Fast multi-tau real-time software correlator for dynamic light scattering

被引:86
作者
Magatti, D
Ferri, F
机构
[1] Univ Insubria Como, Dipartimento Sci Chim Fis & Matemat, I-22100 Como, Italy
[2] Univ Insubria Como, INFM, I-22100 Como, Italy
关键词
D O I
10.1364/AO.40.004011
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a PC-based multi-tau software correlator suitable for processing dynamic light-scattering data. The correlator is based on a simple algorithm that was developed with the graphical programming language LabVIEW, according to which the incoming data are processed on line without any storage on the hard disk. By use of a standard photon-counting unit, a National Instruments Model 6602-PCI timer-counter, and a 550-MHz Pentium III personal computer, correlation functions can be worked out in full real-time overtime scales of similar to5 mus and in batch processing down to time scales of similar to 300 ns. The latter limit is imposed by the speed of data transfer between the counter and the PC's memory and thus is prone to be progressively reduced with future technological development. Testing of the correlator and evaluation of its performances were carried out by use of dilute solutions of calibrated polystyrene spheres. Our results indicate that the correlation functions are determined with such precision that the corresponding particle diameters can be recovered to within an accuracy of a few percent rms. (C) 2001 Optical Society of America.
引用
收藏
页码:4011 / 4021
页数:11
相关论文
共 20 条
[1]  
Berne B. J., 1976, DYNAMIC LIGHT SCATTE
[2]  
BROWN W, 1993, DYNAMIC LIGHT SCATT
[3]  
Cummins H.Z., 1974, PHOTON CORRELATION L
[4]  
CUMMINS HZ, 1974, PHOTON CORRELATION S
[5]   Data acquisition card for fluctuation correlation spectroscopy allowing full access to the detected photon sequence [J].
Eid, JS ;
Müller, JD ;
Gratton, E .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02) :361-368
[6]   DETERMINATION OF DIFFUSION COEFFICIENTS OF HAEMOCYANIN AT LOW CONCENTRATION BY INTENSITY FLUCTUATION SPECTROSCOPY OF SCATTERED LASER LIGHT [J].
FOORD, R ;
JAKEMAN, E ;
OLIVER, CJ ;
PIKE, ER ;
BLAGROVE, RJ ;
WOOD, E ;
PEACOCKE, AR .
NATURE, 1970, 227 (5255) :242-&
[7]  
FOORD R, 1969, IRE C P, V14
[8]  
Goodman J. W., 2000, STAT OPTICS
[9]   Systematic and statistical errors in correlation estimators obtained from various digital correlators [J].
Kojro, Z ;
Riede, A ;
Schubert, M ;
Grill, W .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (12) :4487-4496
[10]  
*NAT INSTR, 2000, MEAS AUT