A body-fixed-sensor based analysis of compensatory trunk movements during unconstrained walking

被引:38
作者
Zijlstra, Agnes [1 ]
Goosen, Jon H. M. [2 ]
Verheyen, Cees C. P. M. [2 ]
Zijlstra, Wiebren [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, Groningen, Netherlands
[2] Weezenlanden Hosp, Isala Clin, Dept Orthoped Surg & Traumatol, Zwolle, Netherlands
关键词
body-fixed-sensors; segment orientation; accuracy; hip arthroplasty; Duchenne limp;
D O I
10.1016/j.gaitpost.2007.02.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This paper presents a body-fixed-sensor (BFS) based approach for quantifying compensatory trunk movements during unconstrained walking. Orientation of trunk segments was calculated by fusing low-pass filtered accelerometer data and high-pass filtered data from gyroscopes. To evaluate accuracy, frontal plane angular movements of the pelvis during different treadmill walking conditions were compared to results based on a high-accuracy camera system. Mean differences between the two methods remained within 0.31 degrees, standard deviations of differences within 1.4 degrees and error percentages within 17.7%. Correlations ranged from 0.87 to 0.99. To test, whether the method could discriminate between hip arthroplasty patients with and without compensatory trunk movements, the BFS based method was applied to patients and healthy controls during overground walking. Within a walking speed range of 0.40-1.10 m/s, the peak-to-peak amplitudes of trunk movements ranged from 5.7 degrees to 7.9 degrees in healthy subjects and from 13.5 degrees to 26.3 degrees versus 7.4 degrees to 13.8 degrees in patients with and without compensatory trunk movements, respectively. The presented BFS based approach can be used to assess spatio-temporal gait parameters and trunk movements and thus to objectively monitor gait function in hip arthroplasty patients in a clinical setting, (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 167
页数:4
相关论文
共 10 条
[1]   Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement [J].
Aminian, K ;
Trevisan, C ;
Najafi, B ;
Dejnabadi, H ;
Frigo, C ;
Pavan, E ;
Telonio, A ;
Cerati, F ;
Marinoni, EC ;
Robert, P ;
Leyvraz, PF .
GAIT & POSTURE, 2004, 20 (01) :102-107
[2]   The accuracy of measuring the kinematics of rising from a chair with accelerometers and gyroscopes [J].
Boonstra, MC ;
van der Slikke, RMA ;
Keijsers, NLW ;
van Lummel, RC ;
Malefijt, MCD ;
Verdonschot, N .
JOURNAL OF BIOMECHANICS, 2006, 39 (02) :354-358
[3]   Age, gender and speed effects on spinal kinematics during walking [J].
Crosbie, J ;
Vachalathiti, R ;
Smith, R .
GAIT & POSTURE, 1997, 5 (01) :13-20
[4]   Three-dimensional kinematics of the lumbar spine during treadmill walking at different speeds [J].
Feipel, V ;
De Mesmaeker, T ;
Klein, P ;
Rooze, M .
EUROPEAN SPINE JOURNAL, 2001, 10 (01) :16-22
[5]   THE SIGNIFICANCE OF THE TRENDELENBURG TEST [J].
HARDCASTLE, P ;
NADE, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (05) :741-746
[6]   The 'Entlastungsgang'.: A hip unloading gait as a new conservative therapy for hip pain in the adult [J].
Schröter, J ;
Güth, V ;
Overbeck, M ;
Rosenbaum, D ;
Winkelmann, W .
GAIT & POSTURE, 1999, 9 (03) :151-157
[7]   Angular movements of the pelvis and lumbar spine during self-selected and slow walking speeds [J].
Taylor, NF ;
Goldie, PA ;
Evans, OM .
GAIT & POSTURE, 1999, 9 (02) :88-94
[8]   Estimation of hip abduction moment based on body fixed sensors [J].
Zijlstra, W ;
Bisseling, R .
CLINICAL BIOMECHANICS, 2004, 19 (08) :819-827
[9]   Assessment of spatio-temporal parameters during unconstrained walking [J].
Zijlstra, W .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 92 (1-2) :39-44
[10]   Assessment of spatio-temporal gait parameters from trunk accelerations during human walking [J].
Zijlstra, W ;
Hof, AL .
GAIT & POSTURE, 2003, 18 (02) :1-10