Confirmatory reanalysis of incurred bioanalytical samples

被引:121
作者
Rocci, Mario L., Jr.
Devanarayan, Viswanath
Haughey, David B.
Jardieu, Paula
机构
[1] Prevalere Life Sci Inc, Dept Analyt Sci & Prod Dev, Whitesboro, NY 13492 USA
[2] Global Stat & Data Management, Abbott Labs, Parsippany, NJ USA
关键词
bioanalytical; incurred samples; LC/; MS/; MS; ELISA; immunoassay; reproducibility;
D O I
10.1208/aapsj0903040
中图分类号
R9 [药学];
学科分类号
1007 [药学];
摘要
Bioanalytical methods used to support the drug development process are validated to ensure that they function in the manner in which they are intended. "Incurred" or study samples can vary in their composition when compared with the standards and quality control samples used to validate the method and analyze these samples. During the 3rd American Association of Pharmaceutical Scientists(AAPS)/Food and Drug Administration(FDA) Bioanalytical Workshop, it was suggested that the reproducibility in the analysis of incurred samples be evaluated in addition to the usual prestudy validation activities performed. This manuscript provides recommendations concerning the number and types of samples that should be analyzed in such an evaluation, as well as the manner in which the resultant data should be analyzed. Suggestions as to follow-up activities and data reporting are also discussed. This approach is at best a beginning and is offered as a platform for future discussion, comments, and revision.
引用
收藏
页码:E336 / E343
页数:8
相关论文
共 14 条
[1]
BANSAL SB, 2006, BEST PRACTICES CHROM
[2]
A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) :337-340
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
*CAN HLTH MIN, 2003, NOT IND REM REQ 15 P
[5]
Canadian Health Ministry, 1996, GUID IND COND AN BIO
[6]
Canadian Health Ministry, 1992, GUID IND COND AN BIO
[7]
Recommendations for the bioanalytical method validation of ligand-binding assays to support pharmacokinetic assessments of macromolecules [J].
DeSilva, B ;
Smith, W ;
Weiner, R ;
Kelley, M ;
Smolec, JM ;
Lee, B ;
Khan, M ;
Tacey, R ;
Hill, H ;
Celniker, A .
PHARMACEUTICAL RESEARCH, 2003, 20 (11) :1885-1900
[8]
*E LIL CO NIH NCGC, 2005, TRANS VAL ASS
[9]
The minimum significant ratio: A statistical parameter to characterize the reproducibility of potency estimates from concentration-response assays and estimation by replicate-experiment studies [J].
Eastwood, BJ ;
Farmen, MW ;
Iversen, PW ;
Craft, TJ ;
Smallwood, JK ;
Garbison, KE ;
Delapp, NW ;
Smith, GF .
JOURNAL OF BIOMOLECULAR SCREENING, 2006, 11 (03) :253-261
[10]
[FDA CDER], 2001, GUID IND BIOAN METH