Determination of the herbicide 4-chloro-2-methylphenoxyacetic acid and its main metabolite, 4-chloro-2-methylphenol in water and soil by liquid chromatography-electrospray tandem mass spectrometry

被引:74
作者
Pozo, O [1 ]
Pitarch, E [1 ]
Sancho, JV [1 ]
Hernández, F [1 ]
机构
[1] Univ Jaume 1, Expt Sci Dept, E-12071 Castellon De La Plana, Spain
关键词
soil analysis; water analysis; environmental analysis; pesticides; alkylphenols; phenoxyacetic acids;
D O I
10.1016/S0021-9673(01)01006-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive LC-electrospray tandem mass spectrometry method has been developed for the quantitation of 4-chloro-2-methylphenoxyacetic acid (MCPA) and 4-chloro-2-methylphenol in both water and soil samples. Soil samples were extracted in alkaline media and cleaned-up by solid-phase extraction with C-18 cartridges before LC-MS analysis. The selectivity and sensitivity offered by the triple quadrupole allowed the direct injection of the water samples rendering a sample throughput of around 100 samples per day, without any sample pretreatment, rendering for MCPA a limit of detection of 40 ng/l. In order to increase the method sensitivity, mainly for metabolite, a previous solid-phase extraction step was also performed. The method was validated by means of recovery experiments using fortified water and soil samples, obtaining satisfactory recoveries for both compounds in water and for MCPA in soil. The validated procedures can be used for the specific monitoring of residues of MCPA and its main metabolite in environmental samples, as ground and surface waters and soils, providing more selectivity and sensitivity than the current UV-based methodology. Besides, sample manipulation is greatly reduced in comparison to other GC-MS based methods which require a previous derivatization. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 85
页数:11
相关论文
共 35 条
[1]   Identification of pesticides by liquid chromatography particle beam mass spectrometry using electron ionization and chemical ionization [J].
Aguilar, C ;
Borrull, F ;
Marcé, RM .
JOURNAL OF CHROMATOGRAPHY A, 1998, 805 (1-2) :127-135
[2]   Comparison of automated on-line solid-phase extraction followed by liquid chromatography mass spectrometry with atmospheric pressure chemical ionization and particle beam mass spectrometry for the determination of a priority group of pesticides in environmental waters [J].
Aguilar, C ;
Ferrer, I ;
Borrull, F ;
Marcé, RM ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :147-163
[3]   Determination of naphthalene metabolites in human urine by liquid chromatography-mass spectrometry with electrospray ionization [J].
Andreoli, R ;
Manini, P ;
Bergamaschi, E ;
Mutti, A ;
Franchini, I ;
Niessen, WMA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 847 (1-2) :9-17
[4]  
BOBELDIJK I, 2000, 17 MONTR S LIQ CHROM
[5]   LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - A NEW WINDOW FOR ENVIRONMENTAL-ANALYSIS [J].
BROWN, MA ;
STEPHENS, RD ;
KIM, IS .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1991, 10 (10) :330-336
[6]   AUTOMATED ONLINE LIQUID-SOLID EXTRACTION FOLLOWED BY LIQUID CHROMATOGRAPHY-HIGH-FLOW PNEUMATICALLY ASSISTED ELECTROSPRAY MASS-SPECTROMETRY FOR THE DETERMINATION OF ACIDIC HERBICIDES IN ENVIRONMENTAL WATERS [J].
CHIRON, S ;
PAPILLOUD, S ;
HAERDI, W ;
BARCELO, D .
ANALYTICAL CHEMISTRY, 1995, 67 (09) :1637-1643
[7]   Simultaneous determination of base/neutral and acid herbicides in natural water at the part per trillion level [J].
D'Ascenzo, G ;
Gentili, A ;
Marchese, S ;
Marino, A ;
Perret, D .
CHROMATOGRAPHIA, 1998, 48 (7-8) :497-505
[8]   EVALUATION OF GRAPHITIZED CARBON-BLACK AS A SELECTIVE ADSORBENT FOR EXTRACTING ACIDIC ORGANIC-COMPOUNDS FROM WATER [J].
DICORCIA, A ;
MARCHESE, S ;
SAMPERI, R .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :163-174
[9]  
DIJKMAN E, 2001, UNPUB J CHROMATOGR A
[10]   FAST SCREENING METHOD FOR 8 PHENOXYACID HERBICIDES AND BENTAZONE IN WATER - OPTIMIZATION PROCEDURES FOR FLOW-INJECTION ANALYSIS-THERMOSPRAY TANDEM MASS-SPECTROMETRY [J].
GEERDINK, RB ;
KIENHUIS, PGM ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1993, 647 (02) :329-339