Combined use of off-pump techniques and a sutureless proximal aortic anastomotic device reduces cerebral microemboli generation during coronary artery bypass grafting

被引:24
作者
Scarborough, JE
White, W
Derilus, FE
Mathew, JP
Newman, MF
Landolfo, KP
机构
[1] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Anesthesiol, Durham, NC 27710 USA
关键词
D O I
10.1016/S0022-5223(03)01039-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Intraoperative cerebral microemboli are associated with the development of postoperative stroke and neurocognitive decline in patients undergoing coronary artery bypass grafting. Although cardiopulmonary bypass is responsible for the generation of a significant number of such emboli, the elimination of cardiopulmonary bypass alone has not been conclusively shown to improve neurocognitive outcome. The current study was performed to determine the effects of combined off-pump coronary artery bypass grafting and sutureless proximal aortic anastomotic techniques on the generation of intraoperative cerebral microemboli compared with standard coronary artery bypass grafting techniques of cardiopulmonary bypass and hand-sewn proximal anastomoses. Methods: Fifty-three patients underwent off-pump coronary artery bypass grafting by using the sutureless Symmetry aortic connector device (St Jude Medical, St Paul, Minn) for all proximal anastomoses. Eighteen of these patients received intraoperative transcranial Doppler ultrasonography to determine right- and left-sided cerebral microembolic counts. These results were compared with those obtained from a similar group of 17 patients undergoing standard coronary artery bypass grafting, in whom cardiopulmonary bypass and hand-sewn proximal anastomoses were used. Results: Our use of the proximal anastomotic device in patients undergoing coronary artery bypass grafting was safe, with no aortic complications, postoperative strokes, or in-hospital deaths. Microembolic counts to both the right and left cerebral circulation were significantly reduced in the patients undergoing off-pump coronary artery bypass grafting (right = 21.9 +/- 20.7 emboli, left = 24.9 +/- 19.2 emboli) compared with those in patients undergoing standard coronary artery bypass grafting (right = 181.6 +/- 85.3, left = 189.9 +/- 60.401, P < .0001). Conclusions: Our use of a sutureless proximal anastomotic device during off-pump coronary artery bypass grafting is safe and significantly decreases cerebral micro-embolism when compared with standard coronary artery bypass grafting with cardiopulmonary bypass and hand-sewn anastomoses. Long-term follow-up is needed to determine the effects of this technical strategy on neurocognitive outcome.
引用
收藏
页码:1561 / 1567
页数:7
相关论文
共 23 条
[1]   Evidence for improved cerebral function after minimally invasive bypass surgery [J].
BhaskerRao, B ;
VanHimbergen, D ;
Edmonds, HL ;
Jaber, S ;
Ali, AT ;
Pagni, S ;
Koenig, S ;
Spence, PA .
JOURNAL OF CARDIAC SURGERY, 1998, 13 (01) :27-31
[2]   Stroke during coronary bypass surgery: principal role of cerebral macroemboli [J].
Borger, MA ;
Ivanov, J ;
Weisel, RD ;
Rao, V ;
Peniston, CM .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 19 (05) :627-632
[3]   Coronary artery bypass performed without the use of cardiopulmonary bypass is associated with reduced cerebral microemboli and improved clinical results [J].
Bowles, BJ ;
Lee, JD ;
Dang, CR ;
Taoka, SN ;
Johnson, EW ;
Lau, EM ;
Nekomoto, K .
CHEST, 2001, 119 (01) :25-30
[4]   Cardiotomy suction: A major source of brain lipid emboli during cardiopulmonary bypass [J].
Brooker, RF ;
Brown, WR ;
Moody, DM ;
Hammon, JW ;
Reboussin, DM ;
Deal, DD ;
Ghazi-Birry, HS ;
Stump, DA .
ANNALS OF THORACIC SURGERY, 1998, 65 (06) :1651-1655
[5]   BRAIN EMBOLIC PHENOMENA ASSOCIATED WITH CARDIOPULMONARY BYPASS [J].
CHALLA, VR ;
MOODY, DM ;
TROOST, BT .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 1993, 117 (1-2) :224-231
[6]   MICROEMBOLI DURING CORONARY-ARTERY BYPASS-GRAFTING - GENESIS AND EFFECT AN OUTCOME [J].
CLARK, RE ;
BRILLMAN, J ;
DAVIS, DA ;
LOVELL, MR ;
PRICE, TRP ;
MAGOVERN, GJ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (02) :249-258
[7]   Neuromonitoring and neurocognitive outcome in off-pump versus conventional coronary bypass operation [J].
Diegeler, A ;
Hirsch, R ;
Schneider, F ;
Schilling, LO ;
Falk, V ;
Rauch, T ;
Mohr, FW .
ANNALS OF THORACIC SURGERY, 2000, 69 (04) :1162-1166
[8]  
ENGLEMAN DT, 1999, HEART SURG FORUM, V2, P242
[9]  
HAMMEKE TA, 1988, J THORAC CARDIOV SUR, V96, P326
[10]   Risk factors and solutions for the development of neurobehavioral changes after coronary artery bypass grafting [J].
Hammon, JW ;
Stump, DA ;
Kon, ND ;
Cordell, AR ;
Hudspeth, AS ;
Oaks, TE ;
Brooker, RF ;
Rogers, AT ;
Hilbawi, R ;
Coker, LH ;
Troost, BT .
ANNALS OF THORACIC SURGERY, 1997, 63 (06) :1613-1618