Aseptic insertion of central venous lines to reduce bacteraemia The Central Line Associated Bacteraemia in NSW Intensive Care Units (CLAB ICU) Collaborative

被引:29
作者
Burrell, Anthony R. [1 ,2 ]
McLaws, Mary-Louise [3 ]
Murgo, Margherita [2 ]
Calabria, Eda [2 ]
Pantle, Annette C. [2 ]
Herkes, Robert [1 ,4 ]
机构
[1] NSW Dept Hlth, Intens Care Coordinat & Monitoring Unit, NSW Intens Care Taskforce, Sydney, NSW, Australia
[2] Clin Excellence Commiss, Sydney, NSW, Australia
[3] Univ New S Wales, Sch Publ Hlth & Community Med, Sydney, NSW, Australia
[4] Royal Prince Alfred Hosp, Intens Care Serv, Sydney, NSW, Australia
关键词
BLOOD-STREAM INFECTIONS; CATHETER; PREVENTION; EDUCATION; DECREASE; PROGRAM; RISK;
D O I
10.5694/j.1326-5377.2011.tb03109.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To reduce the rate of central line-associated bacteraemia (CLAB). Design: A collaborative quality improvement project in intensive care units (ICUs) to promote aseptic insertion of central venous lines (CVLs). A checklist was used to record compliance with all aspects of aseptic CVL insertion, with maximal sterile barrier precautions for clinicians ("clinician bundle") and patients ("patient bundle"). CLAB was identified and reported using a standard surveillance definition. Participants and setting: Patients and clinicians in 37 ICUs in New South Wales, July 2007 - December 2008. Main outcome measures: Compliance with aseptic CVL insertion; rates of CLAB. Results: 10 890 CVL checklists were reviewed for compliance with the clinician and patient bundles: compliance with aseptic CVL insertion improved significantly (P < 0.001). The CLAB rate dropped from 3.0 to 1.2 per 1000 line-days (P < 0.001). Regardless of CVL type, the relative risk (RR) of CLAB in patients with CVLs inserted by clinicians not compliant with the clinician bundle was 1.62 times greater (95% CI, 1.1-2.4; P=0.018) than the RR with CVLs inserted by clinicians compliant with both bundles. Compliance with both the bundles was associated with a 50% reduction in risk of CLAB (RR, 0.5; 95% CI, 0.4-0.8; P=0.004). Conclusions: Compliance with all aspects of aseptic CVL insertion significantly reduces the risk of CLAB. A difficulty we experienced was that most ICUs lacked the organisation and staff to support quality improvement and audit. MJA 2011; 194: 583-587
引用
收藏
页码:583 / 587
页数:5
相关论文
共 26 条
[1]  
[Anonymous], 2005, MMWR Morb Mortal Wkly Rep
[2]   Eliminating catheter-related bloodstream infections in the intensive care unit [J].
Berenholtz, SM ;
Pronovost, PJ ;
Lipsett, PA ;
Hobson, D ;
Earsing, K ;
Farley, JE ;
Milanovich, S ;
Garrett-Mayer, E ;
Winters, BD ;
Rubin, HR ;
Dorman, T ;
Perl, TM .
CRITICAL CARE MEDICINE, 2004, 32 (10) :2014-2020
[3]   An Intensive Care Unit Quality Improvement Collaborative in Nine Department of Veterans Affairs Hospitals: Reducing Ventilator-Associated Pneumonia and Catheter-Related Bloodstream Infection Rates [J].
Bonello, Robert S. ;
Fletcher, Carol E. ;
Becker, William K. ;
Clutter, Kay L. ;
Arjes, Shelley L. ;
Cook, Jennifer J. ;
Petzel, Robert A. .
JOINT COMMISSION JOURNAL ON QUALITY AND PATIENT SAFETY, 2008, 34 (11) :639-645
[4]  
Carrer S, 2005, Minerva Anestesiol, V71, P197
[5]  
*CENTR LIN ASS BAC, CENTR VEN CATH INS C
[6]  
*CLIN EXC COMM, 2010, CENTR LIN ASS BACT N
[7]  
Drennan K, 2010, INTENSIVE CARE SAFET
[8]   Prevention of intravascular catheter infection [J].
Eggimann, Philippe .
CURRENT OPINION IN INFECTIOUS DISEASES, 2007, 20 (04) :360-369
[9]   Influence of insertion site on central venous catheter colonization and bloodstream infection rates [J].
Gowardman, John R. ;
Robertson, Iain K. ;
Parkes, Scott ;
Rickard, Claire M. .
INTENSIVE CARE MEDICINE, 2008, 34 (06) :1038-1045
[10]  
Hewson-Conroy Karena M, 2008, Crit Care Resusc, V10, P301