Simplified injector flanges for the selected ion flow tube

被引:7
作者
Fishman, VN [1 ]
Grabowski, JJ [1 ]
机构
[1] Univ Pittsburgh, Dept Chem, Pittsburgh, PA 15260 USA
关键词
selected ion flow tube; SIFT; flowing afterglow; injector flange; Venturi inlet;
D O I
10.1016/S1387-3806(98)14040-X
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Dual hole-pattern injector flanges (Venturi inlets) for a selected ion flow tube:have been fabricated and tested in order to identify an optimum balance of efficient operational characteristics and simplicity of fabrication, along with reproducible assembly. The diagnostic measurements for each configuration addressed: (a) ability to maintain pressure differences between ion selection and ion reaction regions; (b) ability to inject sufficient ions to carry out ion/molecule reaction studies; and (c) ability to not introduce turbulence in the reaction region of the flow tube. In addition, the sensitivity of these issues to different total gas flow and to partitioning of total flow between inner and outer injectors is considered. All hole-pattern injector configurations ever tried worked without requiring any adjusting. Importantly, extensive kinetic measurements of one ion/molecule reaction for many configurations, gas loads, and partitions, Indicate turbulence in the reaction region is never a problem for these injectors. An injector flange with a small total helium inlet area via 12 holes, in a planar surface, with the ion orifice slightly downstream of the helium inlet plane, has provided the best experimental data. (Int J Mass Spectrom 177 (1998) 175-186) (C) 1998 Elsevier Science B.V.
引用
收藏
页码:175 / 186
页数:12
相关论文
共 18 条
[1]   SELECTED ION FLOW TUBE (SIFT) - TECHNIQUE FOR STUDYING ION-NEUTRAL REACTIONS [J].
ADAMS, NG ;
SMITH, D .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1976, 21 (3-4) :349-359
[2]  
[Anonymous], 1961, Z ANGEW PHYSIK
[3]   ELECTRON BOMBARDMENT MOLECULAR BEAM DETECTOR [J].
BRINK, GO .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (07) :857-&
[4]   DIAGNOSTIC STUDIES OF VENTURI INLETS FOR FLOW REACTORS [J].
DUPEYRAT, G ;
ROWE, BR ;
FAHEY, DW ;
ALBRITTON, DL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1982, 44 (1-2) :1-18
[5]   ADVANCES IN FLOW REACTOR TECHNIQUES FOR THE STUDY OF GAS-PHASE ION CHEMISTRY [J].
GRAUL, ST ;
SQUIRES, RR .
MASS SPECTROMETRY REVIEWS, 1988, 7 (03) :263-358
[6]   H+ AND D+ IONS IN HE - OBSERVATIONS OF A RUNAWAY MOBILITY [J].
HOWORKA, F ;
FEHSENFELD, FC ;
ALBRITTON, DL .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1979, 12 (24) :4189-4197
[7]   PROTON-TRANSFER REACTIONS OF (C2H2)-H-(+.) - THE BOND-ENERGY D0(C2H-H) [J].
IRAQI, M ;
PETRANK, A ;
PERES, M ;
LIFSHITZ, C .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 100 :679-691
[8]   A SELECTED-ION FLOW TUBE-LASER INDUCED FLUORESCENCE INSTRUMENT FOR VIBRATIONALLY STATE-SPECIFIC ION-MOLECULE REACTIONS [J].
KATO, S ;
FROST, MJ ;
BIERBAUM, VM ;
LEONE, SR .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (10) :2808-2820
[9]   GAS-PHASE REACTIONS OF NEGATIVE-IONS WITH ALKYL NITRITES [J].
KING, GK ;
MARICQ, MM ;
BIERBAUM, VM ;
DEPUY, CH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1981, 103 (24) :7133-7140
[10]   MOBILITIES OF VARIOUS MASS-IDENTIFIED POSITIVE-IONS IN HELIUM AND ARGON [J].
LINDINGER, W ;
ALBRITTON, DL .
JOURNAL OF CHEMICAL PHYSICS, 1975, 62 (09) :3517-3522