Amperometric uric acid sensors based on polyelectrolyte multilayer films

被引:98
作者
Hoshi, T [1 ]
Saiki, H [1 ]
Anzai, J [1 ]
机构
[1] Tohoku Univ, Grad Sch Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9808578, Japan
关键词
polyelectrolyte; uric acid sensors; amperometric measurement;
D O I
10.1016/S0039-9140(03)00303-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Uricase (UOx) and polyelectrolyte were used for preparation of a permselective multilayer film and enzyme multilayer films on a platinum (Pt) electrode, allowing the detection of uric acid amperometrically. The polyelectrolyte multilayer (PEM) film composed of poly(allylamine) (PAA) and poly(vinyl sulfate) (PVS) were prepared via layer-by-layer assembly on the electrode, functioning as H2O2-selective film. After deposition of the permselective film (PAA/ PVS)(2)PAA, UOx and PAA were deposited via layer-by-layer sequential deposition up to 10 UOx layers to prepare amperometric sensors for uric acid. Current response to uric acid was recorded at +0.6 V vs. Ag/AgCl to detect H2O2 produced from the enzyme reaction. The response current increased with increasing the number of UOx layers. Even in the presence of ascorbic acid, uric acid can be detected over the concentration range 10(-6)-10(-3) M. The response current and deposited amount of UOx were affected by deposition bath pH and the addition of salt. The deposition of PAA/UOx film prepared in 2 mg ml(-1) solution (pH 11) of PAA with NaCI (8 mg ml(-1)) and 0.1 mg ml(-1) solution (pH 8.5) of UOx with berate (100 mM) resulted in an electrode which shows the largest response to uric acid. The response of the sensor to uric acid was decreased by 40% from the original activity after 30 days. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:363 / 368
页数:6
相关论文
共 20 条
[1]   Elimination of ascorbate interference of glucose biosensors by use of enzyme multilayers composed of avidin and biotin-labeled glucose oxidase and ascorbate oxidase [J].
Anzai, J ;
Takeshita, H ;
Hoshi, T ;
Osa, T .
DENKI KAGAKU, 1995, 63 (12) :1141-1142
[2]   Construction of multilayer thin films containing avidin by a layer-by-layer deposition of avidin and poly(anion)s [J].
Anzai, J ;
Hoshi, T ;
Nakamura, N .
LANGMUIR, 2000, 16 (15) :6306-6311
[3]   Assembly of alternating polyelectrolyte and protein multilayer films for immunosensing .2. [J].
Caruso, F ;
Niikura, K ;
Furlong, DN ;
Okahata, Y .
LANGMUIR, 1997, 13 (13) :3427-3433
[4]   Protein multilayer formation on colloids through a stepwise self-assembly technique [J].
Caruso, F ;
Möhwald, H .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (25) :6039-6046
[5]  
DAAE LNW, 1983, SCAND J CLIN LAB INV, V43, P747
[6]   NOVEL, REAGENTLESS, AMPEROMETRIC BIOSENSOR FOR URIC-ACID BASED ON A CHEMICALLY-MODIFIED SCREEN-PRINTED CARBON ELECTRODE COATED WITH CELLULOSE-ACETATE AND URICASE [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1994, 119 (05) :833-840
[7]   EPIDEMIOLOGY OF GOUT AND HYPERURICEMIA - A LONG-TERM POPULATION STUDY [J].
HALL, AP ;
BARRY, PE ;
DAWBER, TR ;
MCNAMARA, PM .
AMERICAN JOURNAL OF MEDICINE, 1967, 42 (01) :27-&
[8]   Layer-by-layer self-assembly of glucose oxidase with a poly(allylamine)ferrocene redox mediator [J].
Hodak, J ;
Etchenique, R ;
Calvo, EJ ;
Singhal, K ;
Bartlett, PN .
LANGMUIR, 1997, 13 (10) :2708-2716
[9]   Selective permeation of hydrogen peroxide through polyelectrolyte multilayer films and its use for amperometric biosensors [J].
Hoshi, T ;
Saiki, H ;
Kuwazawa, S ;
Tsuchiya, C ;
Chen, Q ;
Anzai, J .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5310-5315
[10]   STUDIES ON URATE OXIDASE OF CANDIDA-UTILIS .2. SOME PHYSICAL AND CHEMICAL PROPERTIES OF PURIFIED ENZYME [J].
ITAYA, K ;
FUKUMOTO, J ;
YAMAMOTO, T .
AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1971, 35 (06) :813-&