Optimization of shaded surface display for CT angiography

被引:8
作者
Addis, KA
Hopper, KD
Iyriboz, TA
Kasales, CJ
Liu, Y
Wise, SW
机构
[1] Penn State Univ, Dept Radiol, Hershey, PA 17033 USA
[2] Penn State Univ, Coll Med, Hershey, PA 17033 USA
关键词
angiography; technology; arteries; CT; computed tomography (CT); three-dimensional;
D O I
10.1016/S1076-6332(03)80641-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The authors performed this study to determine the optimum threshold for performing computed tomographic (Cf) angiography with shaded surface display (SSD). Materials and Methods. A dedicated phantom was developed with an 8-mm luminal diameter. Each of 19 vessels had stenoses ranging from 0% to 93.8%. Five blinded, experienced reviewers separately measured each vessel by using SSD with display thresholds of 50, 100, 150, and 200 HU. Results. For vessel diameters of 2 mm and larger, the best threshold value was, 100 HU. This yielded measurements within 2% of the actual diameter and produced no false occlusions. For vessels 1 mm in diameter, the best threshold remained 100 HU, but this threshold was significantly less accurate than the standard (P = .0001) and produced two false occlusions in 15 vessels. For vessels 0.5 mm in diameter, the best threshold was 50 HU, although this still produced measurements significantly less accurate than the gold standard (P = .036) and one false occlusion in 15 vessels. Conclusion. CT angiography with SSD and an optimized threshold value is a useful technique in vessels 1 mm and larger.
引用
收藏
页码:976 / 981
页数:6
相关论文
共 14 条
[1]   Helical CT angiography compared with arteriography in the detection of renal artery stenosis [J].
Beregi, JP ;
Elkohen, M ;
Deklunder, G ;
Artaud, D ;
Coullet, JM ;
Wattinne, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :495-501
[2]   CAROTID-ARTERY STENOSIS - A PROSPECTIVE COMPARISON OF CT ANGIOGRAPHY AND CONVENTIONAL ANGIOGRAPHY [J].
CUMMING, MJ ;
MORROW, IM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :517-523
[3]   A phantom study: Evaluation of renal artery stenosis using helical CT and 3D reconstructions [J].
Davros, WJ ;
Obuchowski, NA ;
Berman, PM ;
Zeman, RK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) :156-161
[4]   CT ANGIOGRAPHY - APPLICATION TO THE EVALUATION OF CAROTID-ARTERY STENOSIS [J].
DILLON, EH ;
VANLEEUWEN, MS ;
FERNANDEZ, MA ;
EIKELBOOM, BC ;
MALI, WPTM .
RADIOLOGY, 1993, 189 (01) :211-219
[5]  
Dix JE, 1997, AM J NEURORADIOL, V18, P409
[6]  
Elkohen M, 1996, J HYPERTENS, V14, P525
[7]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[8]   Optimization of parameters for the detection of cerebral aneurysms: CT angiography of a model [J].
Kallmes, DF ;
Evans, AJ ;
Woodcock, RJ ;
Omary, RA ;
Dix, JE ;
McNulty, BC ;
Holder, CA ;
Dion, JE .
RADIOLOGY, 1996, 200 (02) :403-405
[9]   COMPUTED TOMOGRAPHIC ANGIOGRAPHY FOR THE EVALUATION OF CAROTID-ARTERY STENOSIS [J].
LECLERC, X ;
GODEFROY, O ;
PRUVO, JP ;
LEYS, D .
STROKE, 1995, 26 (09) :1577-1581
[10]   DETECTION AND ASSESSMENT OF INTRACRANIAL ANEURYSMS - VALUE OF CT ANGIOGRAPHY WITH SHADED-SURFACE DISPLAY [J].
LIANG, EY ;
CHAN, M ;
HSIANG, JHK ;
WALKDEN, SB ;
POON, WS ;
LAM, WWM ;
METREWELI, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1497-1502