Interobserver and intraobserver reproducibility of peripheral blood and oxygen pressure measurements in the assessment of lower extremity arterial disease

被引:86
作者
de Graaff, J
Ubbink, DT
Legemate, DA
de Haan, RJ
Jacobs, MJHM
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Vasc Surg, NL-1100 DE Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol, NL-1100 DE Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Biostat, NL-1100 DE Amsterdam, Netherlands
关键词
D O I
10.1067/mva.2001.108011
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Peripheral blood pressure measurements play a prominent role in the diagnosis and follow-up of patients with peripheral vascular diseases. Toe pressure of the hallux (TP1) and second toe (TP2) and transcutaneous oxygen pressure (TCPO2) measurements are becoming more important. The ankle/brachial pressure index (ABPI) is known to be a reliable parameter, but the toe pressure and TCPO2 are evaluated less thoroughly. Therefore, we evaluated the reproducibility of TP1, TP2, TCPO2, ABPI, ankle pressure (AP), and brachial pressure (BP). Patients and Methods: In 54 patients with various stages of peripheral vascular disease, the intraobserver and interobserver reproducibility of BP, AP, ABPI, TPL, TP2, and TCPO2 was investigated by calculating the repeatability coefficient (RC) and the intraclass correlation coefficient (ICC) and by using Bland-Altman plots. Results: The intraobserver and interobserver reproducibility at 1 day and after 1 week of BP, AP, ABPI, and TP1 was substantial and comparable (ICC range, 0.80-0.99), except for the Br after 1 week. The TP2 and TCPO2 were less reproducible (ICC range, 0.62-0.98). The interobserver RC of BP was 31 mm Hg; of AP, 44 mm Hg; of ABPI, 27%; of TPL, 41 mm Hg; of TP2, 67 mm Hg; and of TCPO2; 30 mm Hg. The difference plot showed that the observer variability was equally distributed across the range of pressure in all measurements. Conclusion: The BP, AP, ABPI, and TP1 have a substantial intraobserver and interobserver reproducibility, whereas TP2 and TCPO2 show worse reproducibility Especially when low values (or values around a cutoff value) are measured, the RC should be taken into account, and repetition of the measurement is advocated.
引用
收藏
页码:1033 / 1040
页数:8
相关论文
共 33 条
[1]   PROGNOSTIC VALUE OF SYSTOLIC ANKLE AND TOE BLOOD-PRESSURE LEVELS IN OUTCOME OF DIABETIC FOOT ULCER [J].
APELQVIST, J ;
CASTENFORS, J ;
LARSSON, J ;
STENSTROM, A ;
AGARDH, CD .
DIABETES CARE, 1989, 12 (06) :373-378
[2]  
BAKER JD, 1981, SURGERY, V89, P134
[3]   INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY [J].
BARTKO, JJ .
PSYCHOLOGICAL REPORTS, 1966, 19 (01) :3-&
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   PEDAL BLOOD-FLOW AND TRANS-CUTANEOUS PO2 IN NORMAL SUBJECTS AND IN PATIENTS SUFFERING FROM SEVERE ARTERIAL OCCLUSIVE DISEASE [J].
BONGARD, O ;
KRAHENBUHL, B .
CLINICAL PHYSIOLOGY, 1984, 4 (05) :393-401
[6]   TcPO2 as an accurate predictor of therapy in limb salvage [J].
Bunt, TJ ;
Holloway, GA .
ANNALS OF VASCULAR SURGERY, 1996, 10 (03) :224-227
[7]   DIGITAL SYSTOLIC PRESSURES IN LOWER LIMB IN ARTERIAL DISEASE [J].
CARTER, SA ;
LEZACK, JD .
CIRCULATION, 1971, 43 (06) :905-&
[8]  
CARTER SA, 1973, SCAND J CLIN LAB INV, V31, P239
[9]  
CASPARY L, 1993, VASA-J VASCULAR DIS, V22, P129
[10]  
Creutzig A, 1992, Vasa Suppl, V35, P32