Supraventricular arrhythmias in children and young adults with implantable cardioverter defibrillators

被引:32
作者
Love, BA
Barrett, KS
Alexander, ME
Bevilacqua, LM
Epstein, MR
Triedman, JK
Walsh, EP
Berul, CI
机构
[1] Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USA
关键词
implantable defibrillator; supraventricular tachycardia; congenital heart defects; children;
D O I
10.1046/j.1540-8167.2001.01097.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
SVT in Pediatric ICD Recipients. Introduction: Rapidly conducted supraventricular tachycardias (SVTs) can lead to inappropriate device therapy in implantable cardioverter defibrillator (ICD) patients. We sought to determine the incidence of SVTs and the occurrence of inappropriate ICD therapy due to SVT in a pediatric and young adult population. Methods and Results: We undertook a retrospective review of clinical course, Holter monitoring, and ICD interrogations of patients receiving ICD follow-up at our institution between March 1992 and December 1999. Of 81 new ICD implantations, 54 eligible patients (median age 16.5 years, range 1 to 48) were identified. Implantation indications included syncope and/or spontaneous/inducible ventricular arrhythmia with congenital heart disease (30), long QT syndrome (9), structurally normal heart (ventricular tachycardia/ventricular fibrillation [VT/VF]) (7), and cardiomyopathies (7). Sixteen patients (30%) received a dual-chamber ICD. SVT was recognized in 16 patients, with 12 of 16 having inducible or spontaneous atrial tachycardias. Eighteen patients (33%) received greater than or equal to1 appropriate shock(s) for VTNF; 8 patients (15%) received inappropriate therapy for SVT. Therapies were altered after an inappropriate shock by increasing the detection time or rate and/or increasing beta-blocker dosage. No single-chamber ICD was initially programmed with detection enhancements, such as sudden onset, rate stability, or QRS discriminators. Only one dual-chamber defibrillator was programmed with an atrial discrimination algorithm. Appropriate ICD therapy was not withheld due to detection parameters or SVT discrimination programming. Conclusion: SVT in children and young adults with ICDs is common. Inappropriate shocks due to SVT can be curtailed even without dual-chamber devices or specific SVT discrimination algorithms.
引用
收藏
页码:1097 / 1101
页数:5
相关论文
共 32 条
[1]   Value of programmed ventricular stimulation in patients with congenital heart disease [J].
Alexander, ME ;
Walsh, EP ;
Saul, JP ;
Epstein, MR ;
Triedman, JK .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (08) :1033-1044
[2]   Prospective evaluation of new and old criteria to discriminate between supraventricular and ventricular tachycardia in implantable defibrillators [J].
Barold, HS ;
Newby, KH ;
Tomassoni, G ;
Kearney, M ;
Brandon, J ;
Natale, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (07) :1347-1355
[3]  
BERUL CI, 2001, CARDIAC ARRHYTHMIAS, P319
[4]   Comparison of therapy detection times between implantable cardioverter defibrillators with standard dual- and single-chamber pacing [J].
Capucci, A ;
Villani, GQ ;
Groppi, F ;
Aschieri, D ;
Hull, M ;
Kuehl, M .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1999, 3 (04) :329-333
[5]   The potential for inappropriate ventricular tachycardia confirmation using the Intracardiac Electrogram (EGM) Width Criterion [J].
Duru, F ;
Schönbeck, M ;
Lüscher, TF ;
Candinas, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (07) :1039-1046
[6]   Use of a single coil transvenous electrode with an abdominally placed implantable cardioverter defibrillator in children [J].
Fischbach, PS ;
Law, IH ;
Dick, M ;
Leroy, S ;
Mosca, RS ;
Serwer, GA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (05) :884-887
[7]   THE LONG QT SYNDROME IN CHILDREN - AN INTERNATIONAL STUDY OF 287 PATIENTS [J].
GARSON, A ;
DICK, M ;
FOURNIER, A ;
GILLETTE, PC ;
HAMILTON, R ;
KUGLER, JD ;
VANHARE, GF ;
VETTER, V ;
VICK, GW .
CIRCULATION, 1993, 87 (06) :1866-1872
[8]   A new defibrillator discrimination algorithm utilizing electrogram morphology analysis [J].
Gold, MR ;
Hsu, W ;
Marcovecchio, AF ;
Olsovsky, MR ;
Lang, DJ ;
Shorofsky, SR .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01) :179-182
[9]   ELECTROCARDIOGRAPHICALLY DOCUMENTED UNNECESSARY, SPONTANEOUS SHOCKS IN 241 PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS [J].
GRIMM, W ;
FLORES, BF ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1667-1673
[10]   Five-year experience with implantable defibrillators in children [J].
Hamilton, RM ;
Dorian, P ;
Gow, RM ;
Williams, WG .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (07) :524-&