Multiplexed microsphere-based flow cytometric immunoassays for human cytokines

被引:81
作者
Kellar, KL [1 ]
Douglass, JP [1 ]
机构
[1] Ctr Dis Control & Prevent, Biotechnol Core Facil Branch, Sci Resources Program, Natl Ctr Infect Dis, Atlanta, GA 30333 USA
关键词
fluorescent microspheres; multiplexed immunoassays; microsphere-based flow cytometric assays; luminex;
D O I
10.1016/S0022-1759(03)00248-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cytokines play a pivotal role in the regulation of immunologic, hematologic and wound-healing processes. They function to stimulate as well as inhibit the proliferation, differentiation and maturation of a variety of cell types. Thus, their functions are pleiotropic as well as interdependent to the extent that any cytokine may have effects that are synergistic or antagonistic with other cytokines. Cytokines also display redundancy when one mimics the functions of others. These characteristics imply that measuring the levels of one cytokine in a biologic system provides only a fraction of the information that is relevant to the existing physiologic state. A more realistic indication of the complexity of cellular interactions would include measurements of multiple cytokines at any time point. One method of multiplexed analysis can be performed by capture of the cytokines on an array of fluorescent microspheres for quantitation by flow cytometry. This technology has been applied to a variety of biomolecules, but simultaneous quantitation of multiple cytokines in a small sample volume has become rapid, inexpensive, reliable and informative. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:277 / 285
页数:9
相关论文
共 11 条
[1]  
BOSCATO LM, 1988, CLIN CHEM, V34, P27
[2]   Flow cytometric microsphere-based immunoassay:: Analysis of secreted ctytokines in whole-blood samples from asthmatics [J].
Camilla, C ;
Mély, L ;
Magnan, A ;
Casano, B ;
Prato, S ;
Debono, S ;
Montero, F ;
Defoort, JP ;
Martin, M ;
Fert, V .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2001, 8 (04) :776-784
[3]   Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay [J].
Carson, RT ;
Vignali, DAA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) :41-52
[4]  
Chen R, 1999, CLIN CHEM, V45, P1693
[5]  
DEGROOTE D, 1998, EUR CLIN LAB, V17, P12
[6]   The influence of naturally occurring heterophilic anti-immunoglobulin antibodies on direct measurement of serum proteins using sandwich ELISAs [J].
Hennig, C ;
Rink, L ;
Fagin, U ;
Jabs, WJ ;
Kirchner, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 235 (1-2) :71-80
[7]  
Kaplan IV, 1999, CLIN CHEM, V45, P616
[8]  
Kellar KL, 2001, CYTOMETRY, V45, P27, DOI 10.1002/1097-0320(20010901)45:1<27::AID-CYTO1141>3.0.CO
[9]  
2-I
[10]   Multiplexed microsphere-based flow cytometric assays [J].
Kellar, KL ;
Iannone, MA .
EXPERIMENTAL HEMATOLOGY, 2002, 30 (11) :1227-1237