Partial least-squares Fourier transform infrared spectrometric determination of methanol and ethanol by vapour-phase generation

被引:30
作者
Pérez-Ponce, A [1 ]
Rambla, FJ [1 ]
Garrigues, JM [1 ]
Garrigues, S [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
关键词
infrared spectrometry; flow analysis; partial least squares; vapour phase; methanol; ethanol;
D O I
10.1039/a800446c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A partial least-squares (PLS)-FTIR procedure is proposed for the direct determination of methanol and ethanol in liquid samples, based on vapour generation from small injected volumes of untreated samples, volatilized inside a Pyrex glass reactor, transported into a multi-pathlength cell with nitrogen carrier gas and then continuously measured by FTIR spectrometry, The spectra were processed using PLS regression, Several sets of standards and different wavenumber ranges were tested for calibration. A calibration set integrated by aqueous solutions of ethanol from 2.5 to 22.5% v/v and aqueous solutions of methanol from 0.5 to 3.5% v/v provided the lowest prediction errors. Average relative prediction errors for the PLS model of about 3% for ethanol and 2% for methanol were obtained for aqueous mixtures of the two compounds studied, with RSDs of 2.7 and 2,3%, respectively, calculated from four injections of 1 mu l of sample, providing the method with a sampling frequency of 69 h(-1). Results predicted by PLS-FTIR were compared with those found using a proportional equations approach. The method was applied to the determination of methanol and ethanol in high-level alcoholic beverages and cosmetic products, obtaining average recoveries of 107 +/- 6 and 98 +/- 2%, respectively.
引用
收藏
页码:1253 / 1258
页数:6
相关论文
共 37 条
[1]  
Andrade JM, 1996, FRESEN J ANAL CHEM, V355, P723
[2]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[3]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING PARTIAL LEAST-SQUARES AND ARTIFICIAL NEURAL NETWORKS BASED ON MIDINFRARED SPECTROSCOPY [J].
BHANDARE, P ;
MENDELSON, Y ;
PEURA, RA ;
JANATSCH, G ;
KRUSEJARRES, JD ;
MARBACH, R ;
HEISE, HM .
APPLIED SPECTROSCOPY, 1993, 47 (08) :1214-1221
[4]  
BLANCO M, 1995, APPL SPECTROSC, V49, P797
[5]   Simultaneous stopped-flow determination of paracetamol, acetylsalicylic acid and caffeine in pharmaceutical formulations by Fourier transform infrared spectrometry with partial least-squares data treatment [J].
Bouhsain, Z ;
Garrigues, S ;
delaGuardia, M .
ANALYST, 1996, 121 (12) :1935-1938
[6]  
CAI XY, 1995, HEWLETTPACKARD PEAK, V3, P10
[7]   Determination of weight percent oxygen in commercial gasoline: A comparison between FT-Raman, FT-IR, and dispersive near-IR spectroscopies [J].
Cooper, JB ;
Wise, KL ;
Welch, WT ;
Bledsoe, RR ;
Sumner, MB .
APPLIED SPECTROSCOPY, 1996, 50 (07) :917-921
[8]   Direct determination of ethanol and methanol in liquid samples by means of vapor phase-Fourier transform infrared spectrometry [J].
Garrigues, JM ;
Perez-Ponce, A ;
Garrigues, S ;
de la Guardia, M .
VIBRATIONAL SPECTROSCOPY, 1997, 15 (02) :219-228
[9]  
GARRIGUES JM, 1997, THESIS U VALENCIA
[10]   Multivariate calibrations in Fourier transform infrared spectrometry for prediction of kerosene properties [J].
Garrigues, S ;
Andrade, JM ;
delaGuardia, M ;
Prada, D .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :95-105