Laboratory control of oral anticoagulant therapy: preservation of prothrombin time specimens using a polypropylene collection system

被引:11
作者
Ridyard, J
Bhavnani, M
Seal, LH
机构
[1] Royal Albert Edward Infirm, Dept Haematol, Wigan WN1 2NN, England
[2] Manchester Metropolitan Univ, Dept Biol Sci, Manchester M15 6BH, Lancs, England
来源
CLINICAL AND LABORATORY HAEMATOLOGY | 1998年 / 20卷 / 06期
关键词
prothrombin time; polypropylene tubes; oral anticoagulant therapy;
D O I
10.1046/j.1365-2257.1998.00164.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous studies have shown a marked time and temperature dependent shortening of the prothrombin time (PT) when brood is exposed to borosilicate (glass) or siliconized borosilicate tubes. Current recommendations are that samples for PT estimation should be tested within 2 h of collection. in this study using polypropylene collection tubes, blood obtained from 30 patients on oral anticoagulant therapy showed no significant change in International Normalized Ratio (INR) value after 24 h storage - either at 4 degrees C or room temperature, After 48 h, changes in INR values from refrigerated samples were still clinically insignificant. After 48 h storage at room temperature, however, a minority of samples showed an increase in INR value which may be of clinical importance. The range of INRs studied was 1.0-9.1. In a second evaluation, replicate specimens from 22 orally anticoagulated patients with INRs ranging from 1.0 to 9.6 showed no significant change after 24 h at either temperature even when samples had been subjected to 30 min of gentle agitation prior to storage and analysis. Overall, the results indicate that when polypropylene collection tubes are used, prothrombin time specimens can be successfully preserved for up to 24 h at room temperature or up to 48 h when refrigerated.
引用
收藏
页码:369 / 372
页数:4
相关论文
共 9 条
[1]   Reliability of delayed INR determination: Implications for decentralized anticoagulant care with off-site blood sampling [J].
Baglin, T ;
Luddington, R .
BRITISH JOURNAL OF HAEMATOLOGY, 1997, 96 (03) :431-434
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Dacie JV, 1995, PRACTICAL HAEMATOLOG
[4]  
Hernandez AG, 1997, BRIT J HAEMATOL, V98, P781
[5]   INHIBITION OF COLD-PROMOTED ACTIVATION OF THE PROTHROMBIN TIME STUDIES OF NEW SILICONIZED BOROSILICATE COLLECTION TUBES IN NORMALS AND PATIENTS RECEIVING WARFARIN [J].
PALMER, RN ;
GRALNICK, HR .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1985, 83 (04) :492-494
[6]  
PALMER RN, 1982, BLOOD, V59, P38
[7]  
THOMSON JM, 1983, CLIN LAB HAEMATOL, V5, P413
[8]  
Vadher BD, 1997, BRIT J HAEMATOL, V97, P936
[9]  
VANDENBESSELAAR AM, 1983, THROMB DIATH HAEMO, V36, P230