New technologies for respiratory assist

被引:36
作者
Matheis, G [1 ]
机构
[1] NovaLung, D-72379 Hechingen, Germany
来源
PERFUSION-UK | 2003年 / 18卷 / 04期
关键词
D O I
10.1191/0267659103pf684oa
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
'The artificial lung especially has lingered behind progress with artificial hearts and ventricular assist devices, not because the need for lungs has not been recognized, but because we have not had a full understanding of the engineering problems and the unique material requirements until recent years.'(1) Brack Hattler, MD PhD. The development from the first clinical use of haemodialysis over five decades ago to widespread chronic treatment took more than two decades. The histories of other artificial organ technologies, such as artificial hearts, follow similar long development paths. For five decades, due to a lack of technology, artificial lungs have been limited to use with a heart-lung machine for cardiopulmonary bypass (CPB) or extracorporeal membrane oxygenation (ECMO). The advent of pumpless biocompatible artificial lungs will open new treatment options for patients with acute or chronic lung failure.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 31 条
[1]   Derivation of type II alveolar epithelial cells from murine embryonic stem cells [J].
Ali, NN ;
Edgar, AJ ;
Samadikuchaksaraei, A ;
Timson, CM ;
Romanska, HM ;
Polak, JM ;
Bishop, AE .
TISSUE ENGINEERING, 2002, 8 (04) :541-550
[2]  
*AM LUNG ASS, 2000, CHRON OBSTR PULM DIS
[3]   Small intrapulmonary artery lung prototypes - Mathematical modeling of gas transfer [J].
Baskaran, H ;
Nodelman, V ;
Ultman, JS ;
Richard, RB ;
Panol, G ;
High, KM ;
Snider, MT .
ASAIO JOURNAL, 1996, 42 (05) :M597-M603
[4]   Feasibility of a photosynthetic artificial lung [J].
BasuDutt, S ;
Fandino, MR ;
Salley, SO ;
Thompson, IM ;
Whittlesey, GC ;
Klein, MD .
ASAIO JOURNAL, 1997, 43 (04) :279-283
[5]   Hemodynamic effects of attachment modes and device design of a thoracic artificial lung [J].
Boschetti, F ;
Perlman, CE ;
Cook, KE ;
Mockros, LF .
ASAIO JOURNAL, 2000, 46 (01) :42-48
[6]  
CAPPELLETTI DD, 1996, J EXTRA-CORP TECHNOL, V28, P6
[7]   Arteriovenous extracorporeal carbon dioxide removal - A mathematical model and experimental evaluation [J].
Conrad, SA ;
Brown, EG ;
Grier, LR ;
Baier, J ;
Blount, J ;
Heming, T ;
Zwischenberger, JB ;
Bidani, A .
ASAIO JOURNAL, 1998, 44 (04) :267-277
[8]   Feasibility of a pumpless extracorporeal respiratory assist device [J].
De Somer, F ;
Van Belleghem, Y ;
Foubert, L ;
Caes, F ;
François, K ;
Dubrulle, F ;
Van Nooten, G .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1999, 18 (10) :1014-1017
[9]  
Fazzalari F L, 1994, ASAIO J, V40, pM728, DOI 10.1097/00002480-199407000-00094
[10]   Design of an artificial lung compliance chamber for pulmonary replacement [J].
Haft, JW ;
Bull, JL ;
Rose, R ;
Katsra, J ;
Grotberg, JB ;
Bartlett, RH ;
Hirschl, RB .
ASAIO JOURNAL, 2003, 49 (01) :35-40