  • [8] Adverse reactions to gadolinium contrast media: A review of 36 cases
    Murphy, KJ
    Brunberg, JA
    Cohan, RH
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) : 847 - 849
  • [9] Nasim A, 1998, BRIT J SURG, V85, P641
  • [10] Parodi J C, 1991, Ann Vasc Surg, V5, P491, DOI 10.1007/BF02015271