Digital breast tomosynthesis: Initial experience in 98 women with abnormal digital screening mammography

被引:354
作者
Poplack, Steven P.
Tosteson, Tor D.
Kogel, Christine A.
Nagy, Helene M.
机构
[1] Dartmouth Coll, Hitchcock Med Ctr, Dept Radiol, Lebanon, NH 03756 USA
[2] Dartmouth Med Sch, Dept Community & Family Med, Hanover, NH USA
[3] Norris Cotton Canc Ctr, Lebanon, NH USA
关键词
breast; breast cancer; digital mammography; screening; tomosynthesis;
D O I
10.2214/AJR.07.2231
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to compare the image quality of tomosynthesis with that of conventional mammography and to estimate the recall rate of screening when tomosynthesis is used in addition to mammography. MATERIALS AND METHODS. Women with an abnormal screening mammography were recruited sequentially. Consenting women underwent tomosynthesis of the affected breast corresponding to the views obtained with diagnostic mammography. The study radiologist compared the image quality, including lesion conspicuity and feature analysis, of tomosynthesis with diagnostic film-screen mammography and assessed the need for recall when tomosynthesis was added to digital screening mammography. Screening recalls were considered unnecessary when tomosynthesis did not show a corresponding abnormality or allowed definitely benign lesion characterization. Fisher's exact test was used to determine the association of equivalence and recall status with mammographic finding type. RESULTS. There were 99 digital screening recalls in 98 women. The image quality of tomosynthesis was equivalent (n = 51) or superior (n = 37) to diagnostic mammography in 89% (88/99). Finding type was significantly (p < 0.001) associated with equivalence. Approximately half-52/99 (52%)-of the findings would not have been recalled when digital screening mammography was supplemented with tomosynthesis. When adjusting for confounding conditions, the recall reduction was 40% (37/92). The likelihood of recall was also dependent on finding type (p = 0.004). CONCLUSION. Subjectively, tomosynthesis has comparable or superior image quality to that of film-screen mammography in the diagnostic setting, and it has the potential to decrease the recall rate when used adjunctively with digital screening mammography.
引用
收藏
页码:616 / 623
页数:8
相关论文
共 5 条
[1]  
Carney PA, 2003, ANN INTERN MED, V138, P168, DOI 10.7326/0003-4819-138-3-200302040-00008
[2]   Ten-year risk of false positive screening mammograms and clinical breast examinations [J].
Elmore, G ;
Barton, MB ;
Moceri, VM ;
Polk, S ;
Arena, PJ ;
Fletcher, SW .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (16) :1089-1096
[3]   Digital Tomosynthesis in breast imaging [J].
Niklason, LT ;
Christian, BT ;
Niklason, LE ;
Kopans, DB ;
Castleberry, DE ;
OpsahlOng, BH ;
Landberg, CE ;
Slanetz, PJ ;
Giardino, AA ;
Moore, R ;
Albagli, D ;
DeJule, MC ;
Fitzgerald, PF ;
Fobare, DF ;
Giambattista, BW ;
Kwasnick, RF ;
Liu, JQ ;
Lubowski, SJ ;
Possin, GE ;
Richotte, JF ;
Wei, CY ;
Wirth, RF .
RADIOLOGY, 1997, 205 (02) :399-406
[4]   Mammography in 53,803 women from the New Hampshire Mammography Network [J].
Poplack, SP ;
Tosteson, AN ;
Grove, MR ;
Wells, WA ;
Carney, PA .
RADIOLOGY, 2000, 217 (03) :832-840
[5]  
Smith Andrew, 2005, Radiol Manage, V27, P25